Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm

被引:2
作者
Kim, Jun Seong [1 ]
Park, So Hyun [1 ]
Park, Suyoung [1 ]
Hwang, Jung Han [1 ]
Kim, Jeong Ho [1 ]
Pak, Seong Yong [2 ,4 ]
Lee, Kihyun [1 ]
Schmidt, Bernhard [3 ]
机构
[1] Gachon Univ, Coll Med, Gil Med Ctr, Dept Radiol, 21 Namdong Daero 774 Beon Gil, Incheon 21565, South Korea
[2] Univ Ulsan, Asan Med Inst Convergence Sci & Technol, Asan Med Ctr, Dept Biomed Engn,Coll Med, Seoul, South Korea
[3] Siemens Healthineers, Forchheim, Germany
[4] Siemens Healthineers, Seoul, South Korea
来源
JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY | 2022年 / 83卷 / 05期
关键词
Computed Tomography; X-Ray; Peripheral Arterial Disease; Lower Extremity; VENOUS CONTAMINATION; ENERGY;
D O I
10.3348/jksr.2021.0191
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Peripheral arterial disease (PAD) is common in elderly patients. Lower -extremity CT angiography (LE-CTA) can be useful for detecting PAD and planning its treatment. PAD can also be accurately evaluated on reconstructed monoenergetic images (MEIs) from low kiloelectron volt (keV) to high keV images using dualenergy CT. Low keV images generally provide higher contrast than high keV images but also feature more severe image noise. The noise -reduced virtual MEI reconstruction algorithm, called the Mono+ technique, was recently introduced to overcome such image noise. Therefore, this pictorial review aimed to present the imaging findings of PAD on LE-CTA and compare low and high keV images with those subjected to the Mono+ technique. We found that, in many cases, the overall and segmental image qualities were better and metal artifacts and venous contamination were decreased in the high keV images.
引用
收藏
页码:1032 / 1045
页数:14
相关论文
共 18 条
  • [1] Aboyans V, 2018, Rev Esp Cardiol (Engl Ed), V71, P111, DOI [10.1016/j.rec.2017.12.014, DOI 10.1016/J.REC.2017.12.014]
  • [2] 2017 ESC Guidelines on the Diagnosis and Treatment of Peripheral Arterial Diseases, in collaboration with the European Society for Vascular Surgery (ESVS)
    Aboyans, Victor
    Ricco, Jean-Baptiste
    Bartelink, Marie-Louise E. L.
    Bjorck, Martin
    Brodmann, Marianne
    Cohnert, Tina
    Collet, Jean-Philippe
    Czerny, Martin
    De Carlo, Marco
    Debus, Sebastian
    Espinola-Klein, Christine
    Kahan, Thomas
    Kownator, Serge
    Mazzolai, Lucia
    Naylor, A. Ross
    Roffi, Marco
    Roether, Joachim
    Sprynger, Muriel
    Tendera, Michal
    Tepe, Gunnar
    Venermo, Maarit
    Vlachopoulos, Charalambos
    Desormais, Ileana
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 (09) : 763 - +
  • [3] Virtual mono-energetic images and iterative image reconstruction: abdominal vessel imaging in the era of spectral detector CT
    Al-Baldawi, Y.
    Hokamp, N. Grosse
    Haneder, S.
    Steinhauser, S.
    Puesken, M.
    Persigehl, T.
    Maintz, D.
    Wybranski, C.
    [J]. CLINICAL RADIOLOGY, 2020, 75 (08) : 641.e9 - 641.e18
  • [4] A Factor Increasing Venous Contamination on Bolus Chase Three-dimensional Magnetic Resonance Imaging: Charcot Neuroarthropathy
    Cildag, Mehmet B.
    Ertugrul, Mustafa B.
    Koseoglu, Omer F. K.
    Armstrong, David G.
    [J]. JOURNAL OF CLINICAL IMAGING SCIENCE, 2018, 8
  • [5] Epidemiology of Peripheral Artery Disease
    Criqui, Michael H.
    Aboyans, Victor
    [J]. CIRCULATION RESEARCH, 2015, 116 (09) : 1509 - 1526
  • [6] Comparison of global estimates of prevalence and risk factors for peripheral artery disease in 2000 and 2010: a systematic review and analysis
    Fowkes, F. Gerald R.
    Rudan, Diana
    Rudan, Igor
    Aboyans, Victor
    Denenberg, Julie O.
    McDermott, Mary M.
    Norman, Paul E.
    Sampson, Uchechukwe K. A.
    Williams, Linda J.
    Mensah, George A.
    Criqui, Michael H.
    [J]. LANCET, 2013, 382 (9901) : 1329 - 1340
  • [7] Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media
    Grant, Katharine L.
    Flohr, Thomas G.
    Krauss, Bernhard
    Sedlmair, Martin
    Thomas, Christoph
    Schmidt, Bernhard
    [J]. INVESTIGATIVE RADIOLOGY, 2014, 49 (09) : 586 - 592
  • [8] CT Angiography in the Lower Extremity Peripheral Artery Disease Feasibility of an Ultra-Low Volume Contrast Media Protocol
    Horehledova, Barbora
    Mihl, Casper
    Milanese, Gianluca
    Brans, Rutger
    Eijsvoogel, Nienke G.
    Hendriks, Babs M. F.
    Wildberger, Joachim E.
    Das, Marco
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (11) : 1751 - 1764
  • [9] Advanced virtual monoenergetic imaging algorithm for lower extremity computed tomography angiography: effects on image quality, artifacts, and peripheral arterial disease evaluation
    Hwang, Jung Han
    Kang, Jin Mo
    Park, Suyoung
    Park, So Hyun
    Kim, Jeong Ho
    Lee, Ki Hyun
    Shin, Ji Hoon
    Pak, Seong Yong
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2023, 29 (01): : 175 - 182
  • [10] Comparison of standard-dose and half-dose dual-source abdominopelvic CT scans for evaluation of acute abdominal pain
    Lee, Ki Hyun
    Shim, Young Sup
    Park, So Hyun
    Park, Seong Ho
    Choi, Seung Joon
    Pak, Seong Yong
    Cheong, Hyunhee
    [J]. ACTA RADIOLOGICA, 2019, 60 (08) : 946 - 954