Performance of Low-Cost GNSS in Structural Health Monitoring Studies: Shake Table Tests

被引:2
作者
Topal, G. Oku [1 ]
Akpinar, B. [1 ]
Karabulut, M. F. [1 ]
Aykut, N. O. [1 ]
Yigit, C. O. [2 ]
Dindar, A. A. [2 ]
Doran, B. [1 ]
Bezcioglu, M. [2 ]
Zafer, A. [2 ]
Cakmak, Z. B. [1 ]
机构
[1] Yildiz Tekn Univ, Insaat Fak, Istanbul, Turkiye
[2] Gebze Tekn Univ, Insaat Fak, Kocaeli, Turkiye
关键词
Low-cost GNSS; Shake Table; Relative GNSS; GNSS-PPP; GPS; DISPLACEMENT; BRIDGE;
D O I
10.1007/s40799-024-00710-3
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This contribution presents an evaluation of the effectiveness of the low-cost GNSS technique in structural health monitoring and GNSS-seismology applications. To evaluate the ability of the low-cost GNSS technique, harmonic oscillation, and earthquake tests were carried out employing the ZED-F9P-02B OEM low-cost GNSS receiver and two low-cost antennas (A10 and ANN-MB U-Blox) on a single-axis shake table. Harmonic motion experiments include frequencies ranging from 0.35 to 5.80 Hz and amplitudes between 10 and 25 mm. Moreover, the Loma-Prieta and Kobe earthquakes were simulated using a shake table to evaluate the ability of the low-cost GNSS technique to detect earthquake-induced strong ground motions. GNSS observations collected at a 20 Hz sampling interval were processed using the CSRS-PPP online service, and the ability of the low-cost GNSS technique to detect horizontal directional dynamic behaviors was validated using the relative positioning and Linear Variable Differential Transformer (LVDT) data as a reference both time and frequency domain. The max. RMSE values obtained according to the 15 harmonic oscillation test results are 2.8 mm for Geodetic Antenna Relative results, 3.3 mm for PPP, 3.2 mm for A10 Relative, 3.3 mm for PPP, 3.3 mm for UBX Antenna Relative, and 3.7 mm for PPP Results. According to the earthquake test results, the max. RMSE values obtained are 2.6 mm for Geodetic Antenna Relative results, 3.4 mm for PPP, 2.4 mm for A10 Relative, 3.8 mm for A10 PPP, 2.9 mm for UBX Antenna Relative and 4.2 mm for PPP. All results have shown that the ZED-F9P-02B GNSS receiver efficiently detects natural frequencies and structural behaviors.
引用
收藏
页码:977 / 989
页数:13
相关论文
共 33 条
  • [1] Determining the Coordinates of Control Points in Hydrographic Surveying by the Precise Point Positioning Method
    Akpinar, Burak
    Aykut, Nedim Onur
    [J]. JOURNAL OF NAVIGATION, 2017, 70 (06) : 1241 - 1252
  • [2] Analysis of Displacement Response of the Ermenek Dam Monitored by an Integrated Geodetic and Pendulum System
    Alcay, Salih
    Yigit, Cemal Ozer
    Inal, Cevat
    Ceylan, Ayhan
    [J]. INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2018, 16 (10B) : 1279 - 1291
  • [3] [Anonymous], 1987, Guide To GPS Positioning
  • [4] Evaluation of real-time variometric approach and real-time precise point positioning in monitoring dynamic displacement based on high-rate (20 Hz) GPS Observations
    Bezcioglu, Mert
    Yigit, Cemal Ozer
    Karadeniz, Baris
    Dindar, Ahmet Anil
    El-Mowafy, Ahmed
    Avci, Ozgur
    [J]. GPS SOLUTIONS, 2023, 27 (01)
  • [5] High-rate (20 Hz) single-frequency GPS/GALILEO variometric approach for real-time structural health monitoring and rapid risk assessment
    Bezcioglu, Mert
    Yigit, Cemal Ozer
    Mazzoni, Augusto
    Fortunato, Marco
    Dindar, Ahmet Anil
    Karadeniz, Baris
    [J]. ADVANCES IN SPACE RESEARCH, 2022, 70 (05) : 1388 - 1405
  • [6] GPS in pioneering dynamic monitoring of long-period structures
    Çelebi, M
    Sanli, A
    [J]. EARTHQUAKE SPECTRA, 2002, 18 (01) : 47 - 61
  • [7] Dindar A.A., 2018, 16 EUR C EARTHQ ENG
  • [8] Ambient Vibration Measurements of the Bosphorus Suspension Bridge by Total Station and GPS
    Erdogan, H.
    Gulal, E.
    [J]. EXPERIMENTAL TECHNIQUES, 2013, 37 (03) : 16 - 23
  • [9] Erdogan H, 2006, THESIS YILDIZ TU FEN
  • [10] Dynamic characteristic of tall industrial chimney estimated from GPS measurement and frequency domain decomposition
    Gorski, Piotr