Satisfaction with home blood sampling methods and expectations for future point-of-care testing in phenylketonuria: Perspectives from patients and professionals

被引:2
作者
Kuypers, Allysa M. [1 ]
Evers-van Vliet, Kimber [1 ]
Macdonald, Anita [3 ]
Ahring, Kirsten [4 ]
Abeln, David [5 ]
Ford, Suzanne [6 ]
Hildebrandt-Karlsen, Sanne [7 ]
van Spronsen, Francjan J. [1 ]
Heiner-Fokkema, M. Rebecca [2 ,8 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Beatrix Childrens Hosp, Sect Metab Dis, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Lab Med, Lab Metab Dis, Groningen, Netherlands
[3] Birmingham Womens & Childrens Hosp NHS Fdn Trust, Steelhouse Lane, Birmingham B4 6NH, England
[4] Kennedy Ctr, Dept PKU, Glostrup, Denmark
[5] Dutch PKU Assoc, Tiel, Netherlands
[6] Natl Soc Phenylketonuria NSPKU, Richard House, Sheffield, Lancs, England
[7] Danish PKU Assoc, Tiel, Denmark
[8] Univ Groningen, Univ Med Ctr Groningen, Lab Metab Dis, Dept Lab Med, POB 30 001, NL-9700 RB Groningen, Netherlands
关键词
Phenylalanine (Phe); Phenylketonuria (PKU); Home sampling; Dried blood spots (DBS); Home monitoring; Point-of-care testing (POCT); PHENYLALANINE; QUALITY; RECOMMENDATIONS; FREQUENCY;
D O I
10.1016/j.ymgme.2024.108361
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Phenylketonuria (PKU) requires regular phenylalanine monitoring to ensure optimal outcome. However, home sampling methods used for monitoring suffer high pre-analytical variability, inter-laboratory variability and turn-around-times, highlighting the need for alternative methods of home sampling or monitoring. Methods: A survey was distributed through email and social media to (parents of) PKU patients and professionals working in inherited metabolic diseases in Denmark, The Netherlands, and United Kingdom regarding satisfaction with current home sampling methods and expectations for future point-of-care testing (POCT). Results: 210 parents, 156 patients and 95 professionals completed the survey. Countries, and parents and patients were analysed together, in absence of significant group differences for most questions. Important results are: 1) Many patients take less home samples than advised. 2) The majority of (parents of) PKU patients are (somewhat) dissatisfied with their home sampling method, especially with turn-around-times (3 -5 days). 3) 37% of professionals are dissatisfied with their home sampling method and 45% with the turn-aroundtimes. 4) All responders are positive towards developments for POCT: 97% ( n = 332) of (parents of) patients is willing to use a POC-device and 76% ( n = 61) of professionals would recommend their patients to use a POCdevice. 5) Concerns from all participants for future POC-devices are costs/reimbursements and accuracy, and to professionals specifically, accessibility to results, over -testing, patient anxiety, and patients adjusting their diet without consultation. Conclusion: The PKU community is (somewhat) dissatisfied with current home sampling methods, highlighting the need for alternatives of Phe monitoring. POCT might be such an alternative and the community is eager for its arrival.
引用
收藏
页数:11
相关论文
共 44 条
[1]   Plasma phenylalanine in patients with phenylketonuria self-managing their diet [J].
Bekhof, J ;
van Rijn, M ;
Sauer, PJJ ;
Ten Vergert, EM ;
Reijngoud, DJ ;
van Spronsen, FJ .
ARCHIVES OF DISEASE IN CHILDHOOD, 2005, 90 (02) :163-164
[2]   Dried blood spot collection, sample quality, and fieldwork conditions: Structural validations for conversion into standard values [J].
Boersch-Supan, Axel ;
Weiss, Luzia M. ;
Boersch-Supan, Martina ;
Potter, Alan J. ;
Cofferen, Jake ;
Kerschner, Elizabeth .
AMERICAN JOURNAL OF HUMAN BIOLOGY, 2021, 33 (04)
[3]   Effectiveness of point-of-care testing for therapeutic control of chronic conditions: results from the PoCT in General Practice Trial [J].
Bubner, Tanya K. ;
Laurence, Caroline ;
Gialamas, Angela ;
Yelland, Lisa N. ;
Ryan, Philip ;
Willson, Kristyn J. ;
Tideman, Philip ;
Worley, Paul ;
Beilby, Justin J. .
MEDICAL JOURNAL OF AUSTRALIA, 2009, 190 (11) :624-626
[4]  
Coene Karlien L M, 2021, JIMD Rep, V58, P70, DOI 10.1002/jmd2.12186
[5]   Real-world flash glucose monitoring patterns and associations between self-monitoring frequency and glycaemic measures: A European analysis of over 60 million glucose tests [J].
Dunn, Timothy C. ;
Xu, Yongjin ;
Hayter, Gary ;
Ajjan, Ramzi A. .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2018, 137 :37-46
[6]   Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database [J].
Evans, JMM ;
Newton, RW ;
Ruta, DA ;
MacDonald, TM ;
Stevenson, RJ ;
Morris, AD .
BMJ-BRITISH MEDICAL JOURNAL, 1999, 319 (7202) :83-86
[7]   Effect of Dried Blood Spot Quality on Newborn Screening Analyte Concentrations and Recommendations for Minimum Acceptance Criteria for Sample Analysis [J].
George, Roanna S. ;
Moat, Stuart J. .
CLINICAL CHEMISTRY, 2016, 62 (03) :466-475
[8]   Short-Term Stability of Amino acids and Acylcarnitines in the Dried Blood Spots Used to Screen Newborns for Metabolic Disorders [J].
Golbahar, J. ;
Altayab, D. D. ;
Carreon, E. .
JOURNAL OF MEDICAL SCREENING, 2014, 21 (01) :5-9
[9]   Differences of Phenylalanine Concentrations in Dried Blood Spots and in Plasma: Erythrocytes as a Neglected Component for This Observation [J].
Haas, Dorothea ;
Hauke, Jana ;
Schwarz, Kathrin, V ;
Consalvi, Lucia ;
Trefz, Friedrich K. ;
Blau, Nenad ;
Hoffmann, Georg F. ;
Burgard, Peter ;
Garbade, Sven F. ;
Okun, Juergen G. .
METABOLITES, 2021, 11 (10)
[10]   Requirements for a minimum standard of care for phenylketonuria: the patients' perspective [J].
Hagedorn, Tobias S. ;
van Berkel, Paul ;
Hammerschmidt, Gregor ;
Lhotakova, Marketa ;
Saludes, Rosalia Pasqual .
ORPHANET JOURNAL OF RARE DISEASES, 2013, 8