Admittance stability model and equivalent circuit analysis of three-phase AC systems in different coordinate systems

被引:0
|
作者
Hu, Zhe [1 ]
Han, Yang [1 ]
Zhang, Songling [1 ]
Yang, Ping [1 ]
Zalhaf, Amr S. [2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[2] Tanta Univ, Fac Engn, Elect Power & Machines Engn Dept, Tanta, Egypt
基金
中国国家自然科学基金;
关键词
admittance equivalence; converter system; eigenvalue; equivalent circuit; system stability;
D O I
10.1002/cta.4147
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, with a large number of distributed energy sources connected to the grid, the distribution network has shown a clear trend towards the use of power electronics. As a power conversion interface, the stability of the converter's interaction with the grid has received considerable attention. Adequate admittance (impedance) modeling of the three-phase grid-connected converter is a prerequisite for analyzing the stability and resonance characteristics of the grid-connected system. Understanding the internal mechanisms and proposing effective solutions are crucial to enable power systems to effectively cope with the impact of power electronics. Therefore, by studying the admittance equivalence relationship and equivalent circuit of three-phase AC systems in various coordinate systems, this paper focuses on solving the non-uniqueness problem of impedance admittance modeling of three-phase converter system. It is proposed that the input admittance of the three-phase asymmetrical system in the dq and fb rotating coordinate systems is a 2-order matrix and equivalent. The input admittance of the three-phase unbalanced system in the alpha beta and "12" static coordinate systems is a 4-order matrix and equivalent. From both theoretical analysis and simulation verification, it is shown that the number of eigenvalues of the three-phase asymmetrical system in the stationary coordinate system is twice that in the rotating coordinate system, and the overall damping of the system is improved. The control strategy based on the stationary coordinate system will make the system more stable. The second contribution of this paper is to establish the equivalent circuit of the three-phase symmetric converter system by the node admittance matrix and extend it to the multi-machine system to explain the system instability mechanism by the circuit resonance mechanism. Finally, the frequency coupling phenomenon is studied for the three-phase asymmetrical converter system, and it is explained that it cannot establish an equivalent circuit similar to the three-phase symmetrical converter system. The equivalent circuit model of the three-phase symmetrical converter system is proposed. The admittance model equivalence in the synchronous rotating coordinate system is explained by admittance eigenvalue, and stability margin of asymmetric system in rotating coordinate system is lower than that in stationary coordinate system by total damping of system. image
引用
收藏
页数:24
相关论文
共 50 条
  • [41] Anisotropy in three-phase transformer circuit model
    Elleuch, M
    Poloujadoff, M
    IEEE TRANSACTIONS ON MAGNETICS, 1997, 33 (05) : 4319 - 4326
  • [42] Linear Model of a Three-phase Circuit Characteristics
    Miroslaw, Wcislik
    2009 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL POWER QUALITY AND UTILISATION (EPQU 2009), 2009, : 82 - 87
  • [43] Determination Approach for the Parameters of Equivalent Circuit Model of Deep Saturated Three-Phase Integrative Transformers
    Wang, Yingying
    Shangguan, Yunqi
    Yuan, Jiansheng
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [44] EQUIVALENT CIRCUIT PARAMETERS AND OPERATING PERFORMANCES OF THE THREE-PHASE ASYNCHRONOUS MOTOR
    Mihalache, Marin
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2010, 55 (01): : 32 - 41
  • [45] A Single-Stage Three-Phase AC-AC Converter for Inductive Power Transfer Systems
    Moghaddami, Masood
    Moghadasi, Amir
    Sarwat, Arif I.
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [46] Stability analysis and concept extension of harmonic decoupling network for the three-phase grid synchronization systems
    Luo, Zhaoxu
    Su, Mei
    Sun, Yao
    Wang, Hui
    Yuan, Wenbin
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2017, 89 : 1 - 10
  • [47] Experimental Verification of the Generalized Nyquist Stability Criterion for Balanced Three-phase Ac Systems in the Presence of Constant Power Loads
    Wen, Bo
    Boroyevich, Dushan
    Mattavelli, Paolo
    Shen, Zhiyu
    Burgos, Rolando
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 3926 - 3933
  • [48] Dynamic on-line measurement of equivalent parameters of three-phase systems for harmonic frequencies
    Czarnecki, LS
    Staroszczyk, Z
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 1996, 6 (05): : 329 - 336
  • [49] Memristive Devices In Three-Phase Systems
    Zegarmistrz, Piotr
    Garda, Bartlomiej
    PRZEGLAD ELEKTROTECHNICZNY, 2020, 96 (01): : 11 - 14
  • [50] Gelation in three-phase disperse systems
    Buryanov, Alexsandr
    Belov, Vladimir
    Petropavlovskaya, Victoria
    Novichencova, Tatyana
    Rozovskaya, Tamara
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 1306 - +