Transradial carotid artery stenting using double layer micromesh stent and novel post-dilation balloon with integrated embolic protection

被引:2
|
作者
Petkoska, Danica [1 ]
Zafirovska, Biljana [1 ]
Vasilev, Ivan [1 ]
Saylors, Elizabeth [2 ]
Sachar, Ravish [3 ]
Kedev, Sasko [1 ,4 ]
机构
[1] Univ Ss Cyril & Methodas, Univ Clin Cardiol, Med Fac, Skopje, North Macedonia
[2] Contego Med LLC, Raleigh, NC USA
[3] Univ N Carolina, North Carolina Heart & Vasc, UNC REX Healthcare, Raleigh, NC USA
[4] Univ St Cyril & Methodius, Univ Clin Cardiol, Fac Med, Intervent Cardiol Dept, Mother Teresa 17, Skopje 1000, North Macedonia
关键词
Cerebral embolic protection; Paladin device; Transradial access; Carotid stenosis; Carotid stenting; Double-layer micromesh stent; CEREBRAL PROTECTION; HIGH-RISK; REVASCULARIZATION ENDARTERECTOMY; CLINICAL-EXPERIENCE; PLAQUE PROTRUSION; PREVENTION; EMBOLIZATION; ANGIOPLASTY; DISTAL; TRIAL;
D O I
10.1016/j.carrev.2024.01.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The highest rate of embolization during carotid artery stenting occurs during post-dilation. We evaluated the ability of the Paladin system (Contego Medical, Raleigh, NC), a novel PTA balloon with an integrated 40-mu m pore filter, to collect microemboli that may pass into the cerebral circulation when used during post-dilation. Methods: 25 symptomatic patients underwent transradial CAS using the Paladin system in conjunction with the Roadsaver (Terumo Corporation, Tokyo, Japan) micromesh stent. No additional embolic protection was used. The Paladin filters were collected following the procedure and preserved in formalin for histological analysis. The contents were evaluated for particle count and size. Subjects were followed for 30 days and evaluated for major cardiac adverse events (death, stroke and MI). Secondary endpoints included procedure success, device success, access site complications according to EASY score classification, major vascular or ischemic complications at follow up and in-stent restenosis rate evaluated with duplex ultrasound. Results: Mean age of patients was 68,5 years. Type 2 aortic arch was present in 77 % of patients and type 1 and type 3 in 12 % and 11 % of patients respectively. Procedural and device success was obtained in all cases without complications. The 30-day MAE rate was 0 %. Twenty-three filters underwent histological analysis. Microscopic debris was present in 100 % of filters, and 75 % of particles were less than 100 mu m in size. The mean number of particles per filter was 3352 +/- 1567 (IQR 4300-2343), and the mean number of particles between 40-100 mu m per filter was 2499 +/- 1240 (IQR 3227-1575). Conclusion: CAS through radial approach can be safely and effectively performed using the IEP technology Paladin device and double-layer micromesh Roadsaver stent. This strategy can simplify the procedure and decrease periprocedural complications and procedural time.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 46 条
  • [41] The CAPTURE registry: Predictors of outcomes in carotid artery stenting with embolic protection for high surgical risk patients in the early post-approval setting
    Gray, William A.
    Yadav, Jay S.
    Verta, Patrick
    Scicli, Andrea
    Fairman, Ronald
    Wholey, Mark
    Hopkins, L. Nelson
    Atkinson, Richard
    Raabe, Rod
    Barnwell, Stanley
    Green, Richard
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (07) : 1025 - 1033
  • [42] Safety and efficacy of an open-cell stent and double-balloon protection for unstable plaques: analysis of 184 consecutive carotid artery stentings
    Funakoshi, Yusuke
    Imamura, Hirotoshi
    Tani, Shoichi
    Adachi, Hidemitsu
    Fukumitsu, Ryu
    Sunohara, Tadashi
    Omura, Yoshihiro
    Matsui, Yuichi
    Sasaki, Natsuhi
    Fukuda, Tatsumaru
    Akiyama, Ryo
    Horiuchi, Kazufumi
    Kajiura, Shinji
    Shigeyasu, Masashi
    Iihara, Koji
    Sakai, Nobuyuki
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2020, 12 (08) : 758 - +
  • [43] Efficacy of post-dilatation during carotid artery stenting for unstable plaque using closed-cell design stent evaluated by optical coherence tomography
    Harada, Kei
    Kajihara, Masahito
    Sankoda, Yukihiro
    Taniguchi, Syunsuke
    JOURNAL OF NEURORADIOLOGY, 2019, 46 (06) : 384 - 389
  • [44] Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial
    Ahlhelm, Frank
    Kaufmann, Ralf
    Ahlhelm, Dirk
    Ong, Mai Fang
    Roth, Christian
    Reith, Wolfgang
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (05) : 1019 - 1027
  • [45] Retrograde three-dimensional rotational angiography: A novel method for the detection of plaque protrusion during carotid artery stenting under continuous distal balloon protection
    Hosoo, Hisayuki
    Tsuruta, Wataro
    Hamada, Yusuke
    Katsumata, Masahiro
    Ishigami, Daiichiro
    Ishikawa, Eiichi
    Matsumaru, Yuji
    Matsumura, Akira
    INTERVENTIONAL NEURORADIOLOGY, 2020, 26 (03) : 316 - 320
  • [46] Endovascular Treatment of 2 Synchronous Extracranial Carotid Artery Aneurysms Using Stent-Assisted Coil Embolization and Double Bare-Metal Stenting
    Han, Daniel K.
    Tadros, Rami O.
    Chung, Christine
    Patel, Aman
    Marin, Michael L.
    Faries, Peter L.
    VASCULAR AND ENDOVASCULAR SURGERY, 2016, 50 (02) : 102 - 106