Background: Digital templating software can be used for preoperative implant size prediction in total knee arthroplasty (TKA). However, the accuracy of its prediction is reported to be low, and the impact of radiograph quality is unclear. Purpose: To investigate on the application of lateral knee radiograph quality criteria for knee rotation (KR) and knee abduction/adduction (KA) and their impact on the accuracy of final implant size prediction achieved by preoperative digital templating for TKA. Methods: A total of 191 radiographs of patients undergoing TKA were allocated into four groups according to their KR as measured at the posterior femoral condyles and their KA as measured at the distal femoral condyles on lateral knee radiographs: group A (KR <= 5 mm, KA <= 5 mm), B1 (KR > 5 mm, KA <= 5 mm), B2 (KR <= 5 mm, KA > 5 mm) and B3 (KR > 5 mm, KA > 5 mm). Preoperative templating of femoral and tibial implant size using digital templating software was carried out by two observers. Correlation coefficients (CCs) between planned and final implant size, percentage of cases with planned to final size match as well as percentage of cases within +/- 1 and +/- 2 of planned to final size were reported according to groups. Results: Group A showed the highest percentage of cases with matching planned to final femoral implant size (45%) and the highest percentage of cases with +/- 1 planned to final implant size (86%) as compared to B1 (match 28%, +/- 1 84%), B2 (match 41%, +/- 1 84%) and B3 (match 35%, +/- 1 78%). CCs for planned to final implant size were reported at >0.75 in all groups. No statistically significant difference in the CCs of planned to final implant size amongst groups was found. Conclusion: The accuracy of implant size prediction achieved by preoperative digital templating for TKA is neither affected by KR nor KA on lateral knee radiographs.
引用
收藏
页数:7
相关论文
共 24 条
  • [1] Inventory management of surgical supplies and sterile instruments in hospitals: a literature review
    Ahmadi, Ehsan
    Masel, Dale T.
    Metcalf, Ashley Y.
    Schuller, Kristin
    [J]. HEALTH SYSTEMS, 2019, 8 (02) : 134 - 151
  • [2] Tibial Component Undersizing Is Related to High Degrees of Implant Migration Following Cementless Total Knee Arthroplasty A Study of Radiostereometric Analysis Data for 111 Patients with 2-Year Follow-up
    Andersen, Mikkel Rathsach
    Winther, Nikolaj
    Lind, Thomas
    Schroder, Henrik
    Flivik, Gunnar
    Petersen, Michael Mork
    [J]. JBJS OPEN ACCESS, 2023, 8 (03)
  • [3] The role of pre-operative templating in primary total knee replacement
    Arora, J
    Sharma, S
    Blyth, M
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (03) : 187 - 189
  • [4] Aslam Nadim, 2004, Acta Orthop Belg, V70, P560
  • [5] Effects of Malpositioning of the Knee on Radiographic Measurements: The Influence of Adduction, Abduction, and Malrotation on Measured Tibial Slope
    Bixby, Elise C.
    Tedesco, Liana J.
    Confino, Jamie E.
    Mueller, John D.
    Redler, Lauren H.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2023, 11 (06)
  • [6] Oversizing the tibial component in TKAs: incidence, consequences and risk factors
    Bonnin, Michel P.
    Saffarini, Mo
    Shepherd, David
    Bossard, Nadine
    Dantony, Emmanuelle
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2532 - 2540
  • [7] Can 3D surgical planning and patient specific instrumentation reduce hip implant inventory? A prospective study
    Di Laura, Anna
    Henckel, Johann
    Hothi, Harry
    Hart, Alister
    [J]. 3D PRINTING IN MEDICINE, 2020, 6 (01)
  • [8] 2D versus 3D templating in total knee arthroplasty
    Ettinger, Max
    Claassen, Leif
    Paes, Peter
    Calliess, Tilman
    [J]. KNEE, 2016, 23 (01) : 149 - 151
  • [9] Anthropometric measurements of the human knee: Correlation to the sizing of current knee arthroplasty systems
    Hitt, K
    Shurman, JR
    Greene, K
    McCarthy, J
    Moskal, J
    Hoeman, T
    Mont, MA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 115 - 122
  • [10] Effect of Training Level on Accuracy of Digital Templating in Primary Total Hip and Knee Arthroplasty
    Hsu, Andrew R.
    Kim, Jeffrey D.
    Bhatia, Sanjeev
    Levine, Brett R.
    [J]. ORTHOPEDICS, 2012, 35 (02) : E179 - E183