Open-Circuit Fault Diagnosis Method for Grid-Tied T-Type Converters Based on Harr-Like Features

被引:0
作者
Wu, Zhixi [1 ]
Zhao, Jin [1 ]
Yu, Wei [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Artificial Intelligence & Automat, Key Lab Imaging Proc & Intelligence Control, Wuhan 430074, Peoples R China
[2] Easy Grp Co Ltd, Dongguan, Peoples R China
基金
中国国家自然科学基金;
关键词
Circuit faults; Transistors; Inverters; Integrated circuit modeling; Feature extraction; Topology; Fault location; Fault diagnosis; grid-tied T-type converter; Harr-like feature; open-circuit fault; OPEN-SWITCH FAULT; VOLTAGE VECTOR; 3-LEVEL INVERTERS;
D O I
10.1109/JESTPE.2024.3396230
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The grid-tied T-type converter can work in the rectifier state and the inverter state. The open-circuit fault diagnosis under the two conditions faces the challenge of fault detection and fault location, respectively. An open-circuit fault diagnosis method for grid-tied T-type converters based on Harr-like features is proposed in this article, considering both the rectifier and the inverter states. The Harr-like features are a set containing two-rectangle features (2RF) at different scales and three-rectangle features (3RF). The diagnosis is a step-by-step process. At first, a small-scale 2RF is used to represent the weak fault information. In addition, the fault is enhanced and detected by the average magnitude difference function (AMDF). In the fault phase location, the Pearson correlation coefficients of the three-phase currents are calculated with a period-scale 2RF. The coefficients are also used to distinguish between the outer transistor fault and the inner transistor fault in the rectifier state. When the former is obtained, the fault transistor is located according to the features at the first step. For the other condition, the fault transistor is located by the features extracted from a period-scale 2RF and a three-half period-scale 3RF. Only the three-phase current signals are needed, without other signals and parameters. The experimental results verify the effectiveness of the proposed diagnosis method.
引用
收藏
页码:3900 / 3911
页数:12
相关论文
共 35 条
[21]   Online Fault Diagnosis Method for Grid-Tied T-Type Inverters Based on Specific Frequency Calculation [J].
Wu, Zhixi ;
Zhao, Jin ;
Liu, Yang ;
Zhou, Yang .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (05) :5364-5375
[22]   Real-Time Open-Circuit Fault Diagnosis Method for T-Type Rectifiers Based on Median Current Analysis [J].
Wu, Zhixi ;
Zhao, Jin ;
Luo, Hui ;
Liu, Yang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (07) :8956-8965
[23]   An Open-Circuit Fault Diagnosis Method for Four-Wire T-Type Three-Level Rectifier [J].
Wu, Zhixi ;
Sun, Jiajiang ;
Song, Yujin ;
Zhao, Jin .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (01) :1045-1055
[24]   Open-Circuit Fault Diagnosis Method for Grid-Connected Bidirectional T-Type Converter Based on Geometrical Similarity Measurement [J].
Wu, Zhixi ;
Zhao, Jin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (12) :15571-15582
[25]   A Reduced-Order Observer-Based Method for Simultaneous Diagnosis of Open-Switch and Current Sensor Faults of a Grid-Tied NPC Inverter [J].
Xu, Shuiqing ;
Huang, Wenzhan ;
Huang, Darong ;
Chen, Hongtian ;
Chai, Yi ;
Ma, Mingyao ;
Zheng, Wei Xing .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (07) :9019-9032
[26]   A Simultaneous Diagnosis Method for Power Switch and Current Sensor Faults in Grid-Connected Three-Level NPC Inverters [J].
Xu, Shuiqing ;
Huang, Wenzhan ;
Wang, Hai ;
Zheng, Weixing ;
Wang, Juxing ;
Chai, Yi ;
Ma, Mingyao .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (01) :1104-1118
[27]   An Industry-Based Survey of Reliability in Power Electronic Converters [J].
Yang, Shaoyong ;
Bryant, Angus ;
Mawby, Philip ;
Xiang, Dawei ;
Ran, Li ;
Tavner, Peter .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (03) :1441-1451
[28]   A survey of fault diagnosis for onshore grid-connected converter in wind energy conversion systems [J].
Yang, Zhimin ;
Chai, Yi .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 66 :345-359
[29]   A Unified Open-Circuit Fault Diagnosis and Condition Monitoring Method for Three-Level T-Type Inverter [J].
Zhang, Weiwei ;
He, Yigang ;
Chen, Jianfei ;
Du, Bolun .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (04) :5376-5391
[30]   A Robust Open-Circuit Fault Diagnosis Method for Three-Level T-Type Inverters Based on Phase Voltage Vector Residual Under Modulation Mode Switching [J].
Zhang, Weiwei ;
He, Yigang ;
Chen, Jianfei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (04) :5309-5322