Evaluation of the Transfemoral Bone-Implant Interface Properties Using Vibration Analysis

被引:1
|
作者
Mohamed, Mostafa [1 ]
Beaudry, Eric [1 ]
Shehata, Ahmed W. [1 ,2 ,3 ]
Raboud, Donald [1 ]
Hebert, Jacqueline S. [2 ,3 ,4 ]
Westover, Lindsey [1 ,2 ,3 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Alberta, Fac Med, Dept Biomed Engn, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[4] Univ Alberta, Fac Med & Dent, Dept Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Advanced system for implant stability testing; Bone-anchored implants; Transfemoral amputation; Vibration analysis; FREQUENCY-ANALYSIS; OSSEOINTEGRATION; STABILITY; RECONSTRUCTION; REHABILITATION; AMPUTEES; SYSTEM;
D O I
10.1007/s10439-024-03561-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluating the bone-implant interface (BII) properties of osseointegrated transfemoral (TFA) implants is important for early failure detection and prescribing loads during rehabilitation. The objective of this work is to derive and validate a 1D finite element (FE) model of the Osseointegrated Prosthetic Limb (OPL) TFA system that can: (1) model its dynamic behaviour and (2) extract the BII properties. The model was validated by: (1) comparing the 1D FE formulation to the analytical and 3D FE solutions for a simplified cylinder, (2) comparing the vibration modes of the actual TFA geometry using 1D and 3D FE models, and (3) evaluating the BII properties for three extreme conditions (LOW, INTERMEDIATE, and HIGH) generated using 3D FE and experimental (where the implant was embedded, using different adhesives, in synthetic femurs) signals for additional validation. The modes predicted by the 1D FE model converged to the analytical and the 3D FE solutions for the cylinder. The 1D model also matched the 3D FE solution with a maximum frequency difference of 2.02% for the TFA geometry. Finally, the 1D model extracted the BII stiffness and the system's damping properties for the three conditions generated using the 3D FE simulations and the experimental INTERMEDIATE and HIGH signals. The agreement between the 1D FE and the 3D FE solutions for the TFA geometry indicates that the 1D model captures the system's dynamic behaviour. Distinguishing between the different BII conditions demonstrates the 1D model's potential use for the non-invasive clinical evaluation of the TFA BII properties.
引用
收藏
页码:2987 / 3008
页数:22
相关论文
共 50 条
  • [21] The bone-implant interface of dental implants in humans on the atomic scale
    Sundell, Gustav
    Dahlin, Christer
    Andersson, Martin
    Thuvander, Mattias
    ACTA BIOMATERIALIA, 2017, 48 : 445 - 450
  • [22] Spatio-temporal evolution of hydroxyapatite crystal thickness at the bone-implant interface
    Le Cann, Sophie
    Tornquist, Elin
    Barreto, Isabella Silva
    Fraulob, Manon
    Lomami, Hugues Albini
    Verezhak, Mariana
    Guizar-Sicairos, Manuel
    Isaksson, Hanna
    Haiat, Guillaume
    ACTA BIOMATERIALIA, 2020, 116 : 391 - 399
  • [23] Micromechanical modeling of the contact stiffness of an osseointegrated bone-implant interface
    Raffa, Maria Letizia
    Vu-Hieu Nguyen
    Haiat, Guillaume
    BIOMEDICAL ENGINEERING ONLINE, 2019, 18 (01)
  • [24] Ultrasonic assessment of osseointegration phenomena at the bone-implant interface using convolutional neural network
    Kwak, Yunsang
    Nguyen, Vu-Hieu
    Heriveaux, Yoann
    Belanger, Pierre
    Park, Junhong
    Haiat, Guillaume
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 149 (06): : 4337 - 4347
  • [25] Mechanical properties of bone-implant interface: An in vitro model for the comparison of stability parameters affecting various stages during osseointegration for dental implant
    Pan, RLC
    Ying, SH
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 5050 - 5052
  • [26] Dental implant stability and its measurements to improve osseointegration at the bone-implant interface: A review
    Kittur, Nidhi
    Oak, Radhika
    Dekate, Deepali
    Jadhav, Saakshi
    Dhatrak, Pankaj
    MATERIALS TODAY-PROCEEDINGS, 2021, 43 : 1064 - 1070
  • [27] Analytical modeling of the interaction of an ultrasonic wave with a rough bone-implant interface
    Heriveaux, Yoann
    Vu-Hieu Nguyen
    Biwa, Shiro
    Haiat, Guillaume
    ULTRASONICS, 2020, 108
  • [28] PUTATIVE EARLY RISK FACTORS AT BONE-IMPLANT INTERFACE IN IMMEDIATE LOADING
    Iliescu, Alexandru-Andrei
    Iliescu, Radita
    Rusu, Darian
    Didilescu, Andreea Cristiana
    Tanase, Gabriela
    Iliescu, Andrei
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2009, 1 (01): : 25 - 33
  • [29] Reflection of an ultrasonic wave on the bone-implant interface: Effect of the roughness parameters
    Heriveaux, Yoann
    Vu-Hieu Nguyen
    Brailovski, Vladimir
    Gorny, Cyril
    Haiat, Guillaume
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2019, 145 (06): : 3370 - 3381
  • [30] Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation
    Chen, Hsiang-Ho
    Lai, Wei-Yi
    Chee, Tze-Jian
    Chan, Ya-Hui
    Feng, Sheng-Wei
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017