An Investigation of Pharmacokinetic Interaction of Vericiguat with Apigenin based on a Newly Developed Ultra-performance Liquid Chromatography-tandem Mass Spectrometry Assay

被引:1
|
作者
Zhang, En [1 ]
Chen, Chaojie [2 ]
Wang, Yu [3 ,4 ]
Weng, Qinghua [5 ]
Xu, Ren-ai [2 ]
Lin, Jingjing [2 ]
机构
[1] Lihuili Hosp, Ningbo Med Treatment Ctr, Clin Lab, Ningbo, Zhejiang, Peoples R China
[2] Wenzhou Med Univ, Affiliated Hosp 1, Wenzhou, Zhejiang, Peoples R China
[3] Wenzhou Med Univ, Renji Coll, Wenzhou, Zhejiang, Peoples R China
[4] Wenzhou Med Univ, Basic Med Coll, Wenzhou, Zhejiang, Peoples R China
[5] Shanghai Univ, Affiliated Hosp 3, Wenzhou Peoples Hosp, Dept Pharm, Shanghai, Zhejiang, Peoples R China
关键词
Vericiguat; rat plasma; pharmacokinetics; UPLC-MS/MS; plasma; sGC; GLUCURONIDATION;
D O I
10.2174/0109298673258387230921090445
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background Vericiguat, as a new stimulator of soluble guanylate cyclase (sGC), was recently approved as a first-in-class treatment for reducing risks in patients with ejection fraction less than 45 percent and heart failure (HF) in the USA.Objective The main aim of the present experiment was to establish an acceptable, sensitive assay based on ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for quantitatively analyzing the plasma concentration levels of vericiguat in rats, and to further evaluate the effect of apigenin on the metabolism of vericiguat in vivo.Methods In sample processes, acetonitrile was finally chosen for quickly precipitating protein. The levels of vericiguat in plasma were analyzed by a Xevo TQ-S triple quadrupole tandem mass spectrometry (Milford, MA, USA) in a positive ion mode.Results The scope of the calibration standard for vericiguat ranged from 0.5 to 1000 ng/mL, where a great linearity was acceptable. The lower limit of quantification (also called LLOQ) of vericiguat presented the sensitivity of this assay was evaluated as low as 0.5 ng/mL. Additionally, selectivity, accuracy and precision, extraction recovery, matrix effect, and stability were all verified. Subsequently, this approach also supported to assess the plasmatic concentrations of vericiguat from an interaction survey on herb-drug, in which oral administration of apigenin (20 mg/kg) obviously increased the plasmatic levels of vericiguat and altered the pharmacokinetics of vericiguat in rats.Conclusion These results would help us to further understand the pharmacokinetic properties of vericiguat when co-administration with apigenin, and to avoid unexpected clinical risks in the future.
引用
收藏
页码:5468 / 5476
页数:9
相关论文
共 50 条
  • [41] Pharmacokinetic Study of Macitentan in Rat Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Chen, Lianguo
    Yang, Suping
    Liu, Zezheng
    Zhang, Lijing
    Lin, Yingying
    Chen, Minle
    Zhou, Quan
    Wen, Congcong
    Wang, Xuebao
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (07): : 1411 - 1416
  • [42] An investigation on the chemical structure of nitrogen and sulfur codoped carbon nanoparticles by ultra-performance liquid chromatography-tandem mass spectrometry
    Qin Hu
    Xiangpeng Meng
    Wan Chan
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5347 - 5357
  • [43] Pharmacokinetic Study of Colchicine in Rat Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wu, Mingdong
    Shen, Hongwei
    Yang, Suping
    Liu, Zezheng
    Xu, Mengzhi
    Wen, Congcong
    Gao, Gexin
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (01): : 140 - 145
  • [44] An investigation on the chemical structure of nitrogen and sulfur codoped carbon nanoparticles by ultra-performance liquid chromatography-tandem mass spectrometry
    Hu, Qin
    Meng, Xiangpeng
    Chan, Wan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (19) : 5347 - 5357
  • [45] Pharmacokinetic Study of Lithospermoside in Rat Plasma by Ultra-Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry
    Tong, Shuhua
    Song, Huanchun
    Dong, Yanwen
    Jiang, Yanyan
    Yu, Zheng
    Zhou, Ziye
    Geng, Peiwu
    Han, Aixia
    LATIN AMERICAN JOURNAL OF PHARMACY, 2017, 36 (12): : 2411 - 2415
  • [46] Evaluation of QMS Everolimus Assay Using Indiko Analyzer: Comparison With an Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Method
    Buthiau, Delphine
    Bargnoux, Anne-Sophie
    Badiou, Stephanie
    Sutra, Thibault
    Dupuy, Anne-Marie
    Pageaux, Georges-Philippe
    Mourad, Georges
    Cristol, Jean-Paul
    THERAPEUTIC DRUG MONITORING, 2015, 37 (02) : 275 - 278
  • [47] Ultra-performance liquid chromatography-tandem mass spectrometry assay for determination of plasma nomegestrol acetate and estradiol in healthy postmenopausal women
    Nair, Sneha G.
    Patel, Daxesh P.
    Sanyal, Mallika
    Singhal, Puran
    Shrivastav, Pranav S.
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (02)
  • [48] Determination of perfluorocompounds in popcorn packaging by pressurised liquid extraction and ultra-performance liquid chromatography-tandem mass spectrometry
    Pilar Martinez-Moral, Maria
    Teresa Tena, Maria
    TALANTA, 2012, 101 : 104 - 109
  • [49] Determination of nitrofurans metabolites residues in aquatic products by ultra-performance liquid chromatography-tandem mass spectrometry
    Zhang, Yibei
    Qiao, Haiou
    Chen, Chen
    Wang, Zhilun
    Xia, Xiaodong
    FOOD CHEMISTRY, 2016, 192 : 612 - 617
  • [50] Reduction and Hydroxylation Metabolites of Mequindox in Holothurian Analysis by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Li, Yonggang
    Mao, Xin
    Jiang, Lisheng
    Liu, Huihui
    Nie, Xiaoming
    Liu, Xiaohong
    Kong, Fang
    Luo, Ping
    Li, Yanshen
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 61 (03) : 234 - 240