Comparison of Scheimpflug Corneal Tomography and Anterior Segment Optical Coherence Tomography Measurements in Corneal Cystinosis: A Case Series

被引:1
|
作者
Vercauteren, Leonie [1 ,2 ]
Consejo, Alejandra [3 ]
De Vries, Meindert Jan [1 ,2 ]
Krolo, Iva [1 ,4 ,5 ]
Koppen, Carina [1 ,2 ]
Dhubhghaill, Sorcha Ni [1 ,2 ,4 ,5 ]
机构
[1] Antwerp Univ Hosp, Dept Ophthalmol, Edegem, Belgium
[2] Univ Antwerp, Dept Hlth Sci, Antwerp, Belgium
[3] Univ Zaragoza, Aagon Inst Engn Res I3A, Zaragoza, Spain
[4] Univ Hosp Brussels, Dept Ophthalmol, Jette, Belgium
[5] Univ Brussels, Dept Ophthalmol, Brussels Hlth Campus,Laarbeeklaan 103, B-1090 Brussels, Belgium
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2024年 / 50卷 / 07期
关键词
Cystinosis; Central corneal thickness; Scheimpflug tomography; Anterior segment optical coherence tomography; Corneal densitometry; VIVO CONFOCAL MICROSCOPY; CYSTEAMINE EYE DROPS; NEPHROPATHIC CYSTINOSIS; DENSITOMETRY; AGE;
D O I
10.1097/ICL.0000000000001087
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To report the clinical course and compare the utility of Scheimpflug tomography (ST) and anterior segment optical coherence tomography (AS-OCT) for central corneal thickness (CCT) and corneal densitometry (CD) assessment in patients with corneal crystals owing to nephropathic cystinosis.Methods:A retrospective chart analysis of three patients with nephropathic cystinosis and the presence of corneal cystine crystals in both eyes was performed. All patients underwent clinical examination and anterior segment photography, ST, and AS-OCT scans. Corneal densitometry was exported from built-in proprietary software for ST and from custom-made validated software for AS-OCT. Anterior segment optical coherence tomography images were rescaled to grayscale units from 0 (maximum transparency) to 100 (minimum transparency) to match built-in ST densitometry readings. Furthermore, the mean pixel intensity, representative of CD, was calculated from the pixels corresponding to the segmented cornea.Results:All three patients had pathognomonic cystine crystals deposits in the cornea and were treated with cysteamine medications that resulted in clinical improvement. The CCT measured using ST exhibited a range from 560 to 958 mu m. Conversely, when assessed with AS-OCT, the CCT varied within the range of 548 to 610 mu m. Both examinations could be performed, but in the more severe cases, AS-OCT showed far greater utility to estimate CD. In four of six eyes examined, ST showed disproportionate CCT values, compared with the AS-OCT, whereas reliable CD measurements were only available in AS-OCT.Conclusion:The AS-OCT could be considered a baseline ocular measurement in cystinosis and in the evaluation of disease progression and treatment efficacy.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 50 条
  • [1] Comparison of central corneal thickness measurements in corneal edema using ultrasound pachymetry, Visante anterior-segment optical coherence tomography, Cirrus optical coherence tomography, and Pentacam Scheimpflug camera tomography
    Wongchaisuwat, Nida
    Metheetrairat, Ankana
    Chonpimai, Pratuangsri
    Nujoi, Waree
    Prabhasawat, Pinnita
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1865 - 1873
  • [2] Evaluation of Corneal Opacities in Patients with Cystinosis by using Anterior Segment Optical Coherence Tomography
    Yamamoto, Yuuka
    Okamura, Tadashi
    Shimizu, Yukiko
    Akahira, Moe
    Ookuma, Yoshiaki
    Itinohe, Shou
    Hukushima, Harumi
    Ueta, Takashi
    Yashiro, Shigeko
    Nagahara, Miyuki
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [3] Anterior Segment Optical Coherence Tomography in Corneal Ulcers
    Sitnik, H.
    Imshenetskaya, T.
    8TH INTERNATIONAL SYMPOSIUM ON OCULAR PHARMACOLOGY AND THERAPEUTICS - ISOPT, 2009, : 181 - 186
  • [4] Comparison of anterior segment optical coherence tomography angiography systems for corneal vascularisation
    Ang, Marcus
    Devarajan, Kavya
    Das, Suchandrima
    Stanzel, Tisha
    Tan, Anna
    Girard, Michael
    Schmetterer, Leopold
    Mehta, Jodhbir S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (07) : 873 - 877
  • [5] Corneal graphite deposit on anterior segment optical coherence tomography
    Vijitha, V. S.
    Kapoor, Anasua Ganguly
    Mohammed, Mansoor
    Roy, Aravind
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (07) : 1178 - 1178
  • [6] Anterior Segment Optical Coherence Tomography in Congenital Corneal Opacities
    Majander, Anna S.
    Lindahl, Paivi M.
    Vasara, L. Kristiina
    Krootila, Kari
    OPHTHALMOLOGY, 2012, 119 (12) : 2450 - 2457
  • [7] Comparison of a New Swept-Source Anterior Segment Optical Coherence Tomography and a Scheimpflug Camera for Measurement of Corneal Curvature
    Zhang, Ting
    Zhou, Yijing
    Young, Charlotte Aimee
    Chen, Aiming
    Jin, Guangming
    Zheng, Danying
    CORNEA, 2020, 39 (07) : 818 - 822
  • [8] Comparison of Corneal Thickness Measurements After Customized Corneal Crosslinking Using High-Resolution Optical Coherence Tomography and Scheimpflug Tomography
    Baiao, Tiago Mendes
    Wendelstein, Jascha
    Seiler, Theo G.
    CORNEA, 2023, 42 (09) : 1104 - 1109
  • [9] Comparison of central corneal thickness measurements by visante anterior segment optical coherence tomography with ultrasound pachymetry
    Zhao, Paul S.
    Wong, Tien Yin
    Wong, Wan-Ling
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 143 (06) : 1047 - 1049
  • [10] Repeatability of corneal and epithelial thickness measurements with anterior segment optical coherence tomography in keratoconus
    Li, Ye
    Gokul, Akilesh
    McGhee, Charles
    Ziaei, Mo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 884 - 885