Comparison of Elva Diagnostic SARS-CoV-2 Saliva Nucleic Acid Test Kit with RT-qPCR and Rapid Antigen Tests in COVID-19 Patients

被引:0
作者
Allositandi, Yudi Agustinus [1 ]
Kahar, Hartono [2 ]
Aulia, Fauqa Arinil [2 ]
机构
[1] Univ Airlangga, Dr Soetomo Hosp, Fac Med, Clin Microbiol Specialist Program, Surabaya, Indonesia
[2] Airlangga Univ, Dr Soetomo Hosp, Fac Med, Dept Clin Pathol, Surabaya, Indonesia
关键词
COVID-19; RT-qPCR; RT-LAMP; Rapid Antigen Test; Sensitivity; Specificity; LAMP;
D O I
10.22207/JPAM.18.2.06
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The practical application of the reverse transcription loop -mediated isothermal amplification (RT-LAMP) technique has been confirmed in diagnosing different viral infections. Nevertheless, its accuracy in identifying SARS-CoV-2, particularly in practical clinical situations, has not been thoroughly investigated. This study aims to investigate the sensitivity and specificity of the Elva Diagnostic SARS-CoV-2 Saliva Nucleic Acid Test Kit, utilizing the RT-LAMP and Rapid Antigen Test (RAT) methods for in vitro diagnostic testing, compared to the real-time quantitative polymerase chain reaction (RT-qPCR) method throughout the progression of COVID-19. Method: This study employed an analytical observational diagnostic test at Dr. Soetomo Regional Public Hospital, Surabaya, from March 2022 to May 2022. This research involved 54 samples of saliva and nasopharyngeal swabs obtained from 36 patients confirmed positive for COVID-19 and 18 samples from subjects not confirmed to have COVID-19, tested using the RT-qPCR method. The diagnostic performance of both the RT-LAMP and RAT methods was assessed by calculating their sensitivity and specificity in comparison to RT-qPCR, beginning from the time the patient was confirmed positive for COVID-19. The suitability of each method was analyzed using Cohen's kappa. The nucleocapsid (N) protein gene from SARS-CoV-2 RNA was detected with RT-LAMP and RAT test kits which showed incompatibilities with the RT-qPCR method (p value 0.308). The positive and negative results with the RT-LAMP and RAT method examinations were similar in number compared to the RT-qPCR method, where the positive results in the RT-LAMP and RAT methods were 2 subjects and the negative results were 52 subjects. Based on the results, only 2 confirmed cases had positive results with RT-LAMP and RAT, which means the sensitivity of both tests is only 5.5% and both are poor screening tests for patients suspected of having COVID-19. In addition, the specificity of RT-qPCR as the gold standard examination method for diagnosing COVID-19 cannot be replaced by the RT-LAMP and RAT methods.
引用
收藏
页码:929 / 940
页数:12
相关论文
共 27 条
[1]  
Ansori Arif Nur Muhammad, 2021, Research Journal of Pharmacy and Technology, V14, P5551, DOI 10.52711/0974-360X.2021.00967
[2]   Clinical characteristics and mortality associated with COVID-19 in islamic hospital of Jemursari, Surabaya, Indonesia: A hospital-based retrospective cohort study [J].
Awwaliyah, Evi ;
Hotimah ;
Shimabukuro, Michio .
BALI MEDICAL JOURNAL, 2022, 11 (03) :1202-1206
[3]   An Animal Model of Inhaled Vitamin E Acetate and EVALI-like Lung Injury [J].
Bhat, Tariq A. ;
Goniewicz, Maciej L. ;
Thanavala, Yasmin M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2020, 382 (12) :1175-1177
[4]   Rapid SARS-CoV-2 antigen detection assay in comparison with real-time RT-PCR assay for laboratory diagnosis of COVID-19 in Thailand [J].
Chaimayo, Chutikarn ;
Kaewnaphan, Bualan ;
Tanlieng, Nattaya ;
Athipanyasilp, Niracha ;
Sirijatuphat, Rujipas ;
Chayakulkeeree, Methee ;
Angkasekwinai, Nasikarn ;
Sutthent, Ruengpung ;
Puangpunngam, Nattawut ;
Tharmviboonsri, Theerawoot ;
Pongraweewan, Orawan ;
Chuthapisith, Suebwong ;
Sirivatanauksorn, Yongyut ;
Kantakamalakul, Wannee ;
Horthongkham, Navin .
VIROLOGY JOURNAL, 2020, 17 (01)
[5]   Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR (Publication with Expression of Concern) [J].
Corman, Victor M. ;
Landt, Olfert ;
Kaiser, Marco ;
Molenkamp, Richard ;
Meijer, Adam ;
Chu, Daniel K. W. ;
Bleicker, Tobias ;
Bruenink, Sebastian ;
Schneider, Julia ;
Schmidt, Marie Luisa ;
Mulders, Daphne G. J. C. ;
Haagmans, Bart L. ;
van der Veer, Bas ;
van den Brink, Sharon ;
Wijsman, Lisa ;
Goderski, Gabriel ;
Romette, Jean-Louis ;
Ellis, Joanna ;
Zambon, Maria ;
Peiris, Malik ;
Goossens, Herman ;
Reusken, Chantal ;
Koopmans, Marion P. G. ;
Drosten, Christian .
EUROSURVEILLANCE, 2020, 25 (03) :23-30
[6]   Retrieval and Investigation of Data on SARS-CoV-2 and COVID-19 Using Bioinformatics Approach [J].
Fahmi, Muhamad ;
Kharisma, Viol Dhea ;
Ansori, Arif Nur Muhammad ;
Ito, Masahiro .
CORONAVIRUS DISEASE - COVID-19, 2021, 1318 :839-857
[7]   Low clinical performance of the Isopollo COVID-19 detection kit (M Monitor, South Korea) for RT-LAMP SARS-CoV-2 diagnosis: A call for action against low quality products for developing countries [J].
Freire-Paspuel, Byron ;
Garcia-Bereguiain, Miguel Angel .
INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2021, 104 :303-305
[8]  
Ganguli A, 2020, bioRxiv, DOI [10.1073/pnas.2014739117, 10.1101/2020.05.21.108381]
[9]   Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China [J].
Huang, Chaolin ;
Wang, Yeming ;
Li, Xingwang ;
Ren, Lili ;
Zhao, Jianping ;
Hu, Yi ;
Zhang, Li ;
Fan, Guohui ;
Xu, Jiuyang ;
Gu, Xiaoying ;
Cheng, Zhenshun ;
Yu, Ting ;
Xia, Jiaan ;
Wei, Yuan ;
Wu, Wenjuan ;
Xie, Xuelei ;
Yin, Wen ;
Li, Hui ;
Liu, Min ;
Xiao, Yan ;
Gao, Hong ;
Guo, Li ;
Xie, Jungang ;
Wang, Guangfa ;
Jiang, Rongmeng ;
Gao, Zhancheng ;
Jin, Qi ;
Wang, Jianwei ;
Cao, Bin .
LANCET, 2020, 395 (10223) :497-506
[10]   Diagnostic accuracy of LAMP versus PCR over the course of SARS-CoV-2 infection [J].
Inaba, Masato ;
Higashimoto, Yuki ;
Toyama, Yoko ;
Horiguchi, Tomoya ;
Hibino, Masaya ;
Iwata, Mitsunaga ;
Imaizumi, Kazuyoshi ;
Doi, Yohei .
INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2021, 107 :195-200