Evaluation of the Transfemoral Bone-Implant Interface Properties Using Vibration Analysis

被引:1
|
作者
Mohamed, Mostafa [1 ]
Beaudry, Eric [1 ]
Shehata, Ahmed W. [1 ,2 ,3 ]
Raboud, Donald [1 ]
Hebert, Jacqueline S. [2 ,3 ,4 ]
Westover, Lindsey [1 ,2 ,3 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Alberta, Fac Med, Dept Biomed Engn, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[4] Univ Alberta, Fac Med & Dent, Dept Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Advanced system for implant stability testing; Bone-anchored implants; Transfemoral amputation; Vibration analysis; FREQUENCY-ANALYSIS; OSSEOINTEGRATION; STABILITY; RECONSTRUCTION; REHABILITATION; AMPUTEES; SYSTEM;
D O I
10.1007/s10439-024-03561-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluating the bone-implant interface (BII) properties of osseointegrated transfemoral (TFA) implants is important for early failure detection and prescribing loads during rehabilitation. The objective of this work is to derive and validate a 1D finite element (FE) model of the Osseointegrated Prosthetic Limb (OPL) TFA system that can: (1) model its dynamic behaviour and (2) extract the BII properties. The model was validated by: (1) comparing the 1D FE formulation to the analytical and 3D FE solutions for a simplified cylinder, (2) comparing the vibration modes of the actual TFA geometry using 1D and 3D FE models, and (3) evaluating the BII properties for three extreme conditions (LOW, INTERMEDIATE, and HIGH) generated using 3D FE and experimental (where the implant was embedded, using different adhesives, in synthetic femurs) signals for additional validation. The modes predicted by the 1D FE model converged to the analytical and the 3D FE solutions for the cylinder. The 1D model also matched the 3D FE solution with a maximum frequency difference of 2.02% for the TFA geometry. Finally, the 1D model extracted the BII stiffness and the system's damping properties for the three conditions generated using the 3D FE simulations and the experimental INTERMEDIATE and HIGH signals. The agreement between the 1D FE and the 3D FE solutions for the TFA geometry indicates that the 1D model captures the system's dynamic behaviour. Distinguishing between the different BII conditions demonstrates the 1D model's potential use for the non-invasive clinical evaluation of the TFA BII properties.
引用
收藏
页码:2987 / 3008
页数:22
相关论文
共 50 条
  • [31] An FE model investigating the bone-implant interface of Osseointegrated prosthetics to better understand how forces are transferred under loading
    Mcguire, Tiereny
    Ramasamy, Arul
    Bull, Anthony M. J.
    MEDICAL ENGINEERING & PHYSICS, 2025, 137
  • [32] Evaluation of bone-implant integration: Efficiency and precision of 3 methods
    McMillan, PJ
    Kim, J
    Garrett, S
    Crigger, M
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1999, 14 (05) : 631 - 638
  • [33] Characterization of bone-implant fixation using modal analysis: Application to a press-fit implant model
    Swider, P.
    Guerin, G.
    Baas, Joergen
    Soballe, Kjeld
    Bechtold, Joan E.
    JOURNAL OF BIOMECHANICS, 2009, 42 (11) : 1643 - 1649
  • [34] Strain of bone-implant interface and insertion torque regarding different miniscrew thread designs using an artificial bone model
    Cha, Jung-Yul
    Hwang, Chung-Ju
    Kwon, Sung Hwang
    Jung, Han-Sung
    Kim, Kwang-Mahn
    Yu, Hyung Seog
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (03) : 268 - 274
  • [35] The Influence of Bone Type on the Gene Expression in Normal Bone and at the Bone-Implant Interface: Experiments in Animal Model
    Omar, Omar
    Suska, Felicia
    Lenneras, Maria
    Zoric, Neven
    Svensson, Sara
    Hall, Jan
    Emanuelsson, Lena
    Nannmark, Ulf
    Thomsen, Peter
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (02) : 146 - 156
  • [36] Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface
    Walsh, William R.
    Bertollo, Nicky
    Christou, Chrisopher
    Schaffner, Dominik
    Mobbs, Ralph J.
    SPINE JOURNAL, 2015, 15 (05): : 1041 - 1049
  • [37] Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation
    Dhatrak, Pankaj
    Girme, Vedant
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    BIONANOSCIENCE, 2019, 9 (03) : 652 - 659
  • [38] Numerical analysis of an osteoconduction model arising in bone-implant integration
    Fernandez, Jose R.
    Manuel Garcia-Aznar, Jose
    Masid, Maria
    ZAMM-ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 2017, 97 (09): : 1050 - 1063
  • [39] Osseointegration improves bone-implant interface of pedicle screws in the growing spine: a biomechanical and histological study using an in vivo immature porcine model
    Shiba, Kanako
    Taneichi, Hiroshi
    Namikawa, Takashi
    Inami, Satoshi
    Takeuchi, Daisaku
    Nohara, Yutaka
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2754 - 2762
  • [40] A novel micromotion measurement method to gain instructive insight into the acetabular bone-implant interface
    Heilemann, Martin
    Wendler, Toni
    Muenst, Philipp
    Schleifenbaum, Stefan
    Scholz, Roger
    Voigt, Christian
    MEDICAL ENGINEERING & PHYSICS, 2020, 86 : 138 - 145