Aims Monitoring current of injury (COI) during left bundle branch area pacing (LBBAP) implantation is useful to evaluate lead depth. Technical aspects for recording COI amplitude have not been well studied. Our aims were to evaluate the impact of high-pass filter settings on electrogram recordings during LBBAP implantation. Methods and results Consecutive patients with successful LBBAP implantation had unipolar recordings of COI at final lead position at different high-pass filter settings (0.01-1 Hz) from the tip electrode during sensing and pacing, and from the ring electrode during sensing. Duration of saturation-induced signal loss was also measured at each filter setting. COI amplitudes were compared between lumenless and stylet-driven leads. A total of 156 patients (96 males, aged 81.4 +/- 9.6 years) were included. Higher filter settings led to significantly lower COI amplitudes. In 50 patients with COI amplitude < 10 mV, the magnitude of the drop was on average 1-1.5 mV (and up to 4 mV) between 0.05 and 0.5 Hz, meaning that cut-offs may not be used interchangeably. Saturation-induced signal loss was on average 10 s at 0.05 Hz and only 2 s with 0.5 Hz. When pacing was interrupted, the sensed COI amplitude varied (either higher or lower) by up to 4 mV, implying that it is advisable to periodically interrupt pacing to evaluate the sensed COI when reaching levels of similar to 10 mV. Lead type did not impact COI amplitude. Conclusion High-pass filters have a significant impact on electrogram characteristics at LBBAP implantation, with the 0.5 Hz settings having the most favourable profile.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Gradual development of left bundle branch current of injury during left bundle branch pacing lead implantation
    Iida, Yoji
    Inamura, Junzo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, : 1387 - 1390
  • [2] Correlations between myocardial injury current and lead performance in His bundle pacing compared with left bundle branch area pacing and right ventricular septum pacing
    Chung, Wei-Hsin
    Wu, Hung-Pin
    Wu, Mei-Yao
    Lin, Yen-Nien
    Chen, Jan-Yow
    Lin, Kuo-Hung
    Chang, Kuan-Cheng
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (06) : 1349 - 1358
  • [3] Correlations between myocardial injury current and lead performance in His bundle pacing compared with left bundle branch area pacing and right ventricular septum pacing
    Wei-Hsin Chung
    Hung-Pin Wu
    Mei-Yao Wu
    Yen-Nien Lin
    Jan-Yow Chen
    Kuo-Hung Lin
    Kuan-Cheng Chang
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1349 - 1358
  • [4] Current of injury is an indicator of lead depth and performance during left bundle branch pacing lead implantation
    Shali, Shalaimaiti
    Wu, Weiyun
    Bai, Jin
    Wang, Wei
    Qin, Shengmei
    Wang, Jingfeng
    Liang, Yixiu
    Chen, Haiyan
    Su, Yangang
    Chen, Xueying
    Ge, Junbo
    HEART RHYTHM, 2022, 19 (08) : 1281 - 1288
  • [5] Left bundle branch area pacing lead implantation using an uninterrupted monitoring of endocardial signals
    Jastrzebski, Marek
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (05) : 1055 - 1057
  • [6] Left Bundle Branch Area Pacing for LBBB Will Left Ventricular Septal Pacing Do?
    Friedman, Daniel J.
    Chelu, Mihail G.
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2024, 10 (10) : 2247 - 2249
  • [7] Left bundle branch area pacing with stylet-driven pacing leads: implantation technique
    Ga-In Yu
    Tae-Hoon Kim
    Hee Tae Yu
    Boyoung Joung
    Hui-Nam Pak
    Moon-Hyoung Lee
    International Journal of Arrhythmia, 24 (1)
  • [8] Left bundle branch pacing versus left ventricular septal pacing as a primary procedural endpoint during left bundle branch area pacing: Evaluation of two different implant strategies
    Cano, Oscar
    Jover, Pablo
    Ayala, Hebert D.
    Navarrete-Navarro, Javier
    Osca, Joaquin
    Izquierdo, Maite
    Navarro, Josep
    Martinez-Dolz, Luis
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (01) : 120 - 129
  • [9] Extraction of stylet-driven pacing lead for left bundle branch area pacing
    Bonfanti, Paolo
    Mantovani, Antonio
    Refugjati, Taulant
    Sormani, Luca
    Corrado, Giovanni
    JOURNAL OF ARRHYTHMIA, 2024, 40 (01) : 174 - 176
  • [10] Worldwide survey on implantation of and outcomes for conduction system pacing with His bundle and left bundle branch area pacing leads
    Perino, Alexander C.
    Wang, Paul J.
    Lloyd, Michael
    Zanon, Francesco
    Fujiu, Katsuhito
    Osman, Faizel
    Briongos-Figuero, Sem
    Sato, Toshiaki
    Aksu, Tolga
    Jastrzebski, Marek
    Sideris, Skevos
    Rao, Praveen
    Boczar, Krzysztof
    Xu Yuan-ning
    Wu, Michael
    Namboodiri, Narayanan
    Garcia, Rodrigue
    Kataria, Vikas
    De Pooter, Jan
    Przibille, Oliver
    Gehi, Anil K.
    Cano, Oscar
    Katsouras, Grigorios
    Cai, Binni
    Astheimer, Klaus
    Tanawuttiwat, Tanyanan
    Datino, Tomas
    Rizkallah, Jacques
    Alasti, Mohammad
    Feld, Gregory
    Barrio-Lopez, Maria Teresa
    Gilmore, Mark
    Conti, Sergio
    Yanagisawa, Satoshi
    Indik, Julia H.
    Zou, Jiangang
    Saha, Sandeep A.
    Rodriguez-Munoz, Daniel
    Chang, Kuan-Cheng
    Lebedev, Dmitry S.
    Leal, Miguel A.
    Haeberlin, Andreas
    Dal Forno, Alexander R. J.
    Orlov, Michael
    Frutos, Manuel
    Cabanas-Grandio, Pilar
    Lyne, Jonathan
    Leyva, Francisco
    Maria Tolosana, Jose
    Ollitrault, Pierre
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (07) : 1589 - 1600