Fatigue performance of composite-steel injected connectors at room and elevated temperatures

被引:0
作者
Christoforidou, Angeliki [1 ]
Pavlovic, Marko [1 ]
机构
[1] Delft Univ Technol, Steel & Composite Struct, Delft, Netherlands
关键词
Prefabricated construction; Prefabricated bolted connector; Steel structures; Fibre reinforced polymers (FRP); Composite decks; Thermal -mechanical properties; Fatigue; Shear resistance; BOLTED SHEAR CONNECTORS; BEHAVIOR; CONCRETE; JOINTS; BEAMS;
D O I
10.1016/j.engstruct.2024.118421
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The integration of Glass Fibre-Polymer composite (a.k.a. GFRP) deck panels in bridge infrastructure is hindered by lacking a robust connection technology. A promising bolted connection, utilising injected steel reinforced resin (iSRR) material, has demonstrated lower creep deformation and sustained significantly more shear load cycles than conventional bolts. Nonetheless, the production and testing conditions in all prior experimental campaigns followed idealized lab set-ups. This study bridges the gap between laboratory conditions and the challenges arising during connector's fabrication under representative conditions, coupled with cyclic load testing at room and elevated temperatures. The iSRR connectors design is modified and tested in actual composite sandwich web core panels, revealing excellent fatigue performance. The statistical analysis yielded F-N curves for shear performance of the connectors that can be used in the design. The slopes of the F-N curves of 6.6 and - 5.8 were found at room and elevated temperatures, respectively. Finally, with post-cyclic static tests displaying significant connectors' residual stiffness, resistance, and ductility, the research provides a step forward in enabling the integration of glass fibre composite deck in infrastructure.
引用
收藏
页数:16
相关论文
共 40 条
[31]  
Sams M, 2005, Transportation Research Record: Journal of the Transportation Research Board
[32]   FATIGUE OF BOLTED JOINTS IN (0/90) CFRP LAMINATES [J].
SMITH, PA ;
PASCOE, KJ .
COMPOSITES SCIENCE AND TECHNOLOGY, 1987, 29 (01) :45-69
[33]  
Snijder H., 2017, IABSE S REP
[34]   Failure of pultruded GRP single-bolt tension joints under hot-wet conditions [J].
Turvey, G. J. ;
Wang, P. .
COMPOSITE STRUCTURES, 2007, 77 (04) :514-520
[35]   Fatigue behaviour of bolted connections in pultruded FRP profiles [J].
van Wingerde, AM ;
van Delft, DRV ;
Knudsen, ES .
PLASTICS RUBBER AND COMPOSITES, 2003, 32 (02) :71-76
[36]  
Vassilopoulos AP, 2011, ENG MATER PROCESS, P1, DOI 10.1007/978-1-84996-181-3
[37]   Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures [J].
Wang, Jun-Yan ;
Guo, Jun-Yuan ;
Jia, Liang-Jiu ;
Chen, Shi-Ming ;
Dong, Yang .
COMPOSITE STRUCTURES, 2017, 170 :69-79
[38]   Effect of Elevated Temperatures on the Mechanical Performance of Pultruded FRP Joints with a Single Ordinary or Blind Bolt [J].
Wu, Chao ;
Bai, Yu ;
Mottram, J. Toby .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (02)
[39]   Experimental and numerical study on tensile properties of bolted GFRP joints at high and low temperatures [J].
Xue, Congcong ;
Yu, Min ;
Yang, Biying ;
Wang, Tan ;
Saafi, Mohamed ;
Ye, Jianqiao .
COMPOSITE STRUCTURES, 2022, 293
[40]   Experimental and numerical analyses on the shear behavior of grouped single-embedded-nut high-strength bolts in steel-ultra-high-performance concrete composite slabs [J].
Zhang, Yujie ;
Zhu, Jianhui ;
Wu, Linlang ;
Lin, Hanxu ;
Fang, Zhuangcheng ;
Cen, Zicong ;
Yang, Yongmin ;
Fang, Shu .
JOURNAL OF BUILDING ENGINEERING, 2024, 86