Enhancing safety in hydrogen refuelling stations: Computational analysis of hydrogen explosion hazards

被引:3
作者
Patel, Parth [1 ]
Garaniya, Vikram [1 ,2 ]
Baalisampang, Til [1 ]
Arzaghi, Ehsan [1 ,3 ]
Abbassi, Rouzbeh [4 ]
Salehi, Fatemeh [4 ]
机构
[1] Univ Tasmania, Coll Sci & Engn, Australian Maritime Coll, Launceston, Australia
[2] RMIT Univ, Sch Engn, Melbourne, Australia
[3] Queensland Univ Technol, Fac Engn, Sch Mech Med & Proc Engn, Brisbane, Qld, Australia
[4] Macquarie Univ, Sch Engn, Sydney, NSW 2109, Australia
关键词
computational fluid dynamics (CFD); high-pressure hydrogen release; hydrogen explosion; hydrogen refuelling station; NUMERICAL-SIMULATION; RISK-ASSESSMENT; RELEASE; LEAKAGE; AIR; DISPERSION; DIFFUSION;
D O I
10.1002/cjce.25376
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper aims to enhance the understanding of hydrogen explosions in hydrogen refuelling stations and evaluate associated risk factors using computational fluid dynamics simulations. The model is first validated against the measured data for hydrogen dispersion and explosion. Different scenarios are then modelled to understand the ignition timing and location. The study estimates acceptable distances to minimize asset damage and human injury from explosion incidents. It has been found that higher wind speeds lead to faster and more extensive dispersion of the hydrogen gas released during a leak. In addition, since strong wind can act as a powerful driving force for the shock wave, the impact of the explosion is found to be less. Interestingly, moving the source of ignition to regions with higher hydrogen concentration has a marginal impact on overpressure and temperature; however, the blockage ratio can significantly amplify the overpressure. It is found that cases with high blockage, including storage room, and cases with large volumes of flammable cloud, including leakage from compressor towards the ground, have the highest hazards. The findings will provide valuable insights into fire and explosion prevention in various areas of hydrogen refuelling stations and contribute to safer hydrogen infrastructure construction.
引用
收藏
页码:82 / 97
页数:16
相关论文
共 43 条
[1]   Review of hydrogen safety during storage, transmission, and applications processes [J].
Abohamzeh, Elham ;
Salehi, Fatemeh ;
Sheikholeslami, Mohsen ;
Abbassi, Rouzbeh ;
Khan, Faisal .
JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2021, 72
[2]   Simulation of turbulent explosion of hydrogen-air mixtures [J].
Ahmed, I. ;
Swaminathan, N. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (17) :9562-9572
[3]   A literature review on hydrogen refuelling stations and infrastructure. Current status and future prospects [J].
Apostolou, D. ;
Xydis, G. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2019, 113
[4]  
Assael M.J., 2010, Fires, explosions, and toxic gas dispersions: effects calculation and risk analysis
[5]   Modelling an integrated impact of fire, explosion and combustion products during transitional events caused by an accidental release of LNG [J].
Baalisampang, Til ;
Abbassi, Rouzbeh ;
Garaniya, Vikram ;
Khan, Faisal ;
Dadashzadeh, Mohammad .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2019, 128 :259-272
[6]   The effect of gas jets on the explosion dynamics of hydrogen-air mixtures [J].
Chang, Xinyu ;
Bai, Chunhua ;
Zhang, Bo .
PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2022, 162 :384-394
[7]  
Chenoweth D., 1983, GASTRANSFER ANAL SEC
[8]   Analysis of the fire hazard and leakage explosion simulation of hydrogen fuel cell vehicles [J].
Cui, Shaoqi ;
Zhu, Guoqing ;
He, Lu ;
Wang, Xinyu ;
Zhang, Xiaojin .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41
[9]  
Ehrhart BD, 2020, Hydrogen Refueling Reference Station Lot Size Analysis for Urban Sites
[10]  
Friedrich A., 2007, EXPT STUDY JETFORMED