Feasibility of determining external beam radiotherapy dose using LuSy dosimeter

被引:0
作者
Wahabi, Janatul Madinah [1 ,2 ]
Wong, Jeannie Hsiu Ding [1 ,3 ]
Mahdiraji, Ghafour A. [4 ]
Ung, Ngie Min [5 ]
机构
[1] Univ Malaya, Fac Med, Dept Biomed Imaging, Kuala Lumpur 50603, Malaysia
[2] Natl Canc Inst, Radiotherapy & Oncol Dept, Putrajaya, Malaysia
[3] Univ Malaya, Univ Malaya Res Imaging Ctr UMRIC, Fac Med, Kuala Lumpur, Malaysia
[4] Univ Malaya, Flexilicate Sdn Bhd, Kuala Lumpur, Malaysia
[5] Univ Malaya, Fac Med, Clin Oncol Unit, Kuala Lumpur, Malaysia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 06期
关键词
conformal radiotherapy; IMRT; plastic scintillator; SRS; VMAT; PLASTIC SCINTILLATION DETECTORS; ACCURACY; ELECTRON;
D O I
10.1002/acm2.14387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
IntroductionRadiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS).Materials and methodsA new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS).ResultsFor CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively.ConclusionThe LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.
引用
收藏
页数:10
相关论文
共 35 条
[1]   Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams [J].
Alsanea, Fahed ;
Darne, Chinmay ;
Robertson, Daniel ;
Beddar, Sam .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (07)
[2]  
[Anonymous], 2017, Dosimetry of Small Static Fields Used in Radiotherapy: An International Code of Practice for Reference and Relative Dose Determination Technical Report Series 484
[3]  
[Anonymous], 2004, COMMISSIONING QUALIT
[4]   A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors [J].
Archambault, Louis ;
Therriault-Proulx, Francois ;
Beddar, Sam ;
Beaulieu, Luc .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21) :7133-7145
[5]   Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy [J].
Beaulieu, Luc ;
Beddar, Sam .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20) :R305-R343
[6]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[7]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[8]   A SiPM based real time dosimeter for radiotherapic beams [J].
Berra, A. ;
Conti, V. ;
Lietti, D. ;
Milan, L. ;
Novati, C. ;
Ostinelli, A. ;
Prest, M. ;
Romano, C. ;
Vallazza, E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 773 :72-80
[9]   Dosimetric characterization of a small-scale (Zn,Cd)S:Ag inorganic scintillating detector to be used in radiotherapy [J].
Debnath, Sree Bash Chandra ;
Tonneau, Didier ;
Fauquet, Carole ;
Tallet, Agnes ;
Goncalves, Anthony ;
Darreon, Julien .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 :15-23
[10]   Spectral discrimination of Cerenkov radiation in scintillating dosimeters [J].
Frelin, AM ;
Fontbonne, JM ;
Ban, G ;
Colin, J ;
Labalme, M ;
Batalla, A ;
Isambert, A ;
Vela, A ;
Leroux, T .
MEDICAL PHYSICS, 2005, 32 (09) :3000-3006