A finite element study on the risk of bone loss around posterior short implants in an atrophic mandible

被引:0
|
作者
Gialain, Ivan Onone [1 ,2 ]
Gantier-Takano, Marlene Kasumi [1 ]
da Silva, Leonardo Folmer Rodrigues [1 ]
Roscoe, Marina Guimaraes [1 ]
Pinhata-Baptista, Otavio Henrique [3 ,4 ]
Meira, Josete Barbosa Cruz [1 ]
Fok, Alex Siu Lun [5 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Biomat & Oral Biol, Av Prof Lineu Prestes,2227, BR-05508000 Sao Paulo, Brazil
[2] Univ Cuiaba, Cuiaba, Brazil
[3] Univ Sao Paulo, Mil Hosp Sao Paulo Area, Dent Div, Sao Paulo, Brazil
[4] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, Brazil
[5] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Sch Dent, Minneapolis, MN USA
关键词
Mandible; Bone resorption; Dental implant; Dental prostheses; Occlusal load; ITI CONSENSUS REPORT; STRESS-DISTRIBUTION; SURROUNDING BONE; VALIDATION; DIAMETER; QUALITY; DESIGN; CROWNS; LENGTH;
D O I
10.2186/jpr.JPR_D_24_00003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate the risk of bone loss around single short molar crown-supporting implants in an atrophic mandible. Methods: Implants of different lengths (L = 4 or 6 mm) and diameters (0 = 4.1 or 4.8 mm) were placed in the molar area of an atrophic mandible. Additional control mandible models were simulated for 4.1 mm diameter implants (L = 4, 6, 8, and 10 mm). A vertical masticatory load of 200 N was applied to three or six occlusal contact areas (3ca or 6ca) of the prosthetic crown. The bone strain energy density (SED) of 109.6 mu J/mm3 was assumed to be the pathological threshold for cortical bone. The peri-implant bone resorption risk index (PIBRri) was calculated by dividing the maximum SED of the crestal cortical bone by the SED pathological threshold. Results: Increasing the implant length from 4 to 6 mm, implant diameter from 4.1 to 4.8 mm, and number of contact areas from 3 to 6 reduced the SED and PIBRri values by approximately 20%, 35%, and 40%, respectively, when comparing pairs of models that isolated a specific variable. All models with 6ca had a low bone resorption risk (PIBRri<0.8), while the 04.1 short implant with 3ca had a medium (0.8 <= PIBRri <= 1.0) or high (PIBRri>1.0) resorption risk. Conclusions: Increasing the diameter or occlusal contact area of a 4 mm short implant in an atrophic mandible resulted in reduced bone resorption risks, similar to or lower than those observed in a regular mandible with standard-length implants.
引用
收藏
页码:110 / 119
页数:10
相关论文
共 50 条
  • [21] Comparison of the rehabilitation of posterior atrophic edentulous mandible with different interforaminal implant placement concepts: a 3D finite element analysis
    Akca, B. S.
    Kucukkurt, S.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (03) : 155 - 164
  • [22] Radiographic Evaluation of Crestal Bone Loss Around Dental Implants in Maxilla and Mandible: One Year Prospective Clinical Study
    Ajanovic, Muhamed
    Hamzic, Adis
    Redzepagic, Sead
    Kamber-cesir, Alma
    Kazazic, Lejla
    Tosum, Selma
    ACTA STOMATOLOGICA CROATICA, 2015, 49 (02) : 128 - 136
  • [23] Rehabilitation atrophic mandible with short dental implants and titanium plate: A case report
    Alvarenga, Rodrigo Lopez
    Akaki, Emilio
    Rodrigues Antunes de Souza, Ana Cristina
    de Souza, Leandro Napier
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2013, 54 (04): : 217 - 221
  • [24] Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed in the atrophic posterior maxilla
    Chang, Shih-Hao
    Lin, Chun-Li
    Hsue, Shue-Sang
    Lin, Yang-Sung
    Huang, Shiang-Rung
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (02) : 153 - 160
  • [25] Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis
    Simsek, B
    Erkmen, E
    Yilmaz, D
    Eser, A
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (03) : 199 - 213
  • [26] Impact of annual bone loss and different bone quality on dental implant success - A finite element study
    Linetskiy, Igor
    Demenko, Vladyslav
    Linetska, Larysa
    Yefremov, Oleg
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 91 : 318 - 325
  • [27] Biomechanical evaluation of custom-made short implants with wing retention applied in severe atrophic maxillary posterior region restoration: A three-dimensional finite element analysis
    Yang, Zhen
    Zhang, Jingran
    Xu, Zexian
    Liu, Xiaoqiang
    Yang, Jianjun
    Tan, Jianguo
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [28] Peri-implant bone loss around posterior mandible dental implants placed after distraction osteogenesis: Preliminary findings
    Polo, Wilson C. K.
    de Araujo, Ney Soares
    Lima, Ynara B. O.
    Joly, Julio Cesar
    Sendyk, Wilson R.
    Cury, Patricia R.
    JOURNAL OF PERIODONTOLOGY, 2007, 78 (02) : 204 - 208
  • [29] Rehabilitation of Atrophic Posterior Maxilla with Pterygoid Implants: A 3D Finite Element Analysis
    Wilkirson, Elizabeth
    Chandran, Ravi
    Duan, Yuanyuan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : E51 - E62
  • [30] Influence of Crown-to-Implant Ratio on Long Term Marginal Bone Loss Around Short Implants
    Di Fiore, Adolfo
    Vigolo, Paolo
    Sivolella, Stefano
    Cavallin, Francesco
    Katsoulis, Joannis
    Monaco, Carlo
    Stellini, Edoardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 992 - 998