Comparison of the Residual Amount of an Ophthalmic Viscosurgical Device Among Different Types of Intraocular Lens Implants in vitro

被引:0
作者
Oki, Tetsutaro [1 ]
Horiguchi, Hiroshi [1 ]
Terauchi, Ryo [1 ]
Gunji, Hisato [1 ]
Nakano, Tadashi [1 ]
机构
[1] Jikei Univ, Sch Med, Dept Ophthalmol, 3-25-8 Nishi Shinbashi, Tokyo 1058461, Japan
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
cataract surgery; intraocular lens; ophthalmic viscosurgical devices; CATARACT-SURGERY; REMOVAL TIMES; IRRIGATION/ASPIRATION; FLOW;
D O I
10.2147/OPTH.S458348
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Although ophthalmic viscosurgical devices are quite important for safe cataract surgery, currently, postoperative residual ophthalmic viscosurgical devices can cause various complications. Previously, we developed a method to visualize residual ophthalmic viscosurgical devices after irrigation/aspiration in vitro and found that the amount of residual ophthalmic viscosurgical device on a single -piece intraocular lens was greater than that on a three-piece intraocular lens. In the present study, we compared the amounts of residual ophthalmic viscosurgical device among various foldable intraocular lenses to investigate the factors that determine the quantity of residual ophthalmic viscosurgical device. Patients and Methods: Simulated cataract surgery was performed in pig eyes using an ophthalmic viscosurgical device labeled with fluorescent silica particles. After the simulated surgery procedure, the fluorescent silica attached to the intraocular lens was observed and quantified by inductively coupled plasma -atomic emission spectrometry after intraocular lens removal. The amount of residual ophthalmic viscosurgical device was compared among five representative single -piece intraocular lenses and one three-piece intraocular lens. Results: The distribution and amount of the residual ophthalmic viscosurgical device differed for each intraocular lens. The amount of silicon in the lens capsule differed among the intraocular lens types. Conclusion: The postoperative residual tendency of ophthalmic viscosurgical devices differed among various single -piece intraocular lenses. The behavior of the intraocular lenses within the capsule affected the residual tendency. The removal of ophthalmic viscosurgical device in the lens capsule should be tailored for each intraocular lens to improve efficiency.
引用
收藏
页码:1083 / 1091
页数:9
相关论文
共 21 条
[1]   Simulation of flow field during irrigation/aspiration in phacoemulsification using computational fluid dynamics [J].
Abouali, Omid ;
Bayatpour, Dariush ;
Ghaffariyeh, Alireza ;
Ahmadi, Goodarz .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08) :1530-1537
[2]   New classification of ophthalmic viscosurgical devices - 2005 [J].
Arshinoff, SA ;
Jafari, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) :2167-2171
[3]   REMOVAL OF VISCOELASTIC MATERIALS AFTER EXPERIMENTAL CATARACT-SURGERY INVITRO [J].
ASSIA, EI ;
APPLE, DJ ;
LIM, ES ;
MORGAN, RC ;
TSAI, JC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01) :3-6
[4]   Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intraocular lens material [J].
Auffarth, GU ;
Holzer, MP ;
Visessook, N ;
Apple, DJ ;
Völcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11) :2410-2414
[5]   Removal times and techniques of a viscoadaptive ophthalmic viscosurgical device [J].
Auffarth, GU ;
Holzer, MP ;
Vissesook, N ;
Apple, DJ ;
Völcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04) :879-883
[6]   In vitro behavior of ophthalmic viscosurgical devices during phacoemulsification [J].
Bissen-Miyajima, Hiroko .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (06) :1026-1031
[7]   Endophthalmitis [J].
Durand, M. L. .
CLINICAL MICROBIOLOGY AND INFECTION, 2013, 19 (03) :227-234
[8]   A primer on ocular viscosurgical devices [J].
Gerberich, Amanda J. ;
Ipema, Heather J. .
AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2021, 78 (22) :2020-2032
[9]   Quantification of residual ophthalmic viscosurgical device after irrigation/aspiration in experimental cataract surgery in vitro [J].
Gunji, Hisato ;
Ohki, Tetsutaro .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) :1324-1329
[10]  
Higashide T, 2008, CLIN OPHTHALMOL, V2, P21