Joey: Supporting Kangaroo Mother Care with Computational Fabrics

被引:7
作者
Shao, Qijia [1 ]
Liu, Jiting [1 ]
Bejerano, Emily [2 ]
Colman, Ho Man [1 ]
Nie, Jingping [2 ]
Jiang, Xiaofan [2 ]
Zhou, Xia [1 ]
机构
[1] Columbia Univ, Dept Comp Sci, New York, NY 10027 USA
[2] Columbia Univ, Dept Elect Engn, New York, NY 10027 USA
来源
PROCEEDINGS OF THE 2024 THE 22ND ANNUAL INTERNATIONAL CONFERENCE ON MOBILE SYSTEMS, APPLICATIONS AND SERVICES, MOBISYS 2024 | 2024年
基金
美国国家科学基金会;
关键词
Computational Fabrics; Kangaroo Mother Care; Electrocardiogram; Vital Sign Monitoring; FETAL ECG EXTRACTION; RESPIRATORY RATE; ELECTROCARDIOGRAM EXTRACTION; INFANTS; SENSORS; BODY; ALGORITHMS; ARRHYTHMIA; IMPEDANCE;
D O I
10.1145/3643832.3661867
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Kangaroo Mother Care (KMC), involving chest-to-chest skin contact between an infant and caregiver, is proven to be an effective intervention for preterm and full-term infants. Accurate monitoring of KMC duration and infant's vital signs during KMC is clinically important. Existing monitoring methods, however, rely on manual efforts and require rigid sensors or wires/electrodes on the infant's body. We propose Joey, a fabric-based approach to continuously monitor KMC duration and two vital signs essential to an infant's well-being: heart rate and respiration rate. Joey is a soft fabric necklace worn by the caregiver. It leverages the transmission of electrocardiogram (ECG) signals across individuals during skin-to-skin contact. With a minimalist fabric sensor structure, Joey measures KMC duration via the presence of mixed ECG signals. It then isolates the infant's ECG from this mixture with a proposed signal extraction algorithm and employs a diffusion-based denoising model to mitigate motion artifacts, enabling reliable inference of infant's vital signs. We fabricate Joey prototypes with off-the-shelf hardware and evaluate its performance with user studies. Results demonstrate that Joey achieves an average F1 score of 96% for KMC duration measurement, and clinically-acceptable accuracy in infant's vital sign estimation with a mean absolute error of 2.3 beats per minute and 2.9 breaths per minute in estimating heart rate and respiration rate. Clinical interviews further confirm the usability of Joey's sensing fabric for infant skin. A demonstration video of Joey is available at: mobilex.cs.columbia.edu/joey
引用
收藏
页码:237 / 251
页数:15
相关论文
共 122 条
[1]   Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review [J].
Acar, Gizem ;
Ozturk, Ozberk ;
Golparvar, Ata Jedari ;
Elboshra, Tamador Alkhidir ;
Bohringer, Karl ;
Yapici, Murat Kaya .
ELECTRONICS, 2019, 8 (05)
[2]   Wavelet transforms and the ECG: a review [J].
Addison, PS .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) :R155-R199
[3]  
[Anonymous], 2023, MightySat Fingertip Pulse Oximeter
[4]  
[Anonymous], 2023, Hypoallergenic adhesives
[5]  
[Anonymous], 2023, Cyton biosensing board (8-channels)
[6]  
[Anonymous], 2023, Setting up for ECG
[7]  
[Anonymous], 2023, Stainless thin conductive thread
[8]  
[Anonymous], 2023, Hiasan black rectangle tablecloth-waterproof wrinkle resistant washable fabric table cloth for dining room kitchen and outdoor use
[9]  
[Anonymous], 2023, Quark c12x-t12x ecg monitor
[10]  
[Anonymous], 2023, Self-adhesive waterproof fabric patch for sofas, tents, furniture,tote bags, car seats