A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible

被引:0
|
作者
Gialain, Ivan Onone [1 ,2 ]
Gantier-Takano, Marlene Kasumi [1 ]
da Silva, Leonardo Folmer Rodrigues [1 ]
Roscoe, Marina Guimaraes [1 ]
Pinhata-Baptista, Otavio Henrique [3 ,4 ]
Meira, Josete Barbosa Cruz [1 ]
Fok, Alex Siu Lun [5 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biol, Av Prof Lineu Prestes,2227, BR-05508000 Sao Paulo, Brazil
[2] Univ Cuiaba, Cuiaba, Brazil
[3] Univ Sao Paulo, Mil Hosp Sao Paulo Area, Dent Div, Sao Paulo, Brazil
[4] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, Brazil
[5] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN USA
关键词
Mandible; Bone resorption; Dental implant; Dental prostheses; Occlusal load; ITI CONSENSUS REPORT; STRESS-DISTRIBUTION; SURROUNDING BONE; VALIDATION; DIAMETER; QUALITY; DESIGN; CROWNS; LENGTH;
D O I
10.2186/jpr.JPR_D_24_00003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible. Methods: Implants of different lengths (L = 4 or 6 mm) and diameters (0 = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 mu J/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold. Results: Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the 04.1 short implant with 3ca had a medium (0.8 <= PIBRri <= 1.0) or high (PIBRri>1.0) resorption risk. Conclusions: Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [31] Effect of peri-implantitis associated horizontal bone loss on stress distribution around dental implants - A 3D finite element analysis
    Gupta, Shipra
    Goyal, Parveen
    Jain, Ashish
    Chopra, Priyanka
    MATERIALS TODAY-PROCEEDINGS, 2020, 28 : 1503 - 1509
  • [32] How does the Number of Implants Affect Stress Distribution in Fibula Graft at the Posterior of the Mandible? A Finite Element Analysis
    Latifi, Fatemeh
    Tabrizi, Reza
    Hosseinikordkheili, Mohammadreza
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (02) : 304 - 312
  • [33] Influence of Abutment Design on Stress Distribution in Narrow Implants with Marginal Bone Loss: A Finite Element Analysis
    Yenigun, Serdar
    Ercal, Pinar
    Ozden-Yenigun, Elif
    Bulent Katiboglu, Ahmet
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (04) : 640 - 649
  • [34] Comparative evaluation of short or standard implants with different prosthetic designs in the posterior mandibular region: a three-dimensional finite element analysis study
    Qin, Siqi
    Gao, Zhi
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023, 26 (12) : 1499 - 1509
  • [35] Effect of bone mass density and alveolar bone resorption on stress in implant restoration of free-end edentulous posterior mandible: Finite element analysis of double-factor sensitivity
    Ye, Zhangyan
    Ye, Hao
    Wu, Yue
    Jiang, Zhengting
    Yao, Huiyu
    Xu, Xiaomin
    Zhang, Yitian
    Du, Weifeng
    Li, Wenshan
    Zheng, Yuwei
    Ye, Pengcheng
    Ding, Xi
    Wu, Lijun
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2024, 253
  • [36] Biomechanical Finite Element Analysis of Two Types of Short-Angled Implants Across Various Bone Classifications
    Ceddia, Mario
    Romasco, Tea
    De Bortoli Jr, Nilton
    Mello, Bruno Freitas
    Piattelli, Adriano
    Mijiritsky, Eitan
    Di Pietro, Natalia
    Trentadue, Bartolomeo
    MATERIALS, 2024, 17 (23)
  • [37] Biomechanical evaluation of implant-supported prosthesis with various tilting implant angles and bone types in atrophic maxilla: A finite element study
    Gumrukcu, Zeynep
    Korkmaz, Yavuz Tolga
    Korkmaz, Fatih Mehmet
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 86 : 47 - 54
  • [38] Influence of Implant Tilting and Length on the Biomechanics of Single-Tooth Restoration: A Finite Element Analysis in Atrophic Mandible
    Anitua, Eduardo
    Saez de Ibarra, Naiara Larrazabal
    Morales Martin, Inigo
    Saracho Rotaeche, Luis
    DENTISTRY JOURNAL, 2022, 10 (05)
  • [39] Does osteoporosis increase marginal bone loss around dental implants in the posterior of the maxilla?
    Tabrizi, R.
    Mousavi, F.
    Ghasemi, S.
    Ozkan, B. T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (07) : 964 - 968
  • [40] Influence of Bone and Dental Implant Parameters on Stress Distribution in the Mandible: A Finite Element Study
    Guan, Hong
    van Staden, Rudi
    Loo, Yew-Chaye
    Johnson, Newell
    Ivanovski, Saso
    Meredith, Neil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 866 - 876