Pulsed eddy current testing of ferromagnetic specimen based on variable pulse width excitation

被引:23
|
作者
Li, Jian [1 ]
Wu, Xinjun [1 ]
Zhang, Qing [1 ]
Sun, Pengfei [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan 430074, Hubei Province, Peoples R China
基金
中国国家自然科学基金;
关键词
Pulsed eddy current testing; Variable pulse width excitation; Quantitative detection; Ferromagnetic specimen;
D O I
10.1016/j.ndteint.2014.09.004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Pulsed eddy current testing (PECT) is a rapidly developing technology which has wide potential applications. For the PECT system which uses detection coils, a no-reference-needed and more efficient method, for quantifying the wall thickness of the ferromagnetic specimen, should be found. In this paper, a kind of variable pulse width excitation is proposed. Based on the excitation, the slope that the relative increment of magnetic flux linear decays with the increase of pulse width in the semi-logarithmic domain is found to be an effective and no-reference-needed feature. First, the analytical expression for the relative increment of magnetic flux is presented, and the validity of the feature is verified by experiments. Then the potential factors affecting the feature are investigated in detail. Results show that when the electromagnetic properties of the specimen are invariant, the feature is independent of pulse width parameters, analysis interval and coatings thickness. At last, a quantitative method is demonstrated. More time could be saved for the narrow pulse comparing it with the existing excitations, and the feature could widely meet engineering applications. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 50 条
  • [1] Analysis of excitation current parameters in pulsed eddy current testing for ferromagnetic metallic materials
    Xu, Zhiyuan
    Wu, Xinjun
    Huang, Chen
    Ke, Hai
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2012, 39 (1-4) : 213 - 219
  • [2] Defect depth estimation using pulsed eddy current with varied pulse width excitation
    Abidin, I. Zainal
    Mandache, C.
    Tian, G. Y.
    Li, Yong
    INSIGHT, 2009, 51 (02) : 69 - 72
  • [3] Pulsed eddy current nondestructive testing of ferromagnetic tubes
    Vasic, D
    Bilas, V
    Ambrus, D
    IMTC/O3: PROCEEDINGS OF THE 20TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1 AND 2, 2003, : 1120 - 1125
  • [4] Numerical Analysis of Through Transmission Pulsed Eddy Current Testing and Effects of Pulse Width Variation
    Shin, Young-Kil
    Choi, Dong-Myung
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2007, 27 (03) : 255 - 261
  • [5] Transient eddy current response to pulsed eddy current testing inside a ferromagnetic casing
    Sun, Hu
    Shi, Yibing
    Zhang, Wei
    Li, Yanjun
    NDT & E INTERNATIONAL, 2022, 126
  • [6] Yield Strength Testing Method of Ferromagnetic Materials Based on Pulsed Eddy Current
    Li K.
    Gao W.
    Wang P.
    Zhang Y.
    Hang C.
    Zhongguo Jixie Gongcheng/China Mechanical Engineering, 2019, 30 (18): : 2143 - 2149
  • [7] Excitation current waveform for eddy current testing on the thickness of ferromagnetic plates
    Chen, Xingle
    Lei, Yinzhao
    NDT & E INTERNATIONAL, 2014, 66 : 28 - 33
  • [8] Pulsed eddy-current nondestructive testing of ferromagnetic tubes
    Vasic, D
    Bilas, V
    Ambrus, D
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2004, 53 (04) : 1289 - 1294
  • [9] Development of differential hall sensors for Pulsed Eddy Current Testing using Gaussian pulse excitation
    Dung, Tran Thi Hoai
    Trung, Le Quang
    Kasai, Naoya
    Le, Minhhuy
    Luong, Van Su
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 379
  • [10] Estimation method of yield strength of ferromagnetic materials based on pulsed eddy current testing
    Li, Kaiyu
    Qiu, PengCheng
    Wang, Pin
    Lu, ZiXiang
    Zhang, Zhengda
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2021, 523