Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design

被引:0
作者
Fernandez-Nunez, Sara [1 ]
Perez-Sanz, Lidia [2 ,3 ]
Gomez-Pedrero, Jose Antonio [1 ]
Garcia-Montero, Maria [2 ]
Albarran-Diego, Cesar [4 ]
Garzon, Nuria [2 ]
机构
[1] Univ Complutense Madrid, Dept Opt, Ave Arcos Jalon 118, E-28037 Madrid, Spain
[2] Univ Complutense Madrid, Dept de Optometria & Vis, Ave Arcos Jalon 118, E-28037 Madrid, Spain
[3] Miranza IOA, Calle Galileo, 104, Madrid 28003, Spain
[4] Univ Valencia, Dept Opt & Optometria & Ciencias Vis, Doctor Moliner 50, Burjassot 46100, Spain
关键词
IOL; EDoF; Optical quality; Optical bench; VISUAL-ACUITY; METRICS; PREDICT;
D O I
10.1007/s00417-024-06590-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeThe aim of this study is to compare optical quality results obtained in laboratory analysis (in vitro) versus clinical data (in vivo).MethodsThe optical quality of ISOPure intraocular lens was assessed both in vitro and in vivo using the modulation transfer function (MTF) for 3.0 and 4.5 mm pupil diameters. In vitro measurements were obtained using deflectometer NIMO TRF1504, while in vivo measurements were taken with OPD-Scan III in a set of patients implanted with this lens. Ray tracing techniques were used to determine the MTF and area under MTF curve (MTFa) from the measured wavefront for the isolated lens and for the whole eye.ResultsThe MTF of the isolated lens obtained under both in vitro and in vivo conditions showed comparable results for both pupil sizes. However, differences were found when comparing the MTF of the whole eye with the lens implanted versus the MTF measured in vitro for 4.5 mm pupil size. Also, the MTFa defocus curve was compared with the defocus curve measured in vivo.ConclusionThe defocus curve from the in vivo study aligns closely with the MTFa of the in vitro model, with a useful defocus range of 0.40D. Thus, it is possible to anticipate the visual results of the implanted isofocal lens by using measurements on an optical bench and conducting optical simulations. What is known center dot Extended depth of focus (EDoF) lenses are prominent for expanding vision range in pseudophakic eyes, exceeding traditional limits.center dot The ISOPure lens is characterized as a bi-aspheric refractive design that produces an extended depth of focus design.What is new center dot The MTF of the isolated lens obtained under both in vitro and in vivo conditions showed comparable results.center dot The defocus curve from the in vivo study aligns closely with the MTFa of the in vitro model, with a useful defocus range of 0.40D.
引用
收藏
页码:3905 / 3913
页数:9
相关论文
共 50 条
  • [41] Comparative Visual Outcome Analysis of a Diffractive Multifocal Intraocular Lens and a New Diffractive Multifocal Lens with Extended Depth of Focus
    Moshirfar, Majid
    Stapley, Seth R.
    Corbin, Wyatt M.
    Bundogji, Nour
    Conley, Matthew
    Darquea, Ines M.
    Ronquillo, Yasmyne C.
    Hoopes, Phillip C.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [42] A comparative study of two presbyopia-correcting intraocular lenses combining bifocal and extended depth-of-focus profiles
    Kim, Jeongmin
    Kim, Tae-im
    Seo, Kyoung Yul
    Tchah, Hungwon
    Koh, Kyungmin
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [43] The Postoperative Visual and Refractive Outcomes of Trifocal and Extended Depth-of-Focus Intraocular Lenses in Patients with Different Biometric Characteristics
    Lee, Chia-Yi
    Chen, Hung-Chi
    Lian, Ie-Bin
    Huang, Jing-Yang
    Yang, Shun-Fa
    Chang, Chao-Kai
    DIAGNOSTICS, 2024, 14 (16)
  • [44] Extended depth of focus intraocular lenses for presbyopia
    Akella, Sruti S.
    Juthani, Viral V.
    CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) : 319 - 323
  • [45] Silver mean sequence in extended depth of focus intraocular lenses: a comparative study of kinoform and stepwise designs
    Martinez-espert, Anabel
    Ferrando, Vicente
    Garmendia-martinez, Adrian
    Munoz-perez, Francisco m.
    Monsoriu, Juan a.
    Furlan, Walter d.
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (12): : 6999 - 7012
  • [46] Comparison of two extended depth of focus intraocular lenses with a monofocal lens: a multi-centre randomised trial
    Reinhard, Thomas
    Maier, Philip
    Boehringer, Daniel
    Bertelmann, Eckart
    Brockmann, Tobias
    Kiraly, Laszlo
    Salom, David
    Piovella, Matteo
    Colonval, Stephane
    Mendicute, Javier
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (02) : 431 - 442
  • [47] Correlation between pupillary size and depth of focus after the implantation of extended depth of focus intraocular lenses
    Fang, Xiaoling
    Xue, Wenwen
    Yu, Chunxia
    Tao, Jinhua
    Wang, Yulan
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (12) : 3897 - 3903
  • [48] Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1861 - 1869
  • [49] Comparison of modal and zonal wavefront measurements of refractive extended depth of focus intraocular lenses
    Bang, Seung Pil
    Jung, HaeWon
    Li, Kaccie Y.
    Yoon, Geunyoung
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (03) : 1618 - 1629
  • [50] Preliminary Clinical Outcomes of a New Enhanced Depth of Focus Intraocular Lens
    Campos, Nuno
    Loureiro, Tomas
    Rodrigues-Barros, Sandra
    Carreira, Ana Rita
    Gouveia-Moraes, Filipe
    Carreira, Pedro
    Machado, Ines
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 4801 - 4807