Evaluation of the Transfemoral Bone-Implant Interface Properties Using Vibration Analysis

被引:1
|
作者
Mohamed, Mostafa [1 ]
Beaudry, Eric [1 ]
Shehata, Ahmed W. [1 ,2 ,3 ]
Raboud, Donald [1 ]
Hebert, Jacqueline S. [2 ,3 ,4 ]
Westover, Lindsey [1 ,2 ,3 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Alberta, Fac Med, Dept Biomed Engn, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[4] Univ Alberta, Fac Med & Dent, Dept Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Advanced system for implant stability testing; Bone-anchored implants; Transfemoral amputation; Vibration analysis; FREQUENCY-ANALYSIS; OSSEOINTEGRATION; STABILITY; RECONSTRUCTION; REHABILITATION; AMPUTEES; SYSTEM;
D O I
10.1007/s10439-024-03561-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluating the bone-implant interface (BII) properties of osseointegrated transfemoral (TFA) implants is important for early failure detection and prescribing loads during rehabilitation. The objective of this work is to derive and validate a 1D finite element (FE) model of the Osseointegrated Prosthetic Limb (OPL) TFA system that can: (1) model its dynamic behaviour and (2) extract the BII properties. The model was validated by: (1) comparing the 1D FE formulation to the analytical and 3D FE solutions for a simplified cylinder, (2) comparing the vibration modes of the actual TFA geometry using 1D and 3D FE models, and (3) evaluating the BII properties for three extreme conditions (LOW, INTERMEDIATE, and HIGH) generated using 3D FE and experimental (where the implant was embedded, using different adhesives, in synthetic femurs) signals for additional validation. The modes predicted by the 1D FE model converged to the analytical and the 3D FE solutions for the cylinder. The 1D model also matched the 3D FE solution with a maximum frequency difference of 2.02% for the TFA geometry. Finally, the 1D model extracted the BII stiffness and the system's damping properties for the three conditions generated using the 3D FE simulations and the experimental INTERMEDIATE and HIGH signals. The agreement between the 1D FE and the 3D FE solutions for the TFA geometry indicates that the 1D model captures the system's dynamic behaviour. Distinguishing between the different BII conditions demonstrates the 1D model's potential use for the non-invasive clinical evaluation of the TFA BII properties.
引用
收藏
页码:2987 / 3008
页数:22
相关论文
共 50 条
  • [1] Stress shielding at the bone-implant interface: Influence of surface roughness and of the bone-implant contact ratio
    Raffa, Maria Letizia
    Nguyen, Vu-Hieu
    Hernigou, Philippe
    Flouzat-Lachaniette, Charles-Henri
    Haiat, Guillaume
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (06) : 1174 - 1183
  • [2] Proteoglycans at the bone-implant interface
    Klinger, MM
    Rahemtulla, F
    Prince, CW
    Lucas, LC
    Lemons, JE
    CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 1998, 9 (04) : 449 - 463
  • [3] Efficacy of Resonance Frequency Analysis in the Diagnosis of Compromised Bone-Implant Interface
    Cavusoglu, Yeliz
    Sahin, Erdal
    Akca, Kivanc
    IMPLANT DENTISTRY, 2012, 21 (05) : 394 - 398
  • [4] The bone-implant interface: A dynamic surface
    Goldberg, VM
    Jinno, T
    JOURNAL OF LONG-TERM EFFECTS OF MEDICAL IMPLANTS, 1999, 9 (1-2) : 11 - 21
  • [5] Biomechanical determinants of the stability of dental implants: Influence of the bone-implant interface properties
    Mathieu, Vincent
    Vayron, Romain
    Richard, Gilles
    Lambert, Gregory
    Naili, Salah
    Meningaud, Jean-Paul
    Haiat, Guillaume
    JOURNAL OF BIOMECHANICS, 2014, 47 (01) : 3 - 13
  • [6] Multiscale Analyses of the Bone-implant Interface
    Cha, J. Y.
    Pereira, M. D.
    Smith, A. A.
    Houschyar, K. S.
    Yin, X.
    Mouraret, S.
    Brunski, J. B.
    Helms, J. A.
    JOURNAL OF DENTAL RESEARCH, 2015, 94 (03) : 482 - 490
  • [7] In vitro assessment of bone-implant interface using an acoustic emission transmission test
    Ossi, Zannar
    Abdou, Wael
    Reuben, Robert L.
    Ibbetson, Richard J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H1) : 63 - 69
  • [8] Neutron microtomography to investigate the bone-implant interface-comparison with histological analysis
    Guillaume, Florian
    Le Cann, Sophie
    Tengattini, Alessandro
    Tornquist, Elin
    Falentin-Daudre, Celine
    Albini Lomami, Hugues
    Petit, Yvan
    Isaksson, Hanna
    Haiat, Guillaume
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (10):
  • [9] Osseointegration and current interpretations of the bone-implant interface
    Shah, Furqan A.
    Thomsen, Peter
    Palmquist, Anders
    ACTA BIOMATERIALIA, 2019, 84 : 1 - 15
  • [10] Biomechanical behaviours of the bone-implant interface: a review
    Gao, Xing
    Fraulob, Manon
    Haiat, Guillaume
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2019, 16 (156)