Study of V2CT x -MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein

被引:5
作者
Tasic, Nikola [1 ]
Konjevic, Ivan [1 ,2 ]
Lobato, Alnilan [1 ,3 ]
Metarapi, Dino [1 ]
Finsgar, Matjaz [4 ]
Oliveira, Filipa M. [5 ]
Sofer, Zdenek [5 ]
Gusmao, Rui [5 ]
Zhang, Xueji [6 ]
Hocevar, Samo B. [1 ]
机构
[1] Natl Inst Chem, Dept Analyt Chem, Ljubljana 1000, Slovenia
[2] Univ Ljubljana, Fac Chem & Chem Technol, Ljubljana 1000, Slovenia
[3] Int Postgrad Sch Jozef Stefan, Ljubljana 1000, Slovenia
[4] Univ Maribor, Fac Chem & Chem Engn, Maribor 2000, Slovenia
[5] Univ Chem & Technol Prague, Dept Inorgan Chem, 6 Dejvice, Prague 16628, Czech Republic
[6] Shenzhen Univ Hlth Sci Ctr, Sch Biomed Engn, Shenzhen 518054, Guangdong, Peoples R China
关键词
V2CT x MXene; SARS-CoV-2; spike protein; immunosensor; electrochemical; impedimetric; NAFION; GLUTARALDEHYDE; COMPOSITE; IMMUNOASSAY;
D O I
10.1021/acsami.4c04567
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.
引用
收藏
页码:30196 / 30208
页数:13
相关论文
共 61 条
[1]   Evaluation and clinical implications of the time to a positive results of antigen testing for SARS-CoV-2 [J].
Akashi, Yusaku ;
Kiyasu, Yoshihiko ;
Takeuchi, Yuto ;
Kato, Daisuke ;
Kuwahara, Miwa ;
Muramatsu, Shino ;
Ueda, Atsuo ;
Notake, Shigeyuki ;
Nakamura, Koji ;
Ishikawa, Hiroichi ;
Suzuki, Hiromichi .
JOURNAL OF INFECTION AND CHEMOTHERAPY, 2022, 28 (02) :248-251
[2]   The development of an electrochemical immunosensor utilizing chicken IgY anti-spike antibody for the detection of SARS-CoV-2 [J].
Al-Qaoud, Khaled M. ;
Obeidat, Yusra M. ;
Al-Omari, Tareq ;
Okour, Mohammad ;
Al-Omari, Mariam M. ;
Ahmad, Mohammad I. ;
Alshadfan, Raed ;
Rawashdeh, AbdelMonem M. .
SCIENTIFIC REPORTS, 2024, 14 (01)
[3]   Water Sorption in MXene/Polyelectrolyte Multilayers for Ultrafast Humidity Sensing [J].
An, Hyosung ;
Habib, Touseef ;
Shah, Smit ;
Gao, Huili ;
Patel, Anish ;
Echols, Ian ;
Zhao, Xiaofei ;
Radovic, Miladin ;
Green, Micah J. ;
Lutkenhaus, Jodie L. .
ACS APPLIED NANO MATERIALS, 2019, 2 (02) :948-955
[4]   Comparison of COVID-19 laboratory diagnosis by commercial kits: Effectivity of RT-PCR to the RT-LAMP [J].
Artik, Yakup ;
Cosgun, Alp B. ;
Cesur, Nevra P. ;
Hizel, Nedret ;
Uyar, Yavuz ;
Sur, Haydar ;
Ayan, Alp .
JOURNAL OF MEDICAL VIROLOGY, 2022, 94 (05) :1998-2007
[5]   Electrochemical immunosensors using electrodeposited gold nanostructures for detecting the S proteins from SARS-CoV and SARS-CoV-2 [J].
Brazaca, Lais Canniatti ;
Imamura, Amanda Hikari ;
Gomes, Nathalia Oezau ;
Almeida, Mariana Bortholazzi ;
Scheidt, Desiree Tamara ;
Raymundo-Pereira, Paulo A. ;
Oliveira Jr, Osvaldo N. ;
Janegitz, Bruno Campos ;
Spinola Machado, Sergio Antonio ;
Carrilho, Emanuel .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (18) :5507-5517
[6]   An impedimetric approach for COVID-19 detection [J].
Buyuksunetci, Yudum Tepeli ;
Citil, Burak Ekrem ;
Anik, Ulku .
ANALYST, 2021, 147 (01) :130-138
[7]   Enhanced thermal properties of poly(vinylidene fluoride) composites with ultrathin nanosheets of MXene [J].
Cao, Yong ;
Deng, Qihuang ;
Liu, Zhiduo ;
Shen, Dianyu ;
Wang, Ting ;
Huang, Qing ;
Du, Shiyu ;
Jiang, Nan ;
Lin, Cheng-Te ;
Yu, Jinhong .
RSC ADVANCES, 2017, 7 (33) :20494-20501
[8]   Emergence of MXene-Polymer Hybrid Nanocomposites as High-Performance Next-Generation Chemiresistors for Efficient Air Quality Monitoring [J].
Chaudhary, Vishal ;
Ashraf, Naveed ;
Khalid, Mohammad ;
Walvekar, Rashmi ;
Yang, Ya ;
Kaushik, Ajeet ;
Mishra, Yogendra Kumar .
ADVANCED FUNCTIONAL MATERIALS, 2022, 32 (33)
[9]   Sensitive electrochemical immunoassay of metallothionein-3 based on K3[Fe(CN)6] as a redox-active signal and C-dots/Nafion film for antibody immobilization [J].
Chen, Min ;
Zhao, Chengfei ;
Chen, Wei ;
Weng, Shaohuang ;
Liu, Ailin ;
Liu, Qicai ;
Zheng, Zongfu ;
Lin, Jianhua ;
Lin, Xinhua .
ANALYST, 2013, 138 (24) :7341-7346
[10]   Electrochemical sensing platform based on tris(2,2′-bipyridyl)cobalt(III) and multiwall carbon nanotubes-Nafion composite for immunoassay of carcinoma antigen-125 [J].
Chen, Shihong ;
Yuan, Ruo ;
Chai, Yaqin ;
Min, Ligen ;
Li, Wenjuan ;
Xu, Yang .
ELECTROCHIMICA ACTA, 2009, 54 (28) :7242-7247