An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids

被引:11
作者
Yang, Yong [1 ]
Sheng, Can [1 ]
Dong, Fang [2 ]
Liu, Sheng [1 ,2 ,3 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, Wuhan 430074, Peoples R China
[2] Wuhan Univ, Inst Technol Sci, Wuhan 430072, Peoples R China
[3] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Peoples R China
[4] Wuhan Univ, Sch Microelect, Wuhan 430072, Peoples R China
关键词
Interstitial fluid; Microneedles; Continuous glucose monitoring; Wearable sensors; INSERTION;
D O I
10.1016/j.bios.2024.116280
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Monitoring biomarkers in human interstitial fluids (ISF) using microneedle sensors has been extensively studied. However, most of the previous studies were limited to simple in vitro demonstrations and lacked system integration and analytical performance. Here we report a miniaturized, high-precision, fully integrated wearable electrochemical microneedle sensing device that works with a customized smartphone application to wirelessly and in real-time monitor glucose in human ISF. A microneedle array fabrication method is proposed which enables multiple individually addressable, regionally separated sensing electrodes on a single microneedle system. As a demonstration, a glucose sensor and a differential sensor are integrated in a single sensing patch. The differential sensing electrodes can eliminate common-mode interference signals, thus significantly improving the detection accuracy. The basic mechanism of microneedle penetration into the skin was analyzed using the finite element method (FEM). By optimizing the structure of the microneedle, the puncture efficiency was improved while the puncture force was reduced. The electrochemical properties, biocompatibility, and system stability of the microneedle sensing device were characterized before human application. The test results were closely correlated with the gold standard (blood). The platform can be used not only for glucose detection, but also for various ISF biomarkers, and it expands the potential of microneedle technology in wearable sensing.
引用
收藏
页数:9
相关论文
共 45 条
[1]  
[Anonymous], 2020, TOP 10 EMERGING TECH
[2]   A hybridized nano-porous carbon reinforced 3D graphene-based epidermal patch for precise sweat glucose and lactate analysis [J].
Asaduzzaman, Md ;
Abu Zahed, Md ;
Sharifuzzaman, Md ;
Reza, Md Selim ;
Hui, Xue ;
Sharma, Sudeep ;
Do Shin, Young ;
Park, Jae Yeong .
BIOSENSORS & BIOELECTRONICS, 2023, 219
[3]   Resettable Microfluidics for Broad-Range and Prolonged Sweat Rate Sensing [J].
Bariya, Mallika ;
Davis, Noelle ;
Gillan, Liam ;
Jansson, Elina ;
Kokkonen, Annukka ;
McCaffrey, Colm ;
Hiltunen, Jussi ;
Javey, Ali .
ACS SENSORS, 2022, 7 (04) :1156-1164
[4]   Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms [J].
Brothers, Michael C. ;
DeBrosse, Madeleine ;
Grigsby, Claude C. ;
Naik, Rajesh R. ;
Hussain, Saber M. ;
Heikenfeld, Jason ;
Kim, Steve S. .
ACCOUNTS OF CHEMICAL RESEARCH, 2019, 52 (02) :297-306
[5]   Air-permeable electrode for highly sensitive and noninvasive glucose monitoring enabled by graphene fiber fabrics [J].
Cai, Shengying ;
Xu, Changshun ;
Jiang, Danfeng ;
Yuan, Meiling ;
Zhang, Qingwen ;
Li, Zhaoling ;
Wang, Yi .
NANO ENERGY, 2022, 93
[6]   Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring [J].
Chen, Yihao ;
Lu, Siyuan ;
Zhang, Shasha ;
Li, Yan ;
Qu, Zhe ;
Chen, Ying ;
Lu, Bingwei ;
Wang, Xinyan ;
Feng, Xue .
SCIENCE ADVANCES, 2017, 3 (12)
[7]   A touch-actuated glucose sensor fully integrated with microneedle array and reverse iontophoresis for diabetes monitoring [J].
Cheng, Yanxiang ;
Gong, Xia ;
Yang, Jian ;
Zheng, Guizhou ;
Zheng, Ying ;
Li, Yanjun ;
Xu, Yunsheng ;
Nie, Gang ;
Xie, Xi ;
Chen, Meiwan ;
Yi, Changqing ;
Jiang, Lelun .
BIOSENSORS & BIOELECTRONICS, 2022, 203
[8]   Template-free growth of regular nano-structured Prussian blue on a platinum surface and its application in biosensors with high sensitivity [J].
Chu, Zhenyu ;
Zhang, Yannan ;
Dong, Xueliang ;
Jin, Wanqin ;
Xu, Nanping ;
Tieke, Bernd .
JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (36) :7815-7820
[9]   Silicon Micropillar Array-Based Wearable Sweat Glucose Sensor [J].
Dervisevic, Muamer ;
Alba, Maria ;
Esser, Lars ;
Tabassum, Nazia ;
Prieto-Simon, Beatriz ;
Voelcker, Nicolas H. .
ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (01) :2401-2410
[10]   Transdermal Electrochemical Monitoring of Glucose via High-Density Silicon Microneedle Array Patch [J].
Dervisevic, Muamer ;
Alba, Maria ;
Yan, Li ;
Senel, Mehmet ;
Gengenbach, Thomas R. ;
Prieto-Simon, Beatriz ;
Voelcker, Nicolas H. .
ADVANCED FUNCTIONAL MATERIALS, 2022, 32 (03)