The pressure dependence of the experimentally-determined line intensity and continuum absorption of pure CO2 in the 1.6μm region

被引:0
作者
Birk, M. [1 ]
Roeske, C. [1 ]
Wagner, G. [1 ]
机构
[1] German Aerosp Ctr DLR, Remote Sensing Technol Inst, D-82234 Wessling, Germany
关键词
Carbon dioxide; Pressure-dependent line intensity; Continuum; High accuracy Fourier transform measurements; atmospheric CO2 measurements; COLLISION-INDUCED ABSORPTION; 2ND VIRIAL-COEFFICIENTS; CARBON-DIOXIDE; PARAMETERS; MIXTURES; NITROGEN; ARGON; WATER; SHAPE; HCL;
D O I
10.1016/j.jqsrt.2024.109055
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fourier-transform measurements of pure CO 2 spectra in the 1.6 mu m region covering bands from the ground state to the 30011, 30012, 30013, and 30014 states at ambient temperature and 212 K with pressures up to 1 atm have been recorded. The measured spectra have been multispectrum-fitted with the Hartmann-Tran model with first order line-mixing taken into account. In the fits, a linear decrease of the line intensities with increasing pressure was introduced. From the fitted baselines, the self-continuum, which complements the contribution of the local lines within +/- 25 cm -1 , was determined for the two strongest bands, 30012-00001 and 30013-00001. The depleted intensity was found to be transferred to the continuum for both temperatures. The intensity in the continuum at 1 atm was about 1 % of the total band intensity for ambient temperature and about 3 % at 212 K. For both temperatures, the average depleted intensity/continuum area was found in excellent agreement with values estimated from the second virial coefficient. From these results, a new spectroscopic database with pure CO 2 line profile parameters was produced, with systematic line intensity uncertainties well below 0.1 %. Retrieval simulations for the CO 2 1.6 mu m and 2 mu m bands measurements, planned with the future CO2M mission, similar to the OCO mission, were carried out to assess the impact of intensity depletion and continuum. The impact of the continuum was larger than that of the depletion and larger for the 2 mu m band than for the 1.6 mu m band, with a substantial column error of 2 % for the 2 mu m band when omitting both, depletion and continuum. The findings regarding pressure-dependent intensity and continuum may be applicable to other in -band continua showing similarity to the monomer band in shape and position. The new results may increase the knowledge on the physical nature of continua.
引用
收藏
页数:20
相关论文
共 37 条
  • [31] Infrared absorption by pure CO2 near 3340 cm-1: Measurements and analysis of collisional coefficients and line-mixing effects at subatmospheric pressures
    Daneshvar, L.
    Foeldes, T.
    Buldyreva, J.
    Auwera, J. Vander
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2014, 149 : 258 - 274
  • [32] Radiometric comparison of 1.6-μm CO2 absorption band of Greenhouse Gases Observing Satellite (GOSAT) TANSO-FTS with Suomi-NPP VIIRS SWIR band
    Uprety, Sirish
    Cao, Changyong
    Journal of Atmospheric and Oceanic Technology, 2016, 33 (07): : 1443 - 1453
  • [33] Theoretical study of threshold intensity dependence on gas pressure in the breakdown of helium by CO2 laser radiation: Influence of preionization mechanism
    Gamal, Yosr E. E. -D.
    Metwally, Ehab. S.
    Nassef, O. Aied
    PHYSICS OF PLASMAS, 2022, 29 (07)
  • [34] The absorption spectrum of 13CH4 in the region of the 2ν3 band at 1.66 μm: Empirical line lists and temperature dependence
    Campargue, A.
    Segovia, J. Lopez
    Beguier, S.
    Kassi, S.
    Mondelain, D.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 152 : 140 - 148
  • [35] Efficient representation of the absorption line blackbody distribution function for H2O, CO2, and CO at variable temperature, mole fraction, and total pressure
    Pearson, John T.
    Webb, Brent W.
    Solovjov, Vladimir P.
    Ma, Jiefu
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2014, 138 : 82 - 96
  • [36] Measurements of high-pressure CO2 absorption near 2.0 μm and implications on tunable diode laser sensor design
    Rieker, G. B.
    Jeffries, J. B.
    Hanson, R. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 94 (01): : 51 - 63
  • [37] High-temperature absorption line shape parameters for CO2 in the 6800-7000 cm-1 region from dual frequency comb measurements up to 1000 K
    Cole, Ryan K.
    Hoghooghi, Nazanin
    Drouin, Brian J.
    Rieker, Gregory B.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2021, 276