Non-enzymatic disposable paper sensor for electrochemical detection of creatinine

被引:6
作者
Manikandan, Ramalingam [1 ,2 ]
Yoon, Jang-Hee [3 ]
Lee, Jaewon [4 ]
Chang, Seung-Cheol [1 ]
机构
[1] Pusan Natl Univ, Coll Nanosci & Nanotechnol, Dept Cogno Mechatron Engn, Busan 46241, South Korea
[2] Pusan Natl Univ, Engn Res Ctr Color Modulated Extrasensory Percept, Busan 46241, South Korea
[3] Korea Basic Sci Inst, Busan Ctr, Busan 46742, South Korea
[4] Pusan Natl Univ, Coll Pharm, Dept Pharm, Busan 46241, South Korea
基金
新加坡国家研究基金会;
关键词
Creatinine; Kidney disease; Paper-based analytical device; Electrochemical activation; Stripping voltammetry; Blood serum and urine;
D O I
10.1016/j.microc.2024.111114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selective detection of creatinine (Ctn) is crucial for the clinical diagnosis of early-stage kidney dysfunction. A non-enzymatic electrochemical method for a highly selective and sensitive detection of Ctn in blood serum and urine samples was developed using an electrochemically activated carbon-coated paper-based analytical device (ePAD*). During activation, the growth of stable carboxyl (C = O, COOH) groups on the edge planes of the carbon surface was observed. The prepared ePAD* was characterized using various microscopic, spectroscopic, and electrochemical techniques. The ePAD* was utilized as a medium exchanger, and the voltammetric response of Ctn detection in the linear concentration from 0.03 to 45 mM with a detection limit of 5.41 mu M was achieved. In addition, the selective detection of Ctn in the presence of potential interferences (i.e., uric acid, ascorbic acid, ammonia, and urea) was examined. The examination revealed a remarkable selectivity toward Ctn detection. Real-time detection of Ctn in blood serum and urine samples was performed. The results were correlated with the classical Jaffe <acute accent> colorimetric method. Our ePAD* exhibited a better electrochemical response. Thus, it is a highly potential diagnostic method for further development as a rapid and precise detection platform for point-of-care (POC) devices for examining patients with kidney disease.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Development of a Disposable, Paper-Based Blood Urea Sensor for Point-of-Care Health Monitoring
    Bose, Asmita
    Biswas, Karabi
    IEEE SENSORS JOURNAL, 2022, 22 (17) : 17275 - 17282
  • [42] Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics
    Saddique, Zohaib
    Siddique, Tazeen
    Shehzadi, Arooj
    Ul-Ain, Qurat
    Ali, Asghar
    Iqbal, Naseer
    Mujahid, Adnan
    Afzal, Adeel
    COMPOSITES COMMUNICATIONS, 2023, 42
  • [43] Conception and characterization of moleculary imprinted polymers nanofibers of poly(ethylene-co-vinyl alcohol) and their use as membrane in electrochemical sensor for creatinine detection
    Betatache, A.
    Chateaux, J. F.
    Jaffrezic-Renault, Nicole
    JOURNAL OF NEW TECHNOLOGY AND MATERIALS, 2018, 8 (01) : 68 - 73
  • [44] In vitro non-enzymatic ribation reduces post-yield strain accommodation in cortical bone
    Willett, Thomas L.
    Sutty, Sibi
    Gaspar, Anne
    Avery, Nick
    Grynpas, Marc
    BONE, 2013, 52 (02) : 611 - 622
  • [45] An electrochemical sensor for creatinine based on carbon nanotubes/folic acid/silver nanoparticles modified electrode
    Fekry, A. M.
    Abdel-Gawad, S. A.
    Tammam, R. H.
    Zayed, M. A.
    MEASUREMENT, 2020, 163
  • [46] New Disposable Electrochemical Paper-based Microfluidic Device with Multiplexed Electrodes for Biomarkers Determination in Urine Sample
    Fava, Elson Luiz
    do Prado, Thiago Martimiano
    Silva, Tiago Almeida
    de Moraes, Fernando Cruz
    Faria, Ronaldo Censi
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2020, 32 (05) : 1075 - 1083
  • [47] Effect of serum creatinine difference between the Jaffe and the enzymatic method on kidney disease detection and staging
    Boss, Kristina
    Stolpe, Susanne
    Mueller, Andre
    Wagner, Bernd
    Wichert, Marc
    Assert, Roland
    Volbracht, Lothar
    Stang, Andreas
    Kowall, Bernd
    Kribben, Andreas
    CLINICAL KIDNEY JOURNAL, 2023, 16 (11) : 2147 - 2155
  • [48] CuAg electrode for creatinine microfluidic fuel cell based self-powered electrochemical sensor
    Garcia-Barajas, M.
    Trejo-Dominguez, A. M.
    Ledesma-Garcia, J.
    Arriaga, L. G.
    Contreras, L. Alvarez
    Galindo-de-la-Rosa, J.
    Arjona, N.
    Guerra-Balcazar, M.
    2019 19TH INTERNATIONAL CONFERENCE ON MICRO AND NANOTECHNOLOGY FOR POWER GENERATION AND ENERGY CONVERSION APPLICATIONS (POWERMEMS), 2020,
  • [49] An electrochemical composite sensor for phenol detection in waste water
    Aliabadi, Maryam Hosseini
    Esmaeili, Naser
    Jahromi, Hamideh Samari
    APPLIED NANOSCIENCE, 2020, 10 (02) : 597 - 609
  • [50] Electrochemically grown polymethylene blue nanofilm on copper-carbon nanofiber nanocomposite: An electrochemical sensor for creatinine
    Pandey, Indu
    Bairagi, Pallab Kumar
    Verma, Nishith
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 277 : 562 - 570