Admittance stability model and equivalent circuit analysis of three-phase AC systems in different coordinate systems

被引:0
|
作者
Hu, Zhe [1 ]
Han, Yang [1 ]
Zhang, Songling [1 ]
Yang, Ping [1 ]
Zalhaf, Amr S. [2 ]
机构
[1] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
[2] Tanta Univ, Fac Engn, Elect Power & Machines Engn Dept, Tanta, Egypt
基金
中国国家自然科学基金;
关键词
admittance equivalence; converter system; eigenvalue; equivalent circuit; system stability;
D O I
10.1002/cta.4147
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, with a large number of distributed energy sources connected to the grid, the distribution network has shown a clear trend towards the use of power electronics. As a power conversion interface, the stability of the converter's interaction with the grid has received considerable attention. Adequate admittance (impedance) modeling of the three-phase grid-connected converter is a prerequisite for analyzing the stability and resonance characteristics of the grid-connected system. Understanding the internal mechanisms and proposing effective solutions are crucial to enable power systems to effectively cope with the impact of power electronics. Therefore, by studying the admittance equivalence relationship and equivalent circuit of three-phase AC systems in various coordinate systems, this paper focuses on solving the non-uniqueness problem of impedance admittance modeling of three-phase converter system. It is proposed that the input admittance of the three-phase asymmetrical system in the dq and fb rotating coordinate systems is a 2-order matrix and equivalent. The input admittance of the three-phase unbalanced system in the alpha beta and "12" static coordinate systems is a 4-order matrix and equivalent. From both theoretical analysis and simulation verification, it is shown that the number of eigenvalues of the three-phase asymmetrical system in the stationary coordinate system is twice that in the rotating coordinate system, and the overall damping of the system is improved. The control strategy based on the stationary coordinate system will make the system more stable. The second contribution of this paper is to establish the equivalent circuit of the three-phase symmetric converter system by the node admittance matrix and extend it to the multi-machine system to explain the system instability mechanism by the circuit resonance mechanism. Finally, the frequency coupling phenomenon is studied for the three-phase asymmetrical converter system, and it is explained that it cannot establish an equivalent circuit similar to the three-phase symmetrical converter system. The equivalent circuit model of the three-phase symmetrical converter system is proposed. The admittance model equivalence in the synchronous rotating coordinate system is explained by admittance eigenvalue, and stability margin of asymmetric system in rotating coordinate system is lower than that in stationary coordinate system by total damping of system. image
引用
收藏
页数:24
相关论文
共 50 条
  • [1] An Equivalent Circuit Formulation for Three-Phase Power Flow Analysis of Distribution Systems
    Jereminov, Marko
    Bromberg, David M.
    Pandey, Amritanshu
    Li, Xin
    Hug, Gabriela
    Pileggi, Larry
    2016 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2016,
  • [2] The Essence of Three-Phase AC/AC Converter Systems
    Kolar, J. W.
    Friedli, I.
    Krismer, F.
    Round, S. D.
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (09): : 14 - 29
  • [3] The Essence of Three-Phase AC/AC Converter Systems
    Kolar, J. W.
    Friedli, T.
    Krismer, F.
    Round, S. D.
    2008 13TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-5, 2008, : 27 - 42
  • [4] Stability criterion for three-phase AC power systems with converter load
    Liu, Z. (zeng.liu@ieee.org), 2012, Chinese Society for Electrical Engineering (32):
  • [5] Methods for Stability Analysis of Unbalanced Three-Phase Systems
    Cespedes, Mauricio
    Sun, Jian
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 3090 - 3097
  • [6] A Set of Independent Admittance Bases for Decoupled Analysis of Unbalanced Three-phase Systems
    Li, Zhen
    Wong, Siu-Chung
    Tse, Chi K.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2013, : 469 - 472
  • [7] A Digital Twin Approach for Online Impedance-Based Stability Analysis of Three-Phase AC Systems
    Diz, Sergio de Lopez
    Lopez, Roberto Martin
    Sanchez, Francisco Javier Rodriguez
    Pena, Emilio Jose Bueno
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (12) : 16845 - 16856
  • [8] Hardware-in-the-Loop Methods for Stability Analysis of Multiple Parallel Inverters in Three-Phase AC Systems
    Alenius, Henrik
    Roinila, Tomi
    Luhtala, Roni
    Messo, Tuomas
    Burstein, Andrew
    de Jong, Erik
    Fabian, Alejandra
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (06) : 7149 - 7158
  • [9] Three-Phase AC Arc Plasma Systems: A Review
    Fulcheri, Laurent
    Fabry, Frederic
    Takali, Sabri
    Rohani, Vandad
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2015, 35 (04) : 565 - 585
  • [10] Three-Phase AC Arc Plasma Systems: A Review
    Laurent Fulcheri
    Fréderic Fabry
    Sabri Takali
    Vandad Rohani
    Plasma Chemistry and Plasma Processing, 2015, 35 : 565 - 585