Space Electromagnetic Optimization of Three-Coil WPT for Online Monitoring Equipment of High-Voltage Transmission Lines

被引:0
|
作者
Zhang, Xian [1 ]
Zhou, Yitong [1 ]
Zhou, Wei [2 ]
Dai, Zhongyu [1 ]
Li, Musong [1 ]
机构
[1] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equipm, Key Lab Electromagnet Field & Elect Apparat Reliab, Tianjin 300130, Peoples R China
[2] Northwest Elect Power Design Inst Co Ltd, China Power Engn Consulting Grp, Xian 710075, Peoples R China
关键词
Coils; Relays; Electromagnetics; Vectors; Safety; Monitoring; Couplings; Energy confinement; energy flow; optimization study; three-coil system; wireless power transmission (WPT); POWER TRANSFER SYSTEM; AC-AC CONVERTER;
D O I
10.1109/TEMC.2024.3417242
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the context of a smart grid, sensors act as real-time monitoring devices. They enable the continuous assessment of the performance index for high-voltage transmission lines. Compared with the traditional lithium battery energy supply system, wireless power transmission (WPT) systems not only ensure the safety but also reduce the maintenance schedule. In the process of energy transmission, traditional insulator-clamped WPT systems are susceptible to interference from metal connectors. Moreover, electromagnetic energy leakage can pose threats to the safety of personnel working with charged equipment and the stable operation of nearby conductive sensing devices. This study analyzes the general principles of energy flow in multicoil WPT systems based on the Poynting's theorem. We introduce the energy contraction coefficients to analyze the distribution of electromagnetic energy in the three-coil systems Achieving energy confinement in the system by adding the relay coils. Combined with an engineering background, we establish constraints and optimize the relay coil's radius and position. We clarify the relationship between relay coil parameters and system energy confinement. Through simulations and experiments, it is shown that with a constant system output power, the optimized three-coil systems improve the energy contraction coefficient by 20.9% compared to the initial two-coil system and increase the magnetic flux density contraction coefficient by 19.4%. This effectively enhances the stability of energy transfer and the safety of the external electromagnetic environment in insulator-clamped WPT systems.
引用
收藏
页码:1621 / 1632
页数:12
相关论文
共 41 条
  • [31] Study on Induction Electric Power Supply from the High Voltage Transmission Lines for the Wireless Intelligent Monitoring Equipment
    Zhao, Yalei
    Luo, Jian
    Hou, Guandong
    Huang, Renke
    2017 IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, COMMUNICATIONS AND COMPUTING (ICSPCC), 2017,
  • [32] Electromagnetic Impact of Overhead High-Voltage Lines during Power Transmission on Buried Signaling Cables of the Traffic Control Systems in Modernized Railway Lines
    Wrobel, Zofia
    Ziemba, Robert
    Markowska, Renata
    Mielnik, Ryszard
    ENERGIES, 2024, 17 (11)
  • [33] The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing PR China
    Qin, Qi-zhong
    Chen, Yu
    Fu, Ting-ting
    Ding, Li
    Han, Ling-li
    Li, Jian-chao
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2012, 184 (03) : 1533 - 1540
  • [34] Noncontact Operation-State Monitoring Technology Based on Magnetic-Field Sensing for Overhead High-Voltage Transmission Lines
    Sun, Xun
    Huang, Qi
    Hou, Yunhe
    Jiang, Lijun
    Pong, Philips
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [35] Noncontact Operation-State Monitoring Technology Based on Magnetic-Field Sensing for Overhead High-Voltage Transmission Lines
    Sun, Xu
    Huang, Qi
    Hou, Yunhe
    Jiang, Lijun
    Pong, Philip W. T.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) : 2145 - 2153
  • [36] A COMPUTING MODEL AND ITS EXPERIMENTAL TESTING FOR AN EVALUATION OF ELECTROMAGNETIC INTERFERENCES CREATED BY INTERFERING CIRCUITS ON TRANSMISSION OR HIGH-VOLTAGE LINES ABOVE A DISSIPATIVE GROUND
    UMBERT, A
    FONTAINE, J
    PLUMEY, JP
    SPACE SCIENCE REVIEWS, 1983, 35 (01) : 49 - 58
  • [37] Design of a galvanic monitoring module for high-voltage overhead transmission lines based on the fusion of multi-mode spatial distance weights
    Yuan J.
    Pan G.
    Xie J.
    Chen X.
    Guo J.
    Liu X.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (24): : 173 - 179
  • [38] The monitoring results of electromagnetic radiation of 110-kV high-voltage lines in one urban location in Chongqing P.R. China
    Qi-zhong Qin
    Yu Chen
    Ting-ting Fu
    Li Ding
    Ling-li Han
    Jian-chao Li
    Environmental Monitoring and Assessment, 2012, 184 : 1533 - 1540
  • [39] Wind-driven suspended triboelectric-electromagnetic hybrid generator with vibration elimination for environmental monitoring in the high-voltage power transmission line
    Gao, Sihang
    Luo, Xiaoting
    Wei, Hao
    Wang, Rui
    Chen, Xiaolei
    Zhang, Jiajia
    NANO ENERGY, 2024, 128
  • [40] Real-time sag monitoring system for high-voltage overhead transmission lines based on power-line carrier signal behavior
    de Villiers, Wernich
    Cloete, Johannes Hendrik
    Wedepohl, L. Martin
    Burger, Arthur
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) : 389 - 395