Primary stability and osseointegration comparing a novel tapered design tissue-level implant with a parallel design tissue-level implant. An experimental in vivo study

被引:3
作者
Gill, Thomas [1 ]
Kuhl, Sebastian [2 ]
Rawlinson, Simon [1 ]
Pippenger, Benjamin [3 ,4 ]
Bellon, Benjamin [4 ,5 ]
Shahdad, Shakeel [1 ,6 ,7 ]
机构
[1] Queen Mary Univ London, Inst Dent, Barts & London Sch Med & Dent, London, England
[2] Univ Basel, Univ Ctr Dent Med, Dept Oral Surg, Basel, Switzerland
[3] Univ Bern, Sch Dent Med, Dept Periodontol, Bern, Switzerland
[4] Inst Straumann AG, Dept Preclin Res, Basel, Switzerland
[5] Univ Tampere, Fac Med & Hlth Technol, Tampere, Finland
[6] Royal London Dent Hosp, Dept Restorat Dent, Barts Hlth NHS Trust, London, England
[7] Royal London Dent Hosp, Dept Restorat Dent, Turner St, London E1 1DE, England
关键词
implant crestal bone formation; implant geometry; implant surface; osseointegration; tapered; tissue-level; RESONANCE FREQUENCY-ANALYSIS; CRESTAL BONE CHANGES; CHEMICALLY-MODIFIED SLACTIVE((R)); PARTIALLY EDENTULOUS PATIENTS; IMMEDIATELY PLACED IMPLANTS; DEHISCENCE-TYPE DEFECTS; SLA TITANIUM IMPLANTS; DENTAL IMPLANTS; INSERTION TORQUE; RADIOGRAPHIC EVALUATION;
D O I
10.1111/clr.14301
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of the present study was to compare a novel tapered, double-threaded self-tapping tissue-Level design implant (TLC) to a well-established parallel walled tissue-level (TL) implant in terms of primary and secondary stability over time. Materials and Methods: Test TLC (n = 10/per timepoint) and control TL (n = 10/per timepoint) implants were placed in the mandible of minipigs and left for submerged healing for 3, 6, and 12 weeks. Maximum insertion torque and implant stability quotient (ISQ) were measured for each implant at placement. Osseointegration and cortical bone maintenance were histologically evaluated by measuring total bone-to-implant contact (BIC) and first bone-to-implant contact (fBIC). Results: A significantly higher maximum insertion torque was measured for the test implant TLC compared to the control TL implant (57.83 +/- 24.73 Ncm and 22.62 +/- 23.16 Ncm, respectively; p < .001). The mean ISQ values were comparable between the two implant types (75.00 +/- 6.70 for TL compared to 75.40 +/- 3.20 for TLC, p = .988). BIC was comparable between both implant types at each of the evaluated time points. The fBIC was found to be significantly more coronal at 12 weeks for the TLC implant compared to the TL implant (0.31 +/- 0.83 mm for TLC compared to -0.22 +/- 0.85 for TL, p = .027). Conclusion: The novel tapered tissue level design implant showed improved primary stability and an overall improved crestal bone height maintenance compared to the parallel walled design at 12 weeks.
引用
收藏
页码:1114 / 1127
页数:14
相关论文
共 78 条
  • [1] Effects of different implant surfaces and designs on marginal bone-level alterations: a review
    Abrahamsson, Ingemar
    Berglundh, Tord
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 : 207 - 215
  • [2] Implant design and intraosseous stability of immediately placed implants: a human cadaver study
    Akkocaoglu, M
    Uysal, S
    Tekdemir, I
    Akca, K
    Cehreli, MC
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) : 202 - 209
  • [3] Alves CC, 2009, INT J PERIODONT REST, V29, P161
  • [4] Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis
    Atieh, Momen A.
    Alsabeeha, Nabeel
    Duncan, Warwick J.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) : 634 - 645
  • [5] Evaluation of Optimal Taper of Immediately Loaded Wide-Diameter Implants: A Finite Element Analysis
    Atieh, Momen A.
    Shahmiri, Reza A.
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (02) : 123 - 132
  • [6] Platform Switching for Marginal Bone Preservation Around Dental implants: A Systematic Review and Meta-Analysis
    Atieh, Momen A.
    Ibrahim, Hadeel M.
    Atieh, Ahmad H.
    [J]. JOURNAL OF PERIODONTOLOGY, 2010, 81 (10) : 1350 - 1366
  • [7] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [8] Implant Compression Necrosis: Current Understanding and Case Report
    Bashutski, Jill D.
    D'Silva, Nisha J.
    Wang, Hom-Lay
    [J]. JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) : 700 - 704
  • [9] Bone apposition around two different sandblasted and acid-etched titanium implant surfaces: a histomorphometric study in canine mandibles
    Bornstein, Michael M.
    Valderrama, Pilar
    Jones, Archie A.
    Wilson, Thomas G.
    Seibl, Reinhart
    Cochran, David L.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) : 233 - 241
  • [10] Enhanced bone apposition to a chemically modified SLA titanium surface
    Buser, D
    Broggini, N
    Wieland, M
    Schenk, RK
    Denzer, AJ
    Cochran, DL
    Hoffmann, B
    Lussi, A
    Steinemann, SG
    [J]. JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) : 529 - 533