Transradial carotid artery stenting using double layer micromesh stent and novel post-dilation balloon with integrated embolic protection

被引:2
|
作者
Petkoska, Danica [1 ]
Zafirovska, Biljana [1 ]
Vasilev, Ivan [1 ]
Saylors, Elizabeth [2 ]
Sachar, Ravish [3 ]
Kedev, Sasko [1 ,4 ]
机构
[1] Univ Ss Cyril & Methodas, Univ Clin Cardiol, Med Fac, Skopje, North Macedonia
[2] Contego Med LLC, Raleigh, NC USA
[3] Univ N Carolina, North Carolina Heart & Vasc, UNC REX Healthcare, Raleigh, NC USA
[4] Univ St Cyril & Methodius, Univ Clin Cardiol, Fac Med, Intervent Cardiol Dept, Mother Teresa 17, Skopje 1000, North Macedonia
关键词
Cerebral embolic protection; Paladin device; Transradial access; Carotid stenosis; Carotid stenting; Double-layer micromesh stent; CEREBRAL PROTECTION; HIGH-RISK; REVASCULARIZATION ENDARTERECTOMY; CLINICAL-EXPERIENCE; PLAQUE PROTRUSION; PREVENTION; EMBOLIZATION; ANGIOPLASTY; DISTAL; TRIAL;
D O I
10.1016/j.carrev.2024.01.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The highest rate of embolization during carotid artery stenting occurs during post-dilation. We evaluated the ability of the Paladin system (Contego Medical, Raleigh, NC), a novel PTA balloon with an integrated 40-mu m pore filter, to collect microemboli that may pass into the cerebral circulation when used during post-dilation. Methods: 25 symptomatic patients underwent transradial CAS using the Paladin system in conjunction with the Roadsaver (Terumo Corporation, Tokyo, Japan) micromesh stent. No additional embolic protection was used. The Paladin filters were collected following the procedure and preserved in formalin for histological analysis. The contents were evaluated for particle count and size. Subjects were followed for 30 days and evaluated for major cardiac adverse events (death, stroke and MI). Secondary endpoints included procedure success, device success, access site complications according to EASY score classification, major vascular or ischemic complications at follow up and in-stent restenosis rate evaluated with duplex ultrasound. Results: Mean age of patients was 68,5 years. Type 2 aortic arch was present in 77 % of patients and type 1 and type 3 in 12 % and 11 % of patients respectively. Procedural and device success was obtained in all cases without complications. The 30-day MAE rate was 0 %. Twenty-three filters underwent histological analysis. Microscopic debris was present in 100 % of filters, and 75 % of particles were less than 100 mu m in size. The mean number of particles per filter was 3352 +/- 1567 (IQR 4300-2343), and the mean number of particles between 40-100 mu m per filter was 2499 +/- 1240 (IQR 3227-1575). Conclusion: CAS through radial approach can be safely and effectively performed using the IEP technology Paladin device and double-layer micromesh Roadsaver stent. This strategy can simplify the procedure and decrease periprocedural complications and procedural time.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 46 条
  • [21] Drug-Coated Balloon Dilation Before Carotid Artery Stenting of Post-Carotid Endarterectomy Restenosis
    Piccoli, Gianluca
    Biondi-Zoccai, Giuseppe
    Gavrilovic, Vladimir
    Radici, Viviana
    Cancelli, Iacopo
    Frigatti, Paolo
    Frati, Giacomo
    Marullo, Antonino G. M.
    Divis, Paolo
    Gasparini, Daniele
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (02) : 212 - 216
  • [22] Carotid Artery Stenting With Proximal Embolic Protection via a Transradial or Transbrachial Approach: Pushing the Boundaries of the Technique While Maintaining Safety and Efficacy
    Montorsi, Piero
    Galli, Stefano
    Ravagnani, Paolo M.
    Tresoldi, Simone
    Teruzzi, Giovanni
    Caputi, Luigi
    Trabattoni, Daniela
    Fabbiocchi, Franco
    Calligaris, Giuseppe
    Grancini, Luca
    Lualdi, Alessandro
    de Martini, Stefano
    Bartorelli, Antonio L.
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (04) : 549 - 560
  • [23] Contemporary Results of Carotid Artery Stenting Using Low-Profile Dual-Metal Layer Nitinol Micromesh Stents in Relation to Single-Layer Carotid Stents
    Kahlberg, Andrea
    Bilman, Victor
    Ardita, Vincenzo
    Mascia, Daniele
    Bertoglio, Luca
    Rinaldi, Enrico
    Melissano, Germano
    Chiesa, Roberto
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (05) : 726 - 736
  • [24] Postoperative ischemic events in patients undergoing carotid artery stenting using algorithmic selection for embolic protection
    Kawabata, Yasuhiro
    Nakajima, Norio
    Miyake, Hidenori
    Fukuda, Shunichi
    Tsukahara, Tetsuya
    NEURORADIOLOGY JOURNAL, 2019, 32 (04) : 294 - 302
  • [25] Efficacy of Post-Dilatation during Carotid Artery Stenting for Unstable Plaque Using a Double-Layer Stent Evaluated by OFDI
    Kiyosawa, Ryuichiro
    Saito, Takaya
    Harada, Kei
    Yamada, Shingo
    JOURNAL OF NEUROENDOVASCULAR THERAPY, 2022, 16 (08) : 395 - 401
  • [26] New Distal Balloon Protection System for Transradial Carotid Artery Stenting After Percusurge Guardwire Withdrawal: Jailbreak Technique
    Yamazaki, Daisuke
    Hanaoka, Yoshiki
    Koyama, Jun-ichi
    Horiuchi, Tetsuyoshi
    WORLD NEUROSURGERY, 2022, 168 : 58 - 62
  • [27] Transfemoral Stenting of Stenoses at the Common Carotid Artery Origin Using an Anchoring Technique With a Balloon Protection Device
    Tsuji, Kiyoshi
    Fukawa, Norihito
    Nakagawa, Nobuhiro
    Watanabe, Akira
    Murakami, Saori
    Nagatsuka, Kazuhiro
    Nakano, Naoki
    Kataoka, Kazuo
    Kato, Amami
    NEUROSURGERY, 2016, 79 (04) : 598 - 603
  • [28] Double balloon protection during carotid artery stenting for vulnerable carotid stenosis reduces the incidence of new brain lesions
    Masahito Nakazaki
    Tadashi Nonaka
    Akira Takahashi
    Yasuyuki Yonemasu
    Tatsufumi Nomura
    Toshiyuki Onda
    Osamu Honda
    Yuji Hashimoto
    Hirofumi Ohnishi
    Masanori Sasaki
    Masahiko Daibo
    Osamu Honmou
    Acta Neurochirurgica, 2016, 158 : 1377 - 1386
  • [29] STANDARD CAROTID ENDARTERECTOMY VERSUS CAROTID ARTERY STENTING WITH CLOSED-CELL STENT DESIGN AND DISTAL EMBOLIC PROTECTION: DOES THE AGE MATTER?
    Peluso, A.
    Turchino, D.
    Petrone, A.
    Giribono, A. M.
    Bracale, R.
    Del Guercio, L.
    Bracale, U. M.
    TRANSLATIONAL MEDICINE AT UNISA, 2019, 19 : 60 - 65
  • [30] Safety and Efficacy of Carotid Artery Stenting with the CGuard Double-layer Stent in Acute Ischemic Stroke
    Klail, Tomas
    Kurmann, Christoph
    Kaesmacher, Johannes
    Mujanovic, Adnan
    Piechowiak, Eike, I
    Dobrocky, Tomas
    Pilgram-Pastor, Sara
    Scutelnic, Adrian
    Heldner, Mirjam R.
    Gralla, Jan
    Mordasini, Pasquale
    CLINICAL NEURORADIOLOGY, 2023, 33 (01) : 237 - 244