Pillar data-acquisition strategies for cryo-electron tomography of beam-sensitive biological samples

被引:1
作者
Parkhurst, James M. [1 ,2 ]
Varslot, Trond [3 ]
Dumoux, Maud [1 ]
Siebert, C. Alistair [2 ]
Darrow, Michele [1 ]
Basham, Mark [1 ]
Kirkland, Angus [1 ,4 ,5 ]
Grange, Michael [1 ]
Evans, Gwyndaf [1 ,2 ]
Naismith, James H. [1 ,6 ]
机构
[1] Rosalind Franklin Inst, Harwell Sci & Innovat Campus, Didcot OX11 0FA, Oxon, England
[2] Diamond Light Source, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[3] Thermo Fisher Sci, Brno, Czech Republic
[4] Diamond Light Source, Electron Phys Sci Imaging Ctr, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[5] Univ Oxford, Dept Mat, Parks Rd, Oxford OX1 3PH, England
[6] Univ Oxford, Div Struct Biol, Roosevelt Dr, Oxford OX3 7BN, England
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2024年 / 80卷
基金
英国惠康基金;
关键词
cryo-electron tomography; cryo-ET; multislice image simulation; data-collection strategy; reconstruction; alignment; beam sensitive specimens; SCATTERING; FIB; RECONSTRUCTION; FABRICATION; ELECTRONS; SPECIMENS; ACCURATE; ATOMS;
D O I
10.1107/S2059798324004546
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For cryo-electron tomography (cryo-ET) of beam-sensitive biological specimens, a planar sample geometry is typically used. As the sample is tilted, the effective thickness of the sample along the direction of the electron beam increases and the signal-to-noise ratio concomitantly decreases, limiting the transfer of information at high tilt angles. In addition, the tilt range where data can be collected is limited by a combination of various sample-environment constraints, including the limited space in the objective lens pole piece and the possible use of fixed conductive braids to cool the specimen. Consequently, most tilt series are limited to a maximum of +/- 70 degrees, leading to the presence of a missing wedge in Fourier space. The acquisition of cryo-ET data without a missing wedge, for example using a cylindrical sample geometry, is hence attractive for volumetric analysis of low-symmetry structures such as organelles or vesicles, lysis events, pore formation or filaments for which the missing information cannot be compensated by averaging techniques. Irrespective of the geometry, electron-beam damage to the specimen is an issue and the first images acquired will transfer more high-resolution information than those acquired last. There is also an inherent trade-off between higher sampling in Fourier space and avoiding beam damage to the sample. Finally, the necessity of using a sufficient electron fluence to align the tilt images means that this fluence needs to be fractionated across a small number of images; therefore, the order of data acquisition is also a factor to consider. Here, an n-helix tilt scheme is described and simulated which uses overlapping and interleaved tilt series to maximize the use of a pillar geometry, allowing the entire pillar volume to be reconstructed as a single unit. Three related tilt schemes are also evaluated that extend the continuous and classic dose-symmetric tilt schemes for cryo-ET to pillar samples to enable the collection of isotropic information across all spatial frequencies. A fourfold dose-symmetric scheme is proposed which provides a practical compromise between uniform information transfer and complexity of data acquisition.
引用
收藏
页码:421 / 438
页数:18
相关论文
共 42 条
[1]   A Workflow for Protein Structure Determination From Thin Crystal Lamella by Micro-Electron Diffraction [J].
Beale, Emma, V ;
Waterman, David G. ;
Hecksel, Corey ;
van Rooyen, Jason ;
Gilchrist, James B. ;
Parkhurst, James M. ;
de Haas, Felix ;
Buijsse, Bart ;
Evans, Gwyndaf ;
Zhang, Peijun .
FRONTIERS IN MOLECULAR BIOSCIENCES, 2020, 7
[2]   A convolutional neural network for fast upsampling of undersampled tomograms in X-ray CT time-series using a representative highly sampled tomogram [J].
Bellos, Dimitrios ;
Basham, Mark ;
Pridmore, Tony ;
French, Andrew P. .
JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 :839-853
[3]  
Berger C., 2022, Nat. Commun., V14, P629
[4]  
Chua E. Y. D., 2023, bioRxiv
[5]   THE SCATTERING OF ELECTRONS BY ATOMS AND CRYSTALS .1. A NEW THEORETICAL APPROACH [J].
COWLEY, JM ;
MOODIE, AF .
ACTA CRYSTALLOGRAPHICA, 1957, 10 (10) :609-619
[6]   Parallel cryo electron tomography on in situ lamellae [J].
Eisenstein, Fabian ;
Yanagisawa, Haruaki ;
Kashihara, Hiroka ;
Kikkawa, Masahide ;
Tsukita, Sachiko ;
Danev, Radostin .
NATURE METHODS, 2023, 20 (01) :131-+
[7]  
Frank J., 2005, Electron Tomography: Methods for Three-Dimensional Visualization of Structures in the Cell, VSecond
[8]   A new FIB fabrication method for micropillar specimens for three-dimensional observation using scanning transmission electron microscopy [J].
Fukuda, M ;
Tomimatsu, S ;
Nakamura, K ;
Koguchi, M ;
Shichi, H ;
Umemura, K .
JOURNAL OF ELECTRON MICROSCOPY, 2004, 53 (05) :479-483
[9]   NUMERICAL EVALUATION OF N-BEAM WAVE-FUNCTIONS IN ELECTRON-SCATTERING BY MULTI-SLICE METHOD [J].
GOODMAN, P ;
MOODIE, AF .
ACTA CRYSTALLOGRAPHICA SECTION A, 1974, A 30 (MAR) :280-290
[10]  
Grandi G., 1728, Flores geometrici ex Rhodonearum, et Cloeliarum curvarum descriptione resultantes