摘要
Background Data are lacking for the accuracy of computed tomography (CT) in measuring prostate size, which can streamline care and prevent invasive procedures. We evaluate agreement and intra/inter-observer variability in prostate sizing between CT and magnetic resonance imaging (MRI) planimetry for a wide range of gland sizes. Methods We retrospectively reviewed 700 patients who underwent MRI fusion biopsy at a single institution and identified 89 patients that had a CT within 2 years of the MRI. Six reviewers from different training levels were categorized as student, resident, or attending and each measured prostate size on CT by the prolate ellipse method. Bland-Altman analysis determined the degree of agreement between CT and MRI. Inter- and intra-observer reliability was calculated for CT. Results Mean CT volume was higher than MRI volume in the < 60 g group (51.5 g vs. 44.5 g, p = 0.004), but not in the >= 60 g group (101 g vs. 100 g, p = 0.458). The bias for overestimation of prostate volume by CT was 4.1 g across prostate volumes, but the proportional agreement between modalities improved with size. The Pearson correlation coefficient between CT/MRI and inter/intra-rater reliability for CT increased in the >= 60 g vs. the < 60 g group for all training levels. Conclusions Our data show that there is greater clinical utility for prostate size estimation by CT than previously established, particularly for larger glands where accurate size estimation may influence therapeutic decisions. In larger glands, prostate size estimation by CT is also reproducible across various training levels.
引用
收藏
页码:3241 / 3247
页数:7
相关论文
共 50 条
  • [21] Comparing Accuracy of Cerebral Aneurysm Size Measurements From Three Routine Investigations: Computed Tomography, Magnetic Resonance Imaging, and Digital Subtraction Angiography
    Takao, Hiroyuki
    Murayama, Yuichi
    Ishibashi, Toshihiro
    Saguchi, Takayuki
    Ebara, Masaki
    Arakawa, Hideki
    Irie, Koreaki
    Iwasaki, Kiyotaka
    Umezu, Mitsuo
    Abe, Toshiaki
    NEUROLOGIA MEDICO-CHIRURGICA, 2010, 50 (10) : 893 - 899
  • [22] The Role of Magnetic Resonance Imaging and Positron Emission Tomography/Computed Tomography in the Primary Staging of Newly Diagnosed Prostate Cancer: A Systematic Review of the Literature
    Abrams-Pompe, Raisa S.
    Fanti, Stefano
    Schoots, Ivo G.
    Moore, Caroline M.
    Turkbey, Baris
    Vickers, Andrew J.
    Walz, Jochen
    Steuber, Thomas
    Eastham, James A.
    EUROPEAN UROLOGY ONCOLOGY, 2021, 4 (03): : 370 - 395
  • [23] To evaluate volume changes on computerized tomography scan and magnetic resonance imaging-based delineation during radiotherapy treatment planning in prostate cancer
    Sarolkar, Anil
    Singh, Shashank N.
    Bagdare, Priyusha
    Bhandari, Virendra
    Lodi, Ashar Iqbal
    Moharir, Sarthak
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (02) : 379 - 382
  • [24] Quantification of right ventricular volume in dogs: a comparative study between three-dimensional echocardiography and computed tomography with the reference method magnetic resonance imaging
    Anne K Sieslack
    Peter Dziallas
    Ingo Nolte
    Patrick Wefstaedt
    Stephan O Hungerbühler
    BMC Veterinary Research, 10
  • [25] Quantification of right ventricular volume in dogs: a comparative study between three-dimensional echocardiography and computed tomography with the reference method magnetic resonance imaging
    Sieslack, Anne K.
    Dziallas, Peter
    Nolte, Ingo
    Wefstaedt, Patrick
    Hungerbuehler, Stephan O.
    BMC VETERINARY RESEARCH, 2014, 10
  • [26] AOSpine Global Survey: International Trends in Utilization of Magnetic Resonance Imaging/Computed Tomography for Spinal Trauma and Spinal Cord Injury across AO Regions
    Shabani, Saman
    Kaushal, Mayank
    Soliman, Hesham M.
    Nguyen, Ha Son
    Aarabi, Bizhan
    Fehlings, Michael G.
    Kotter, Mark
    Kwon, Brian K.
    Harrop, James
    Kurpad, Shekar N.
    JOURNAL OF NEUROTRAUMA, 2019, 36 (24) : 3323 - 3331
  • [27] Computed Tomography-Based Tumor Volume in Non-Hodgkin Lymphoma: Clinical Correlation and Comparison With Magnetic Resonance Imaging
    Rossi, Maija
    Pertovaara, Hannu
    Dastidar, Prasun
    Jarvenpaa, Ritva
    Luukkaala, Tiina
    Rautakunnas, Sylvia
    Heinonen, Tomi
    Eskola, Hannu
    Soimakallio, Seppo
    Kellokumpu-Lehtinen, Pirkko-Liisa
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (04) : 641 - 649
  • [28] Combined Utility of 68Ga-Prostate-specific Membrane Antigen Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging in Predicting Prostate Biopsy Pathology
    Kalapara, Arveen A.
    Ballok, Zita E.
    Ramdave, Shakher
    O'Sullivan, Richard
    Ryan, Andrew
    Konety, Badrinath
    Grummet, Jeremy P.
    Frydenberg, Mark
    EUROPEAN UROLOGY ONCOLOGY, 2022, 5 (03): : 314 - 320
  • [29] Voxel-wise correlation of positron emission tomography/computed tomography with multiparametric magnetic resonance imaging and histology of the prostate using a sophisticated registration framework
    Reynolds, Hayley M.
    Williams, Scott
    Jackson, Price
    Mitchell, Catherine
    Hofman, Michael S.
    Hicks, Rodney J.
    Murphy, Declan G.
    Haworth, Annette
    BJU INTERNATIONAL, 2019, 123 (06) : 1020 - 1030
  • [30] Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration
    Parker, CC
    Damyanovich, A
    Haycocks, T
    Haider, M
    Bayley, A
    Catton, CN
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (02) : 217 - 224