Finite Element Analysis of the Effect of Femoral Prosthesis Varus and Valgus Angle Installation on the Lateral Compartment in Unicompartmental Knee Arthroplasty

被引:0
作者
Wang, Yonggui [1 ,2 ]
Xu, Chongyang [1 ]
Yang, Bo [1 ]
Yu, Fei [1 ]
Guo, Ai [1 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Dept Orthoped Surg, 95 Yongan Rd, Beijing 100050, Peoples R China
[2] Hubei Univ Med, Xiangyang Peoples Hosp 1, Dept Orthoped, Xiangyang, Peoples R China
关键词
anteromedial osteoarthritis (AMOA); femoral prosthesis; biomechanical research; TIBIAL COMPONENT; MOBILE-BEARING; INCLINATION; REVISION; LIGAMENT; STRESS; SLOPE;
D O I
10.1272/jnms.JNMS.2024_91-110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study used finite element analysis (FEA) to investigate the effect of varus and valgus angle on the lateral compartment in unicompartmental knee arthroplasty (UKA). Methods: One patient who underwent UKA was enrolled as the subject. Thirteen working conditions of the femoral prosthesis were simulated at varus and valgus angles of 0 degrees, 2 degrees, 4 degrees, 6 degrees, 8 degrees, 10 degrees, and 12 degrees. A load of 1,000 N was applied downward along the mechanical axis of the femur, and the highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage in each model were recorded. The six highest points were used to calculate the mean value. Results: The highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage increased with an increase in the femoral prosthesis varus/valgus angle. As compared with the standard position of the femoral prosthesis, there was no significant difference in the surface stress values of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus and tibial lateral plateau cartilage when the femoral prosthesis varus/valgus angle was less than 4 degrees (p > 0.05). In addition, the stress magnitude on the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage significantly increased when the femoral prosthesis varus/valgus angle was greater than 4 degrees (p < 0.001). Conclusions: The optimal femoral prosthesis varus/valgus angle in UKA was less than 4 degrees.
引用
收藏
页码:88 / 98
页数:11
相关论文
共 34 条
  • [1] Progression of osteoarthritis and reoperation in unicompartmental knee arthroplasty: A comparison of national joint registries
    Castiello, Emanuela
    Affatato, Saverio
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (03) : 203 - 207
  • [2] Evaluation of the mechanical properties of posterolateral structures and supporting posterolateral instability of the knee
    Chun, Yong-Min
    Kim, Sung-Jae
    Kim, Hyoung-Sik
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2008, 26 (10) : 1371 - 1376
  • [3] Outcomes of a Fixed-Bearing, Medial, Cemented Unicondylar Knee Arthroplasty Design: Survival Analysis and Functional Score of 460 Cases
    de Grave, Philip Winnock
    Barbier, Justine
    Luyckx, Thomas
    Ryckaert, Alexander
    Gunst, Paul
    Van den Daelen, Luc
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (09) : 2792 - 2799
  • [4] Optimization of sagittal and coronal planes with robotic-assisted unicompartmental knee arthroplasty
    Gaudiani, Michael A.
    Nwachukwu, Benedict U.
    Baviskar, Jayesh V.
    Sharma, Mrinal
    Ranawat, Anil S.
    [J]. KNEE, 2017, 24 (04) : 837 - 843
  • [5] Effects of increasing tibial slope on the biomechanics of the knee
    Giffin, JR
    Vogrin, TM
    Zantop, T
    Woo, SLY
    Harner, CD
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (02) : 376 - 382
  • [6] Unicondylar Knee Arthroplasty Has Fewer Complications but Higher Revision Rates Than Total Knee Arthroplasty in a Study of Large United States Databases
    Hansen, Erik N.
    Ong, Kevin L.
    Lau, Edmund
    Kurtz, Steven M.
    Lonner, Jess H.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (08) : 1617 - 1625
  • [7] The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty
    Iesaka, K
    Tsumura, H
    Sonoda, H
    Sawatari, T
    Takasita, M
    Torisu, T
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (07) : 969 - 974
  • [8] Biomechanical Effects of Different Varus and Valgus Alignments in Medial Unicompartmental Knee Arthroplasty
    Innocenti, Bernardo
    Pianigiani, Silvia
    Ramundo, Gaetano
    Thienpont, Emmanuel
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (12) : 2685 - 2691
  • [9] The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty
    Inoue, Shinji
    Akagi, Masao
    Asada, Shigeki
    Mori, Shigeshi
    Zaima, Hironori
    Hashida, Masahiko
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (09) : 2025 - 2030
  • [10] Biomechanical effects of posterior tibial slope on unicompartmental knee arthroplasty using finite element analysis
    Kang, Kyoung-Tak
    Park, Joon-Hee
    Koh, Yong-Gon
    Shin, Jaewon
    Park, Kwan Kyu
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2019, 30 (02) : 133 - 144