The exploration of a compound cone-beam CT contrast agent for diagnosis of human extracted cracked tooth

被引:1
|
作者
Hu, Ziyang [1 ,2 ]
Hu, Yanni [1 ]
Xu, Shi [3 ]
Zhuang, Jia [1 ]
Cao, Dantong [1 ]
Gao, Antian [1 ]
Xie, Xin [4 ]
Lin, Zitong [1 ]
机构
[1] Nanjing Univ, Med Sch, Dept Dentomaxillofacial Radiol, Nanjing Stomatol Hosp,Affiliated Hosp,Inst Stomat, Zhong Yang Rd 30, Nanjing 210008, Jiangsu, Peoples R China
[2] Shenzhen Longhua Dist Cent Hosp, Dept Stomatol, Shenzhen, Peoples R China
[3] Nanjing Univ, Nanjing Stomatol Hosp, Affiliated Hosp, Inst Stomatol,Med Sch,Dept Endodont, Nanjing, Peoples R China
[4] Third Peoples Hosp Danyang City, Dept Stomatol, Danyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Cracked tooth; Cone -beam CT; Contrast agent; Sodium iodide; Delay time; OPTICAL COHERENCE TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; COMPUTED-TOMOGRAPHY; ENAMEL CRACKS; TEETH; BIOFILM; ACCURACY; ETHANOL;
D O I
10.1016/j.heliyon.2024.e31036
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: This study aims to investigate the use of sodium iodide (NaI), dimethyl sulfoxide (DMSO), ethyl alcohol, and ethyl acetate as cone-beam CT (CBCT) contrast agents for diagnosing cracked teeth. The optimal delay time for detecting the number of crack lines beyond the dentinoenamel junction (Nd), the number of cracks extending from the occlusal surface to the pulp cavity (Np), and the depth of the crack lines was explored. Methods: 14 human extracted cracked teeth were collected, 12 were used for enhanced scanning, and 2 were used for exploring the characteristic of crack lines. The teeth were scanned in 3 CBCT enhanced scanning (ES) modes: ES1 using meglumine diatrizoate (MD); ES2 using NaI and DMSO, ES3 using NaI, DMSO, ethyl alcohol and ethyl acetate. Three delay times (15mins, 30mins, and 60mins) were set for scanning. Nd, Np, and depth of crack lines were evaluated. Results: There were totally 24 crack lines on 12 cracked teeth. Nd was 10 in ES1 at 60mins, 24 in ES2 at 60mins and 24 in ES3 at 15mins. Np was 1 in ES1 at 60mins, 10 in ES2 at 60mins and 21 in ES3 at 60mins, and there were significantly different among them (p < 0.01). The average depth presented on ES3 was significantly deeper than ES1 and ES2 (p < 0.01). Conclusion: NaI, DMSO, ethyl alcohol and ethyl acetate show potential as contrast agents for enhanced CBCT scanning in diagnosis of cracked teeth and their depth in vivo. A delay time of 15 min is necessary to confirm the existence of crack lines, while a longer delay time is required to ascertain if these crack lines extend to the pulp cavity.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Accuracy of intraoral radiography, multidetector helical CT, and limited cone-beam CT for the detection of horizontal tooth root fracture
    Iikubo, Masahiro
    Kobayashi, Kaoru
    Mishima, Akira
    Shimoda, Shinji
    Daimaruya, Takayoshi
    Igarashi, Chinami
    Imanaka, Masahiro
    Yuasa, Masao
    Sakamoto, Maya
    Sasano, Takashi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (05): : E70 - E74
  • [22] Could Low-dose Cone-beam CT be Used for Endodontic Intraoperative Diagnosis?
    de Lima, Joao Pedro
    Mazzi-Chaves, Jardel Francisco
    de Sousa-Neto, Manoel Damiao
    Candemil, Amanda Pelegrin
    JOURNAL OF ENDODONTICS, 2023, 49 (09) : 1161 - 1168
  • [23] Virtual bronchoscopic navigation with intraoperative cone-beam CT for the diagnosis of peripheral pulmonary nodules
    Zhang, Jisong
    Chen, Enguo
    Xu, Shan
    Xu, Li
    Hu, Huihui
    Dong, Liangliang
    Ying, Kejing
    BMC PULMONARY MEDICINE, 2024, 24 (01)
  • [24] A fully automatic AI system for tooth and alveolar bone segmentation from cone-beam CT images
    Cui, Zhiming
    Fang, Yu
    Mei, Lanzhuju
    Zhang, Bojun
    Yu, Bo
    Liu, Jiameng
    Jiang, Caiwen
    Sun, Yuhang
    Ma, Lei
    Huang, Jiawei
    Liu, Yang
    Zhao, Yue
    Lian, Chunfeng
    Ding, Zhongxiang
    Zhu, Min
    Shen, Dinggang
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [25] Contrast Enhancement on Cone-Beam Breast-CT for Discrimination of Breast Cancer Immunohistochemical Subtypes
    Uhlig, Johannes
    Fischer, Uwe
    von Fintel, Eva
    Stahnke, Vera
    Perske, Christina
    Lotz, Joachim
    Wienbeck, Susanne
    TRANSLATIONAL ONCOLOGY, 2017, 10 (06): : 904 - 910
  • [26] Cone-Beam CT image contrast and attenuation-map linearity improvement (CALI) for brain stereotactic radiosurgery procedures
    Hashemi, SayedMasoud
    Huynh, Christopher
    Sahgal, Arjun
    Song, William Y.
    Nordstrom, Hakan
    Eriksson, Markus
    Mainprize, James G.
    Lee, Young
    Ruschin, Mark
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 200 - 208
  • [27] Angiography with cone-beam CT versus contrast-enhanced MRI for living donor transplant imaging: Is MRI enough?
    Ali, Hamza
    Weinstein, Jeffrey
    Sarwar, Ammar
    Evenson, Amy
    Raven, Kristin
    Curry, Michael P.
    Ahmed, Muneeb
    CLINICAL ANATOMY, 2024, 37 (02) : 185 - 192
  • [28] A Diagnosis of Maxillary Sinus Fracture with Cone-Beam CT: Case Report and Literature Review
    Yilmaz, Selmi Yardimci
    Misirlioglu, Melda
    Adisen, Mehmet Zahit
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2014, 7 (02) : 85 - 91
  • [29] Virtual bronchoscopic navigation with intraoperative cone-beam CT for the diagnosis of peripheral pulmonary nodules
    Jisong Zhang
    Enguo Chen
    Shan Xu
    Li Xu
    Huihui Hu
    Liangliang Dong
    Kejing Ying
    BMC Pulmonary Medicine, 24
  • [30] 3D morphometric analysis of the human incudomallear complex using clinical cone-beam CT
    Soons, Joris A. M.
    Danckaers, Femke
    Keustermans, William
    Huysmans, Toon
    Sijbers, Jan
    Casselman, Jan W.
    Dirckx, Joris J. J.
    HEARING RESEARCH, 2016, 340 : 79 - 88