A visual defrosting control method for air source heat pump system based on machine vision

被引:4
|
作者
Zhao, Han [1 ]
Liu, Zihan [1 ]
Sang, Yufeng [1 ]
Chang, Junzhi [2 ]
Zheng, Xuejing [1 ]
Jurasz, Jakub [3 ]
Zheng, Wandong [1 ,4 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] North China Municipal Engn Design & Res Inst Co Lt, Tianjin 300074, Peoples R China
[3] Wroclaw Univ Sci & Technol, Fac Environm Engn, PL-50370 Wroclaw, Poland
[4] Tianjin Univ, Key Lab Efficient Utilizat Low & Medium Grade Ener, Minist Educ China, Tianjin 300350, Peoples R China
关键词
Machine vision; Defrosting control method; Fractal dimension; Image processing technology; Air source heat pump; FROST FORMATION; PERFORMANCE; EXCHANGER; UNIT;
D O I
10.1016/j.energy.2024.131778
中图分类号
O414.1 [热力学];
学科分类号
摘要
Frosting on the coil of the air source heat pump (ASHP) significantly affects its performance. An accurate defrosting control method is essential for the ASHP unit. Here, a novel visual defrosting control method based on machine vision is proposed. The frosting degree of the unit is accurately obtained by frosting image analysis with digital image processing to achieve on-demand defrosting. Fractal dimension, frosting degree coefficient, and single-circuit frosting evenness value are introduced to evaluate the frosting degree of coil images. The image acquisition point is determined with confusion matrix. Based on this, the logical framework of the proposed method is constructed, in which the defrosting starting and termination conditions are set as the moment when the frosting degree coefficient is equal to 0.9 and 0, respectively. A multi-variable model of fractal dimension is fitted, which improves the generalization of the proposed method. Finally, comparative experiments are conducted between the proposed method and the traditional temperature-time (T-T) method in typical cases. The results indicate that the COP and total heating capacity increase by 11.8 %, 10.6 % and 7.4 %, 6.6 %, respectively, and the defrosting frequency is reduced by 75 %, which demonstrates dominant advantages of the proposed method in accuracy, energy-saving, and indoor thermal comfort management.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] New ideas on defrosting control of air-source heat pump
    Huang, XW
    Wang, RX
    Li, DY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 124 - 132
  • [2] Analysis of Air-Source Heat Pump System Based on Energy Storage for Defrosting
    Liu, Xuelai
    Zhang, Hongrui
    Wang, Lei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [3] Experiment design of the defrosting control method of the variable refrigerant flow air source heat pump
    Han, Xing
    Chen, Jianbo
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 162 - 165
  • [4] Control strategy and experimental study on a novel defrosting method for air-source heat pump
    Liang, Cai-Hua
    Zhang, Xiao-Song
    Li, Xiu-Wei
    Chen, Zhen-Qian
    APPLIED THERMAL ENGINEERING, 2010, 30 (8-9) : 892 - 899
  • [5] Feasibility and optimization of defrosting control method with differential pressure sensor for air source heat pump systems
    Chung, Yoong
    Na, Sun Ik
    Choi, Jongmin
    Kim, Min Soo
    APPLIED THERMAL ENGINEERING, 2019, 155 : 461 - 469
  • [6] A data-driven evaluating method on the defrosting effect of the air source heat pump system in Beijing
    Guo, Yanhua
    Shao, Shuangquan
    Geng, Xudong
    Li, Hao
    Wang, Zhichao
    Akkurt, Nevzat
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [7] Effect of PCM based heat exchanger for defrosting on performance of air source heat pump
    School of Municipal and Environment, Harbin Institute of Technology, Harbin 150090, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2009, 10 (908-912):
  • [8] A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump
    Long, Zhang
    Dong Jiankai
    Jiang Yiqiang
    Yang, Yao
    APPLIED ENERGY, 2014, 133 : 101 - 111
  • [9] The optimal defrosting condition of an air source heat pump based on entropy analysis
    Dong, Wei
    Li, Yongcun
    Zou, Shenghua
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 13176 - 13195
  • [10] Determination of the defrosting duration ratio for defrosting performance evaluation of air source heat pump
    Li, Zhaoyang
    Wei, Wenzhe
    Wang, Wei
    Sun, Yuying
    Wang, Shiquan
    Tang, Rui
    Lin, Yao
    Huang, Chengyang
    Deng, Shiming
    JOURNAL OF BUILDING ENGINEERING, 2024, 95