Comparative evaluation of self-pressurized Air-Q® and Proseal™ LMA® in patients undergoing elective surgery under general anaesthesia: A randomized clinical trial

被引:1
作者
Rana, Savita [1 ]
Anand, Lakesh Kumar [2 ]
Singh, Manpreet [1 ]
Kapoor, Dheeraj [1 ]
Gupta, Deepika [1 ]
Kaur, Harpreet [1 ]
机构
[1] Govt Med Coll & Hosp, Dept Anaesthesia & Intens Care, Sect 32, Chandigarh 160032, India
[2] Maharishi Markandeshwar Inst Med Sci & Res, Dept Anaesthesia, Ambala, Haryana, India
关键词
Air-Q SP; oropharyngeal leak pressure; Proseal LMA; INTUBATING LARYNGEAL AIRWAY; MASK AIRWAY; TRACHEAL INTUBATION; VENTILATION; POSITION;
D O I
10.4103/joacp.joacp_248_22
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background and Aims: Intra-cuff pressure of Air-Q self-pressurized laryngeal airways (Air-Q SP) balances airway pressure and adapts to patient's pharyngeal and periglottic structures, thus improves oropharyngeal leak pressure (OLP).This study was performed to compare efficacy of Air-Q SP with Proseal laryngeal mask airway (PLMA) in patients undergoing elective surgery. Material and Methods: The study design was prospective, randomized and controlled. Ninety patients were randomly assigned to Air-Q SP or PLMA group. All patients were premedicated and shifted to operation theatre. Monitoring was instituted. After securing IV-line, induction with inj. Morphine + Propofol, relaxation with inj. Vecuronium was done. Supraglottic was inserted according to group allocation. Outcome measures were OLP, fibreoptic view of larynx, success rate, device insertion parameters, haemodynamic and respiratory parameters and post-operative laryngopharyngeal complications. Neostigmine + glycopyrrolate were given, device was extubated. Results: All supraglottic airway devices (SADs) were successfully placed in two attempts. The mean initial OLP, OLP at 10 minutes, and device insertion time were significantly lower in Air-Q SP group. Fiber-optic laryngeal view grading was significantly better with Air-Q SP. No significant difference was observed with respect to rate of successful insertion in first attempt, ease of insertion, and manipulations required. The hemodynamic/respiratory parameters and post-operative sore throat in the two both groups were similar. Conclusions: Proseal LMA has a higher OLP than Air-Q SP but average insertion time was better, and fiber-optic grading of laryngeal view was shorter with Air-Q SP. However, Air-Q SP and Proseal LMA were both effective for lung ventilation.
引用
收藏
页码:336 / 343
页数:8
相关论文
共 21 条
  • [1] Aly AA., 2019, Ain Shams J Anaesthesiol, V10, P149
  • [2] Anand Lakesh K, 2016, Acta Anaesthesiol Taiwan, V54, P44, DOI 10.1016/j.aat.2016.03.001
  • [3] Supraglottic airway devices: recent advances
    Cook, Tim
    Howes, Ben
    [J]. BJA EDUCATION, 2011, 11 (02) : 56 - 61
  • [4] Cook TM., 2005, Can J Anesth, V57, P128
  • [5] The air-Q® intubating laryngeal airway vs the LMA-ProSeal™: a prospective, randomised trial of airway seal pressure
    Galgon, R. E.
    Schroeder, K. M.
    Han, S.
    Andrei, A.
    Joffe, A. M.
    [J]. ANAESTHESIA, 2011, 66 (12) : 1093 - 1100
  • [6] Ha SH, 2018, CAN J ANESTH, V65, P543, DOI 10.1007/s12630-018-1082-6
  • [7] Comparison of laryngeal mask airway supremeTM as non-inflatable cuff device and self-pressurized air-QTM in children: Randomized controlled non-inferiority study
    Hwang, Jagyung
    Hong, Boohwi
    Kim, Yoon-Hee
    Lee, Won Hyung
    Jo, Yumin
    Youn, SooKyoung
    Lim, Chae Seong
    [J]. MEDICINE, 2019, 98 (10)
  • [8] A randomised comparison of the self-pressurised air-Q™ intubating laryngeal airway with the LMA Unique™ in children
    Jagannathan, N.
    Sohn, L. E.
    Sawardekar, A.
    Shah, R.
    Ryan, K.
    Jagannathan, R.
    Anderson, K.
    [J]. ANAESTHESIA, 2012, 67 (09) : 973 - 979
  • [9] A randomized crossover comparison between the Laryngeal Mask Airway-Unique™ and the air-Q Intubating Laryngeal Airway in children*
    Jagannathan, Narasimhan
    Sohn, Lisa E.
    Mankoo, Ravinder
    Langen, Kenneth E.
    Mandler, Tessa
    [J]. PEDIATRIC ANESTHESIA, 2012, 22 (02) : 161 - 167
  • [10] Prospective evaluation of the self-pressurized air-Q intubating laryngeal airway in children
    Jagannathan, Narasimhan
    Sohn, Lisa E.
    Mankoo, Ravinder
    Langen, Kenneth E.
    Roth, Andrew G.
    Hall, Steven C.
    [J]. PEDIATRIC ANESTHESIA, 2011, 21 (06) : 673 - 680