The exploration of a compound cone-beam CT contrast agent for diagnosis of human extracted cracked tooth

被引:1
|
作者
Hu, Ziyang [1 ,2 ]
Hu, Yanni [1 ]
Xu, Shi [3 ]
Zhuang, Jia [1 ]
Cao, Dantong [1 ]
Gao, Antian [1 ]
Xie, Xin [4 ]
Lin, Zitong [1 ]
机构
[1] Nanjing Univ, Med Sch, Dept Dentomaxillofacial Radiol, Nanjing Stomatol Hosp,Affiliated Hosp,Inst Stomat, Zhong Yang Rd 30, Nanjing 210008, Jiangsu, Peoples R China
[2] Shenzhen Longhua Dist Cent Hosp, Dept Stomatol, Shenzhen, Peoples R China
[3] Nanjing Univ, Nanjing Stomatol Hosp, Affiliated Hosp, Inst Stomatol,Med Sch,Dept Endodont, Nanjing, Peoples R China
[4] Third Peoples Hosp Danyang City, Dept Stomatol, Danyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cracked tooth; Cone -beam CT; Contrast agent; Sodium iodide; Delay time; OPTICAL COHERENCE TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; COMPUTED-TOMOGRAPHY; ENAMEL CRACKS; TEETH; BIOFILM; ACCURACY; ETHANOL;
D O I
10.1016/j.heliyon.2024.e31036
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: This study aims to investigate the use of sodium iodide (NaI), dimethyl sulfoxide (DMSO), ethyl alcohol, and ethyl acetate as cone-beam CT (CBCT) contrast agents for diagnosing cracked teeth. The optimal delay time for detecting the number of crack lines beyond the dentinoenamel junction (Nd), the number of cracks extending from the occlusal surface to the pulp cavity (Np), and the depth of the crack lines was explored. Methods: 14 human extracted cracked teeth were collected, 12 were used for enhanced scanning, and 2 were used for exploring the characteristic of crack lines. The teeth were scanned in 3 CBCT enhanced scanning (ES) modes: ES1 using meglumine diatrizoate (MD); ES2 using NaI and DMSO, ES3 using NaI, DMSO, ethyl alcohol and ethyl acetate. Three delay times (15mins, 30mins, and 60mins) were set for scanning. Nd, Np, and depth of crack lines were evaluated. Results: There were totally 24 crack lines on 12 cracked teeth. Nd was 10 in ES1 at 60mins, 24 in ES2 at 60mins and 24 in ES3 at 15mins. Np was 1 in ES1 at 60mins, 10 in ES2 at 60mins and 21 in ES3 at 60mins, and there were significantly different among them (p < 0.01). The average depth presented on ES3 was significantly deeper than ES1 and ES2 (p < 0.01). Conclusion: NaI, DMSO, ethyl alcohol and ethyl acetate show potential as contrast agents for enhanced CBCT scanning in diagnosis of cracked teeth and their depth in vivo. A delay time of 15 min is necessary to confirm the existence of crack lines, while a longer delay time is required to ascertain if these crack lines extend to the pulp cavity.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Low-contrast Visualization in Megavoltage Cone-beam CT at one Beam Pulse per Projection using Thick, Segmented Scintillators
    El-Mohri, Youcef
    Antonuk, Larry E.
    Zhao, Qihua
    Choroszucha, Richard B.
    Wang, Yi
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [42] Impacted Lower Third Molar Fused with a Supernumerary Tooth - Diagnosis and Treatment Planning Using Cone-Beam Computed Tomography
    Ferreira-Junior, Osny
    de Avila, Luciana Dorigatti
    da Silva Sampieri, Marcelo Bonifacio
    Dias-Ribeiro, Eduardo
    Chen, Wei-liang
    Fan, Song
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2009, 1 (04) : 224 - 228
  • [43] Simultaneous Image Reconstruction and Element Decomposition for Iodine Contrast Agent Visualization in Multienergy Element-Resolved Cone Beam CT
    Wang, Chao
    Jung, Hyunuk
    Yang, Ming
    Shen, Chenyang
    Jia, Xun
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [44] Deep learning-enabled 3D multimodal fusion of cone-beam CT and intraoral mesh scans for tooth-bone reconstruction
    Liu, Jiaxiang
    Hao, Jin
    Lin, Hangzheng
    Pan, Wei
    Yang, Jianfei
    Feng, Yang
    Wang, Gaoang
    Li, Jin
    Jin, Zuolin
    Zhao, Zhihe
    Liu, Zuozhu
    PATTERNS, 2023, 4 (09):
  • [45] Cone-Beam CT for Neurosurgical Guidance: High-Fidelity Artifacts Correction for Soft-Tissue Contrast Resolution
    Wu, P.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Ketcha, M.
    Jones, C. K.
    Vagdargi, P.
    Zhang, X.
    Luciano, M.
    Anderson, W. S.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [46] MRCM-UCTransNet: Automatic and Accurate 3D Tooth Segmentation Network From Cone-Beam CT Images
    Wen, Xinyang
    Liu, Zhuoxuan
    Chu, Yanbo
    Le, Min
    Li, Liang
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2024, 34 (04)
  • [47] Determination of a cone-beam CT low-dose protocol for root fracture diagnosis in non-endodontically treated anterior maxillary teeth
    Yalda, Fedil Andraws
    Theodorakou, Chrysoula
    Clarkson, Rosalyn J.
    Davies, Jonathan
    Feinberg, Lee
    Sengupta, Anita
    Horner, Keith
    DENTOMAXILLOFACIAL RADIOLOGY, 2022, 51 (02)
  • [48] Distinguishing benign and malignant lesions on contrast-enhanced breast cone-beam CT with deep learning neural architecture search
    Ma, Jingchen
    He, Ni
    Yoon, Jin H.
    Ha, Richard
    Li, Jiao
    Ma, Weimei
    Meng, Tiebao
    Lu, Lin
    Schwartz, Lawrence H.
    Wu, Yaopan
    Ye, Zhaoxiang
    Wu, Peihong
    Zhao, Binsheng
    Xie, Chuanmiao
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 142
  • [49] Contrast-enhanced cone-beam breast-CT: Analysis of optimal acquisition time for discrimination of breast lesion malignancy
    Uhlig, Johannes
    Fischer, Uwe
    Surov, Alexey
    Lotz, Joachim
    Wienbeck, Susanne
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 9 - 16
  • [50] Enhancement of soft-tissue contrast in cone-beam CT using an anti-scatter grid with a sparse sampling approach
    Cho, Sanghoon
    Lim, Sunho
    Kim, Changhwan
    Wi, Sunhee
    Kwon, Taejin
    Youn, Won Sik
    Lee, Sang Hyun
    Kang, Bo Sun
    Cho, Seungryong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 70 : 1 - 9