Comparative numerical study of floor heating systems using parallel and spiral coil

被引:2
作者
Anigrou, Yassine [1 ]
Zouini, Mohammed [2 ]
机构
[1] Hassan II Univ Casablanca, Fac Sci & Tech Mohammedia, Casablanca 28806, Morocco
[2] Sidi Mohamed Ben Abdellah Univ, Lab Comp Sci & Interdisciplinary Phys, ENS, Fes, Morocco
关键词
Underfloor heating; Traditional hammam; CFD simulation; Serpentine; Spiral pose; Parallel pose; Heating floor; TRADITIONAL HAMMAMS; HERITAGE BUILDINGS; TECHNOLOGIES; PERFORMANCE; WASTE;
D O I
10.1016/j.sciaf.2024.e02188
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This article presents a comparative numerical study aimed at determining the optimal pipe layout solution for the heating benches of traditional steam baths, with the goal of ensuring an optimal temperature distribution for customer comfort. This layout incorporates insulation on the lower side to direct most of the emitted heat upwards. The temperature distribution across the floor surface varies depending on the configuration of the buried pipes. Calculations were performed using the CFD software "COMSOL Multiphysics" to investigate the thermal behavior of an underfloor heating system. The results were used to discuss certain critical parameters that require control for the proper operation of the system. These parameters include the flow velocity inside the pipes, inlet temperatures, and pipe configuration. A new parameter designed to measure the thermal homogeneity of the floor was introduced and evaluated. In general, the findings demonstrated that the modulated spiral configuration is the best solution, minimizing pressure losses while ensuring optimal thermal homogenization across the entire floor surface.
引用
收藏
页数:13
相关论文
共 37 条
[11]  
GNIELINSKI V, 1976, INT CHEM ENG, V16, P359
[12]   A combined low temperature water heating system consisting of radiators and floor heating [J].
Hasan, Ala ;
Kurnitski, Jarek ;
Jokiranta, Kai .
ENERGY AND BUILDINGS, 2009, 41 (05) :470-479
[13]   Numerical simulation of radiant floor cooling system: The effects of thermal resistance of pipe and water velocity on the performance [J].
Jin, Xing ;
Zhang, Xiaosong ;
Luo, Yajun ;
Cao, Rongquan .
BUILDING AND ENVIRONMENT, 2010, 45 (11) :2545-2552
[14]   Simulation of floor heating in a combined solar-biomass system integrated in a public bathhouse located in Marrakech [J].
Krarouch, M. ;
Hamdi, H. ;
Lamghari, S. ;
Outzourhit, A. .
SUSTAINABLE BUILDINGS AND CITIES, 2017, 2018, 353
[15]   Dynamic simulation and economic analysis of a combined solar thermal and pellet heating system for domestic hot water production in a traditional Hammam [J].
Krarouch, Mohamed ;
Ruesch, Florian ;
Hamdi, Hassan ;
Outzourhit, Abdelkader ;
Haller, Michel .
APPLIED THERMAL ENGINEERING, 2020, 180
[16]   Evaluation and comparison of thermal comfort of convective and radiant heating terminals in office buildings [J].
Lin, Borong ;
Wang, Zhe ;
Sun, Hongli ;
Zhu, Yingxin ;
Ouyang, Qin .
BUILDING AND ENVIRONMENT, 2016, 106 :91-102
[17]  
Lurie M.V., 2008, Modeling of Oil Product and Gas Pipeline Transportation, P230
[18]   The multistep Laplace optimized decomposition method for solving fractional-order coronavirus disease model (COVID-19) via the Caputo fractional approach [J].
Maayah, Banan ;
Moussaoui, Asma ;
Bushnaq, Samia ;
Abu Arqub, Omar .
DEMONSTRATIO MATHEMATICA, 2022, 55 (01) :963-977
[19]  
Meir Y.B., 2022, ENV CHALL, V6
[20]   Physico-Chemical Characterization of an Urban Wastewater Effluent and its Impact on the Receiving Environment: Oued Nfifikh (Morocco) [J].
Merbouh, Chaimaa ;
Namoussi, Soukaina ;
Kabriti, Mohamed ;
Naamane, Ayoub ;
Rihane, Abdeslam ;
Iounes, Nadia .
JOURNAL OF ECOLOGICAL ENGINEERING, 2022, 23 (03) :183-193