A User-Configurable Smartwatch as a Point-of-Care Testing Device for Electrochemical Biosensors

被引:1
|
作者
Raj, S. Vineeth [1 ]
Pradeep, Aarathi [2 ]
Raveendran, Jeethu [3 ,4 ]
Nair, Bipin G. [5 ]
Babu, T. G. Satheesh [2 ]
Suneesh, P. V. [2 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Elect & Commun Engn, Coimbatore 641112, India
[2] Amrita Vishwa Vidyapeetham, Amrita Sch Phys Sci, Dept Sci, Amrita Biosensor Res Lab, Coimbatore 641112, India
[3] Amrita Vishwa Vidyapeetham, Amrita Biosensor Res Lab, Coimbatore 641112, India
[4] Sahrudaya Coll Engn & Technol, Dept Biomed Engn, Trichur 680684, Kerala, India
[5] Amrita Vishwa Vidyapeetham, Amrita Sch Biotechnol, Kollam 690525, Kerala, India
关键词
Sensors; Wearable Health Monitoring Systems; Testing; Electrodes; Electric potential; Biomarkers; Biosensors; Amperometry; point-of-care testing (PoCT); smartwatch; voltammetry; wearable device; FABRICATION; DIAGNOSIS;
D O I
10.1109/JSEN.2024.3397869
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The article presents the development of a wristwatch as a configurable testing platform for personalized point-of-care testing (PoCT). The developed watch can perform voltammetry and amperometry in a wide operating range, thus making the system capable of detecting various bioanalytes. This overcomes a major limitation of the existing meters available in the market, where each sensor requires a dedicated meter. The user selects the desired biomolecule for quantification on the smartphone using the developed Android mobile application. The test parameters are transferred via Bluetooth, and the smartwatch is tuned to the chosen sensor. As a proof-of-concept, we have developed electrochemical biosensors for testing clinically significant biomolecules such as glucose, uric acid (UA), and ascorbic acid (AA), which was then interfaced with the smartwatch for the on-demand quantification. Using an analog-to-digital converter (ADC) with 12-bit resolution, the device demonstrated a high resolution of 0.732 mV. The smartwatch could overcome the limitation associated with the quantification of UA in the presence of AA by doing baseline subtraction, and the results show a low relative standard deviation of 4%. The glucose analysis was highly reproducible with a relative standard deviation of 4.95%, with a high resolution of 0.0217 mg dL(-1), and the results could be obtained within 5 s. The results obtained using the smartwatch were in excellent conformity with those obtained from a laboratory electrochemical workstation. The key advantage of the device is that it can be easily configured to test any new biomarkers without any hardware change by over-the-air mobile application updates.
引用
收藏
页码:20805 / 20812
页数:8
相关论文
共 50 条
  • [1] Electrochemical biosensors for point-of-care testing
    Jinsol Kim
    Juho Jeong
    Seung Hwan Ko
    Bio-DesignandManufacturing, 2024, 7 (04) : 548 - 565
  • [2] Electrochemical biosensors for point-of-care testing
    Kim, Jinsol
    Jeong, Juho
    Ko, Seung Hwan
    BIO-DESIGN AND MANUFACTURING, 2024, 7 (04) : 548 - 565
  • [3] Electrochemical Biosensors for Point-of-care Applications
    Karunakaran, Chandran
    Karthikeyan, Murugesan
    Kumar, Marimuthu Dhinesh
    Kaniraja, Ganesan
    Bhargava, Kalpana
    DEFENCE SCIENCE JOURNAL, 2020, 70 (05) : 549 - 556
  • [4] Electrochemical biosensors for point-of-care applications
    Karunakaran C.
    Karthikeyan M.
    Kumar M.D.
    Kaniraja G.
    Bhargava K.
    Def. Sci. J., 2020, 5 (549-556): : 549 - 556
  • [5] Paper-Based Electrochemical Biosensors for Point-of-Care Testing of Neurotransmitters
    Yingchun Li
    Rongyan He
    Yan Niu
    Fei Li
    Journal of Analysis and Testing, 2019, 3 : 19 - 36
  • [6] Paper-Based Electrochemical Biosensors for Point-of-Care Testing of Neurotransmitters
    Li, Yingchun
    He, Rongyan
    Niu, Yan
    Li, Fei
    JOURNAL OF ANALYSIS AND TESTING, 2019, 3 (01) : 19 - 36
  • [7] Pebbles: User-Configurable Device Network for Robot Navigation
    Ishii, Kentaro
    Mi, Haipeng
    Ma, Lei
    Laokulrat, Natsuda
    Inami, Masahiko
    Igarashi, Takeo
    HUMAN-COMPUTER INTERACTION - INTERACT 2013, PT II, 2013, 8118 : 420 - 436
  • [8] On the testing of user-configurable software systems using firewalls
    Robinson, Brian
    White, Lee
    SOFTWARE TESTING VERIFICATION & RELIABILITY, 2012, 22 (01): : 3 - 31
  • [9] Biosensors technologies for point-of-care testing - a review
    Baluta S.
    Cabaj J.
    Malecha K.
    Periodica polytechnica Electrical engineering and computer science, 2020, 64 (04): : 325 - 333
  • [10] Trends in miniaturized biosensors for point-of-care testing
    Liu, Dan
    Wang, Junxia
    Wu, Lingling
    Huang, Yishun
    Zhang, Yuqian
    Zhu, Mingyang
    Wang, Yang
    Zhu, Zhi
    Yang, Chaoyong
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 122 (122)