Highly sensitive and selective optical detection of Staphylococcus aureus using thiol functionalized monolayer tungsten disulfide grown by chemical vapor deposition

被引:0
作者
Mia, Abdul Kaium [1 ]
Sinha, Swapnil [2 ]
Giri, P. K. [1 ,3 ]
机构
[1] Indian Inst Technol Guwahati, Ctr Nanotechnol, Gauhati 781039, India
[2] Indian Inst Technol Guwahati, BioNEST, Gauhati 781039, India
[3] Indian Inst Technol Guwahati, Dept Phys, Gauhati 781039, India
关键词
Biosensing; ssDNA Aptamers; Staphylococcus aureus; Photoluminescence; MonolayerWS2; TMDs; POLYMERASE-CHAIN-REACTION; LABEL-FREE DETECTION; SULFUR-VACANCIES; APTAMERS; MOS2;
D O I
10.1016/j.snr.2024.100214
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Monolayer tungsten disulfide (1L-WS 2 ) exhibits excellent optical properties due to its direct bandgap. The extraordinary photoluminescence (PL) emission at room temperature from CVD-grown 1L-WS 2 was utilized for the first time here as a recognition tool for detecting S. aureus bacteria with high sensitivity and selectivity. The 1L-WS 2 possesses sulfur vacancy, which has been utilized for single-standard DNA (ssDNA) aptamer immobilization via the thiol functional group. The small-sized, highly selective ssDNA aptamers identify and selectively interact with targeted S. aureus , enabling selective detection. Interestingly, the PL emission of 1L-WS 2 is strongly influenced by external charge doping. The shape of the PL emission peak of 1L-WS 2 undergoes significant changes in the presence of targeted S. aureus as a result of charge transfer originating from selective interactions between ssDNA aptamer and S. aureus, while it remains unaffected for non-targeted Escherichia coli . The ratio of the integrated intensities of trion to neutral exciton peak was used as a calibration parameter for the quantification of S. aureus concentrations. The PL analysis of 1L-WS 2 with increasing concentration of S. aureus exhibits a linear response over 10 2 CFU/mL to 10 7 CFU/ml with a lower detection limit of 2.0 CFU/mL. The proposed sensing system can identify an unknown concentration of S. aureus in human urine with 78% accuracy at a concentration of 10 5 CFU/mL. These results demonstrate the potential future generation applications of monolayer transition metal dichalcogenides in the optical biosensing of pathogenic species using suitable receptors.
引用
收藏
页数:10
相关论文
共 47 条
  • [1] Adedeji W A, 2016, Ann Ib Postgrad Med, V14, P56
  • [2] Manipulating Trion and Biexciton Emissions in Monolayer WS2 by Sandwiching with Ultrathin ZnO Layers for Excitonic Light Emission Applications
    Bora, Abhilasha
    Mawlong, Larionette P. L.
    Mia, Abdul Kaium
    Giri, P. K.
    [J]. ACS APPLIED NANO MATERIALS, 2024, 7 (08) : 8612 - 8623
  • [3] Highly Suppressed Dark Current and Fast Photoresponse from Au Nanoparticle-Embedded, Si/Au/WS2 Quantum-Dot-Based, Self-Biased Schottky Photodetectors
    Bora, Abhilasha
    Mawlong, Larionette P. L.
    Giri, P. K.
    [J]. ACS APPLIED ELECTRONIC MATERIALS, 2021, 3 (11) : 4891 - 4904
  • [4] DETECTION OF STAPHYLOCOCCUS-AUREUS BY POLYMERASE CHAIN-REACTION AMPLIFICATION OF THE NUC GENE
    BRAKSTAD, OG
    AASBAKK, K
    MAELAND, JA
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (07) : 1654 - 1660
  • [5] Rational Passivation of Sulfur Vacancy Defects in Two-Dimensional Transition Metal Dichalcogenides
    Bretscher, Hope
    Li, Zhaojun
    Xiao, James
    Qiu, Diana Yuan
    Refaely-Abramson, Sivan
    Alexander-Webber, Jack A.
    Tanoh, Arelo
    Fan, Ye
    Delport, Geraud
    Williams, Cyan A.
    Stranks, Samuel D.
    Hofmann, Stephan
    Neaton, Jeffrey B.
    Louie, Steven G.
    Rao, Akshay
    [J]. ACS NANO, 2021, 15 (05) : 8780 - 8789
  • [6] Enhancing and quantifying spatial homogeneity in monolayer WS2
    Cao, Yameng
    Wood, Sebastian
    Richheimer, Filipe
    Blakesley, J.
    Young, Robert J.
    Castro, Fernando A.
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] Breast cancer biomarker detection through the photoluminescence of epitaxial monolayer MoS2 flakes
    Catalan-Gomez, Sergio
    Briones, Maria
    Cortijo-Campos, Sandra
    Garcia-Mendiola, Tania
    de Andres, Alicia
    Garg, Sourav
    Kung, Patrick
    Lorenzo, Encarnacion
    Luis Pau, Jose
    Redondo-Cubero, Andres
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [8] Ultrahigh-sensitivity label-free optical fiber biosensor based on a tapered singlemode-no core-singlemode coupler for Staphylococcus aureus detection
    Chen, Ling
    Leng, Yuan-Kui
    Liu, Bin
    Liu, Juan
    Wan, Sheng-Peng
    Wu, Tao
    Yuan, Jinhui
    Shao, Liyang
    Gu, Guoqiang
    Fu, Yong Qing
    Xu, Hengyi
    Xiong, Yonghua
    He, Xing-Dao
    Wu, Qiang
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 320
  • [9] Poly-L ysine-functionalized magnetic beads combined with polymerase chain reaction for the detection of Staphylococcus aureus and Escherichia coli O157:H7 in milk
    Deng, Mei
    Wang, Yutong
    Chen, Guanhua
    Liu, Ju
    Wang, Zhengzheng
    Xu, Hengyi
    [J]. JOURNAL OF DAIRY SCIENCE, 2021, 104 (12) : 12342 - 12352
  • [10] Response to NO2 and other gases of resistive chemically exfoliated MoS2-based gas sensors
    Donarelli, M.
    Prezioso, S.
    Perrozzi, F.
    Bisti, F.
    Nardone, M.
    Giancaterini, L.
    Cantalini, C.
    Ottaviano, L.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 : 602 - 613