Effect of humeral rotation on the reliability of radiographic measurements for proximal humerus fractures

被引:0
作者
Sepehri, Aresh [1 ]
Stockton, David J. [1 ,2 ]
Roffey, Darren M. [1 ,2 ]
Lefaivre, Kelly A. [1 ,2 ]
Potter, Jeffrey M. [1 ,2 ]
Guy, Pierre [1 ,2 ]
机构
[1] Univ British Columbia, Fac Med, Gordon & Leslie Diamond Hlth Care Ctr, Dept Orthopaed, 1th Floor,2775 Laurel St, Vancouver, BC V5Z 1M9, Canada
[2] Vancouver Gen Hosp, Gordon & Leslie Diamond Hlth Care Ctr, Div Orthopaed Trauma, Vancouver Coastal Hlth, 3rd Floor, Vancouver, BC V5Z 1M9, Canada
关键词
Proximal humerus fracture; Shoulder; Radiograph; Reliability; Surgery; Rotation; Intra-class correlation; LOCKING PLATE; SHAFT ANGLE; FIXATION; OSTEOSYNTHESIS; COMPLICATIONS; EPIDEMIOLOGY; FAILURE; IMPACT;
D O I
10.1016/j.jos.2023.06.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: There are concerns as to the reliability of proximal humerus radiographic measurements, particularly regarding the rotational position of the humerus when obtaining radiographs. Methods: Twenty-four patients with proximal humerus fractures fixed surgically with locked plates received postoperative anteroposterior radiographs with the humerus in neutral rotation and in 30 degrees of internal and external rotation. Radiographic measurements for head shaft angle, humeral offset and humeral head height were performed in each humeral rotation position. Intra-class correlation coefficient was used to assess inter-rater and intra-rater reliability. Mean differences (md) in measurements between humeral positions was evaluated using one-way ANOVA. Results: Head shaft angle demonstrated good-to-excellent reliability; the highest estimates for interrater reliability (ICC: 0.85; 95% CI: 0.76, 0.94) and intra-rater reliability (ICC: 0.96; 95% CI: 0.93, 0.98) were achieved in neutral rotation. There were significant differences in measurement values between each rotational position, with mean head shaft angle of 133.1 degrees in external rotation, and increasingly valgus measurements in neutral (md: 7.6 degrees; 95% CI: 5.0, 10.3 degrees; p < 0.001) and internal rotation (md: 26.4 degrees; 95% CI: 21.8, 30.9 degrees; p < 0.001). Humeral head height and humeral offset showed good-to-excellent reliability in neutral and external rotation, but poor inter-rater reliability in internal rotation. Humeral head height was significantly greater using internal compared to external rotation (md: 4.5 mm; 95% CI: 1.7, 7.3 mm; p = 0.002). Humeral offset was significantly greater in external compared to internal rotation (md: 4.6 mm; 95% CI: 2.6, 6.6 mm; p < 0.001). Conclusions: Views of the humerus in neutral rotation and 30 degrees of external rotation displayed superior reliability. Differences in radiographic measurement values, depending on humeral rotation views, can make for problematic correlations with patient outcome measures. Studies assessing radiographic outcomes following proximal humerus fractures should ensure standardized humeral rotation for obtaining anteroposterior shoulder radiographs, with neutral rotation and external rotation views likely yielding the most reliable results. Level of Evidence: Level IV (c) 2023 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:1078 / 1084
页数:7
相关论文
共 30 条
[1]   Head-shaft angle changes during internal and external shoulder rotations: 2-D angulation in 3-D space [J].
Adikrishna, A. ;
Hong, H. ;
Deslivia, M. F. ;
Zhu, B. ;
Tan, J. ;
Jeon, I. -H. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) :159-163
[2]   Minimally invasive polyaxial locking plate osteosynthesis for 3-4 part proximal humeral fractures: our institutional experience [J].
Aguado, Hector J. ;
Mingo, Juan ;
Torres, Miguel ;
Alvarez-Ramos, Aranzazu ;
Martin-Ferrero, Miguel A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 :S22-S28
[3]   Impact of shoulder rotation on neck-shaft angle: A clinical study [J].
Assuncao, J. H. ;
Malavolta, E. A. ;
Beraldo, R. A. ;
Gracitelli, M. E. C. ;
Bordalo-Rodrigues, M. ;
Ferreira Neto, A. A. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (06) :865-868
[4]  
Bahrs C, 2014, INT ORTHOP, V38, P1697, DOI 10.1007/s00264-014-2362-6
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Kapandji pinning and tuberosities fixation of three- and four-part fractures of the proximal humerus [J].
Bonnevialle, Nicolas ;
Ibnoulkatib, Aissa ;
Mansat, Pierre ;
Bonnevialle, Paul .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) :1965-1971
[7]   Percutaneous fixation of displaced proximal humeral fractures:: Indications based on the correlation between clinical and radiographic results [J].
Calvo, Emilio ;
de Miguel, Ignacio ;
de la Cruz, Juan J. ;
Lopez-Martin, Nestor .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (06) :774-781
[8]   Nondisplaced proximal humeral fractures: high incidence among outpatient-treated osteoporotic fractures and severe impact on upper extremity function and patient subjective health perception [J].
Calvo, Emilio ;
Morcillo, Diana ;
Foruria, Antonio M. ;
Redondo-Santamar, Enrique ;
Osorio-Picorne, Fernando ;
Caeiro, Jose R. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (05) :795-801
[9]   Pitfalls and complications with locking plate for proximal humerus fracture [J].
Clavert, Philippe ;
Adam, Philippe ;
Bevort, Adrien ;
Bonnomet, Francois ;
Kempf, Jean-Francois .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) :489-494
[10]   Fibular strut allograft influences reduction and outcomes after locking plate fixation of comminuted proximal humeral fractures in elderly patients: a retrospective study [J].
Cui, Xueliang ;
Chen, Hui ;
Ma, Binbin ;
Fan, Wenbin ;
Li, He .
BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)