Lightning-induced voltages on low-voltage distribution lines

被引:2
作者
Piantini, Alexandre [1 ]
机构
[1] Univ Sao Paulo, Inst Energy & Environm, Ave Prof Luciano Gualberto 1289, BR-05508010 Sao Paulo, SP, Brazil
关键词
Electromagnetic transients; Indirect lightning; Lightning -induced voltages; Low -voltage lines; Overvoltages; ELECTROMAGNETIC-FIELDS; OVERHEAD LINES; PERFORMANCE;
D O I
10.1016/j.epsr.2024.110526
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Special attention has been drawn to transients in low-voltage systems in recent years. As the surge withstand capabilities of low-voltage networks are much lower than those of medium-voltage lines, they are more susceptible to lightning-caused disturbances. One of the primary sources of overvoltages is related to indirect lightning strokes. Such overvoltages are highly dependent on the soil characteristics and generally tend to increase with the soil resistivity. Considering realistic conditions, this paper discusses the effects of different parameters on the phase-to-ground and phase-to-neutral lightning-induced voltages on the low-voltage side of a typical distribution transformer. In the case of high-resistivity soils or high ground resistance values, phase-toground voltages induced by indirect strokes can reach several tens of kilovolts. Phase-to-neutral voltages higher than 5 kV may be common if surge protective devices are not applied.
引用
收藏
页数:8
相关论文
共 49 条
  • [1] A Correction to Rusck Expression for the Evaluation of Lightning-Induced Overvoltages for High-Resistivity Ground
    Ain, Noor Ul
    Andreotti, Amedeo
    Mahmood, Farhan
    Rizk, Mohammad E. M.
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2023, 65 (04) : 1152 - 1161
  • [2] Anderson R.B., 1979, Elektra., P65
  • [3] ATP, 1987, Alternative Transients Program Rule Book.
  • [4] An approximate time-domain formula for the calculation of the horizontal electric field from lightning
    Barbosa, Celio Fonseca
    Paulino, Jose Osvaldo Saldanha
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2007, 49 (03) : 593 - 601
  • [5] Lightning-Induced Overvoltages Transferred Through Distribution Power Transformers
    Borghetti, Alberto
    Morched, Atef
    Napolitano, Fabio
    Nucci, Carlo Alberto
    Paolone, Mario
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 360 - 372
  • [6] The influence of seasonal soil moisture on the behavior of soil resistivity and power distribution grounding systems
    Coelho, Vilson Luiz
    Piantini, Alexandre
    Almaguer, Hugo A. D.
    Coelho, Rafael A.
    Boaventura, Wallace do C.
    Paulino, Jose Osvaldo S.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2015, 118 : 76 - 82
  • [7] Cooray Vernon, 2003, The Lightning Flash, P127, DOI 10.1049/PBPO034E_ch4
  • [8] THE GENERALIZED INTEGRATION METHOD FOR PREDICTING IMPULSE VOLT-TIME CHARACTERISTICS FOR NON-STANDARD WAVE SHAPES - A THEORETICAL BASIS
    DARVENIZA, M
    VLASTOS, AE
    [J]. IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1988, 23 (03): : 373 - 381
  • [9] De Conti A., 2005, P 7 INT S LIGHTN PRO, P483
  • [10] LOW-VOLTAGE SIDE CURRENT-SURGE PHENOMENA IN SINGLE-PHASE DISTRIBUTION TRANSFORMER SYSTEMS
    DUGAN, RC
    SMITH, SD