Highly sensitive and selective optical detection of Staphylococcus aureus using thiol functionalized monolayer tungsten disulfide grown by chemical vapor deposition

被引:2
作者
Mia, Abdul Kaium [1 ]
Sinha, Swapnil [2 ]
Giri, P. K. [1 ,3 ]
机构
[1] Indian Inst Technol Guwahati, Ctr Nanotechnol, Gauhati 781039, India
[2] Indian Inst Technol Guwahati, BioNEST, Gauhati 781039, India
[3] Indian Inst Technol Guwahati, Dept Phys, Gauhati 781039, India
关键词
Biosensing; ssDNA Aptamers; Staphylococcus aureus; Photoluminescence; MonolayerWS2; TMDs; POLYMERASE-CHAIN-REACTION; LABEL-FREE DETECTION; SULFUR-VACANCIES; APTAMERS; MOS2;
D O I
10.1016/j.snr.2024.100214
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Monolayer tungsten disulfide (1L-WS 2 ) exhibits excellent optical properties due to its direct bandgap. The extraordinary photoluminescence (PL) emission at room temperature from CVD-grown 1L-WS 2 was utilized for the first time here as a recognition tool for detecting S. aureus bacteria with high sensitivity and selectivity. The 1L-WS 2 possesses sulfur vacancy, which has been utilized for single-standard DNA (ssDNA) aptamer immobilization via the thiol functional group. The small-sized, highly selective ssDNA aptamers identify and selectively interact with targeted S. aureus , enabling selective detection. Interestingly, the PL emission of 1L-WS 2 is strongly influenced by external charge doping. The shape of the PL emission peak of 1L-WS 2 undergoes significant changes in the presence of targeted S. aureus as a result of charge transfer originating from selective interactions between ssDNA aptamer and S. aureus, while it remains unaffected for non-targeted Escherichia coli . The ratio of the integrated intensities of trion to neutral exciton peak was used as a calibration parameter for the quantification of S. aureus concentrations. The PL analysis of 1L-WS 2 with increasing concentration of S. aureus exhibits a linear response over 10 2 CFU/mL to 10 7 CFU/ml with a lower detection limit of 2.0 CFU/mL. The proposed sensing system can identify an unknown concentration of S. aureus in human urine with 78% accuracy at a concentration of 10 5 CFU/mL. These results demonstrate the potential future generation applications of monolayer transition metal dichalcogenides in the optical biosensing of pathogenic species using suitable receptors.
引用
收藏
页数:10
相关论文
共 47 条
[41]   A WS2 nanosheet-based platform for fluorescent DNA detection via PNA-DNA hybridization [J].
Wang, Shuting ;
Zhang, Yulin ;
Ning, Yong ;
Zhang, Guo-Jun .
ANALYST, 2015, 140 (02) :434-439
[42]   CVD controlled growth of large-scale WS2 monolayers [J].
Xu, Zhuhua ;
Lv, Yanfei ;
Li, Jingzhou ;
Huang, Feng ;
Nie, Pengbo ;
Zhang, Siwei ;
Zhao, Shichao ;
Zhao, Shixi ;
Wei, Guodan .
RSC ADVANCES, 2019, 9 (51) :29628-29635
[43]   Label-free detection of Staphylococcus aureus bacteria using long-period fiber gratings with functional polyelectrolyte coatings [J].
Yang, Fan ;
Chang, Tzu-Lan ;
Liu, Tianchi ;
Wu, Di ;
Du, Henry ;
Liang, Junfeng ;
Tian, Fei .
BIOSENSORS & BIOELECTRONICS, 2019, 133 :147-153
[44]   Tuning the Conductivity Type in Monolayer WS2and MoS2by Sulfur Vacancies [J].
Yang, Jing ;
Bussolotti, Fabio ;
Kawai, Hiroyo ;
Goh, Kuan Eng Johnson .
PHYSICA STATUS SOLIDI-RAPID RESEARCH LETTERS, 2020, 14 (09)
[45]   Label-free detection of Staphylococcus aureus in skin using real-time potentiometric biosensors based on carbon nanotubes and aptamers [J].
Zelada-Guillen, Gustavo A. ;
Luis Sebastian-Avila, Jose ;
Blondeau, Pascal ;
Riu, Jordi ;
Xavier Rius, F. .
BIOSENSORS & BIOELECTRONICS, 2012, 31 (01) :226-232
[46]   Super-resolved Optical Mapping of Reactive Sulfur-Vacancies in Two-Dimensional Transition Metal Dichalcogenides [J].
Zhang, Miao ;
Lihter, Martina ;
Chen, Tzu-Heng ;
Macha, Michal ;
Rayabharam, Archith ;
Banjac, Karla ;
Zhao, Yanfei ;
Wang, Zhenyu ;
Zhang, Jing ;
Comtet, Jean ;
Aluru, Narayana R. ;
Lingenfelder, Magali ;
Kis, Andras ;
Radenovic, Aleksandra .
ACS NANO, 2021, 15 (04) :7168-7178
[47]   CRISPR-Cas13a based bacterial detection platform: Sensing pathogen Staphylococcus aureus in food samples [J].
Zhou, Jin ;
Yin, Lijuan ;
Dong, Yanan ;
Peng, Lei ;
Liu, Guozhen ;
Man, Shuli ;
Ma, Long .
ANALYTICA CHIMICA ACTA, 2020, 1127 :225-233