Study of V2CT x -MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein

被引:2
作者
Tasic, Nikola [1 ]
Konjevic, Ivan [1 ,2 ]
Lobato, Alnilan [1 ,3 ]
Metarapi, Dino [1 ]
Finsgar, Matjaz [4 ]
Oliveira, Filipa M. [5 ]
Sofer, Zdenek [5 ]
Gusmao, Rui [5 ]
Zhang, Xueji [6 ]
Hocevar, Samo B. [1 ]
机构
[1] Natl Inst Chem, Dept Analyt Chem, Ljubljana 1000, Slovenia
[2] Univ Ljubljana, Fac Chem & Chem Technol, Ljubljana 1000, Slovenia
[3] Int Postgrad Sch Jozef Stefan, Ljubljana 1000, Slovenia
[4] Univ Maribor, Fac Chem & Chem Engn, Maribor 2000, Slovenia
[5] Univ Chem & Technol Prague, Dept Inorgan Chem, 6 Dejvice, Prague 16628, Czech Republic
[6] Shenzhen Univ Hlth Sci Ctr, Sch Biomed Engn, Shenzhen 518054, Guangdong, Peoples R China
关键词
V2CT x MXene; SARS-CoV-2; spike protein; immunosensor; electrochemical; impedimetric; NAFION; GLUTARALDEHYDE; COMPOSITE; IMMUNOASSAY;
D O I
10.1021/acsami.4c04567
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.
引用
收藏
页码:30196 / 30208
页数:13
相关论文
共 61 条
  • [1] Evaluation and clinical implications of the time to a positive results of antigen testing for SARS-CoV-2
    Akashi, Yusaku
    Kiyasu, Yoshihiko
    Takeuchi, Yuto
    Kato, Daisuke
    Kuwahara, Miwa
    Muramatsu, Shino
    Ueda, Atsuo
    Notake, Shigeyuki
    Nakamura, Koji
    Ishikawa, Hiroichi
    Suzuki, Hiromichi
    [J]. JOURNAL OF INFECTION AND CHEMOTHERAPY, 2022, 28 (02) : 248 - 251
  • [2] The development of an electrochemical immunosensor utilizing chicken IgY anti-spike antibody for the detection of SARS-CoV-2
    Al-Qaoud, Khaled M.
    Obeidat, Yusra M.
    Al-Omari, Tareq
    Okour, Mohammad
    Al-Omari, Mariam M.
    Ahmad, Mohammad I.
    Alshadfan, Raed
    Rawashdeh, AbdelMonem M.
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01)
  • [3] Water Sorption in MXene/Polyelectrolyte Multilayers for Ultrafast Humidity Sensing
    An, Hyosung
    Habib, Touseef
    Shah, Smit
    Gao, Huili
    Patel, Anish
    Echols, Ian
    Zhao, Xiaofei
    Radovic, Miladin
    Green, Micah J.
    Lutkenhaus, Jodie L.
    [J]. ACS APPLIED NANO MATERIALS, 2019, 2 (02) : 948 - 955
  • [4] Comparison of COVID-19 laboratory diagnosis by commercial kits: Effectivity of RT-PCR to the RT-LAMP
    Artik, Yakup
    Cosgun, Alp B.
    Cesur, Nevra P.
    Hizel, Nedret
    Uyar, Yavuz
    Sur, Haydar
    Ayan, Alp
    [J]. JOURNAL OF MEDICAL VIROLOGY, 2022, 94 (05) : 1998 - 2007
  • [5] Electrochemical immunosensors using electrodeposited gold nanostructures for detecting the S proteins from SARS-CoV and SARS-CoV-2
    Brazaca, Lais Canniatti
    Imamura, Amanda Hikari
    Gomes, Nathalia Oezau
    Almeida, Mariana Bortholazzi
    Scheidt, Desiree Tamara
    Raymundo-Pereira, Paulo A.
    Oliveira Jr, Osvaldo N.
    Janegitz, Bruno Campos
    Spinola Machado, Sergio Antonio
    Carrilho, Emanuel
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (18) : 5507 - 5517
  • [6] An impedimetric approach for COVID-19 detection
    Buyuksunetci, Yudum Tepeli
    Citil, Burak Ekrem
    Anik, Ulku
    [J]. ANALYST, 2021, 147 (01) : 130 - 138
  • [7] Enhanced thermal properties of poly(vinylidene fluoride) composites with ultrathin nanosheets of MXene
    Cao, Yong
    Deng, Qihuang
    Liu, Zhiduo
    Shen, Dianyu
    Wang, Ting
    Huang, Qing
    Du, Shiyu
    Jiang, Nan
    Lin, Cheng-Te
    Yu, Jinhong
    [J]. RSC ADVANCES, 2017, 7 (33): : 20494 - 20501
  • [8] Emergence of MXene-Polymer Hybrid Nanocomposites as High-Performance Next-Generation Chemiresistors for Efficient Air Quality Monitoring
    Chaudhary, Vishal
    Ashraf, Naveed
    Khalid, Mohammad
    Walvekar, Rashmi
    Yang, Ya
    Kaushik, Ajeet
    Mishra, Yogendra Kumar
    [J]. ADVANCED FUNCTIONAL MATERIALS, 2022, 32 (33)
  • [9] Sensitive electrochemical immunoassay of metallothionein-3 based on K3[Fe(CN)6] as a redox-active signal and C-dots/Nafion film for antibody immobilization
    Chen, Min
    Zhao, Chengfei
    Chen, Wei
    Weng, Shaohuang
    Liu, Ailin
    Liu, Qicai
    Zheng, Zongfu
    Lin, Jianhua
    Lin, Xinhua
    [J]. ANALYST, 2013, 138 (24) : 7341 - 7346
  • [10] Electrochemical sensing platform based on tris(2,2′-bipyridyl)cobalt(III) and multiwall carbon nanotubes-Nafion composite for immunoassay of carcinoma antigen-125
    Chen, Shihong
    Yuan, Ruo
    Chai, Yaqin
    Min, Ligen
    Li, Wenjuan
    Xu, Yang
    [J]. ELECTROCHIMICA ACTA, 2009, 54 (28) : 7242 - 7247