Histamine-Responsive Hydrogel Biosensors Based on Aptamer Recognition and DNA-Driven Swelling Hydrogels

被引:1
作者
Kato, Satofumi [1 ]
Ishiba, Yurika [2 ]
Takinoue, Masahiro [3 ]
Onoe, Hiroaki [1 ,2 ]
机构
[1] Keio Univ, Sch Integrated Design Engn, Grad Sch Sci & Technol, Yokohama, 2238522, Japan
[2] Keio Univ, Fac Sci & Technol, Dept Mech Engn, Yokohama 2238522, Japan
[3] Tokyo Inst Technol, Sch Comp, Dept Comp Sci, Yokohama, 2268501, Japan
来源
ACS APPLIED BIO MATERIALS | 2024年 / 7卷 / 06期
基金
日本学术振兴会;
关键词
biosensor; DNA nanotechnology; aptamer; hydrogel; chemical sensor; PLATFORM; DESIGN;
D O I
10.1021/acsabm.4c00423
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Detection of chemical substances is essential for living a healthy and cultural life in the modern world. One type of chemical sensing technology, biosensing, uses biological components with molecular recognition abilities, enabling a broad spectrum of sensing targets. Short single-stranded nucleic acids called aptamers are one of the biological molecules used in biosensing, and sensing methods combining aptamers and hydrogels have been researched for simple sensing applications. In this research, we propose a hydrogel-based biosensor that uses aptamer recognition and DNA-driven swelling hydrogels for the rapid detection of histamine. Aptamer recognition and DNA-driven swelling hydrogels are directly linked via DNA molecular reactions, enabling rapid sensing. We selected histamine, a major food poisoning toxin, as our sensing target and detected the existence of histamine within 10 min with significance. Because this sensing foundation uses aptamers, which have a vast library of targets, we believe this system can be expanded to various targets, broadening the application of hydrogel-based biosensors.
引用
收藏
页码:4093 / 4101
页数:9
相关论文
共 35 条
[21]   Macroscopic Volume Change of Dynamic Hydrogels Induced by Reversible DNA Hybridization [J].
Peng, Lu ;
You, Mingxu ;
Yuan, Quan ;
Wu, Cuichen ;
Han, Da ;
Chen, Yan ;
Zhong, Zhihua ;
Xue, Jiangeng ;
Tan, Weihong .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2012, 134 (29) :12302-12307
[22]   Progress in hydrogels for sensing applications: a review [J].
Pinelli, F. ;
Magagnin, L. ;
Rossi, F. .
MATERIALS TODAY CHEMISTRY, 2020, 17
[23]   Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor [J].
Radi, AE ;
Sánchez, JLA ;
Baldrich, E ;
O'Sullivan, CK .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (01) :117-124
[24]   Aptamer biosensor for label-free impedance spectroscopy detection of proteins based on recognition-induced switching of the surface charge [J].
Rodriguez, MC ;
Kawde, AN ;
Wang, J .
CHEMICAL COMMUNICATIONS, 2005, (34) :4267-4269
[25]  
Schindelin J, 2012, NAT METHODS, V9, P676, DOI [10.1038/NMETH.2019, 10.1038/nmeth.2019]
[26]   Recent Advances in Aptamer Sensors [J].
Shaban, Samy M. ;
Kim, Dong-Hwan .
SENSORS, 2021, 21 (03) :1-31
[27]   Aptamer-functionalized 2D photonic crystal hydrogels for detection of adenosine [J].
Shen, Peiyan ;
Jang, Kyeongwoo ;
Cai, Zhongyu ;
Zhang, Yuqi ;
Asher, Sanford A. .
MICROCHIMICA ACTA, 2022, 189 (11)
[28]   HISTAMINE POISONING (SCOMBROID FISH POISONING) - AN ALLERGY-LIKE INTOXICATION [J].
TAYLOR, SL ;
STRATTON, JE ;
NORDLEE, JA .
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1989, 27 (4-5) :225-240
[29]   SYSTEMATIC EVOLUTION OF LIGANDS BY EXPONENTIAL ENRICHMENT - RNA LIGANDS TO BACTERIOPHAGE-T4 DNA-POLYMERASE [J].
TUERK, C ;
GOLD, L .
SCIENCE, 1990, 249 (4968) :505-510
[30]   Fabrication of Graphene Microroll Aptasensor [J].
Ueno, Yuko ;
Teshima, Tetsuhiko ;
Henderson, Calum S. ;
Nakashima, Hiroshi .
SENSORS AND MATERIALS, 2018, 30 (12) :2989-2998