A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid

被引:1
|
作者
Stoikov, Dmitry [1 ]
Shafigullina, Insiya [1 ]
Shurpik, Dmitry [1 ]
Stoikov, Ivan [1 ]
Evtugyn, Gennady [1 ,2 ]
机构
[1] Kazan Fed Univ, AM Butlerov Chem Inst, 18 Kremlevskaya St, Kazan 420008, Russia
[2] Ural Fed Univ, Chem Technol Inst, Analyt Chem Dept, 19 Mira St, Ekaterinburg 620002, Russia
基金
俄罗斯科学基金会;
关键词
flow-through cell; chronoamperometry; uricase biosensor; ferrocene; pillarquinone; uricase determination; hydrogen peroxide determination; HOST-GUEST COMPLEXATION; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL DETERMINATION; NANOCOMPOSITE; OXIDE; NANOSTRUCTURES;
D O I
10.3390/chemosensors12060098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simple and reliable electrochemical sensors are highly demanded in medicine and pharmacy for the fast determination of metabolites and biomarkers of diseases. In this work, a flow-through biosensor system was developed on the base of a screen-printed carbon electrode modified with pillar[3]arene[2]quinone and ferrocene implemented in carbon black. The modification was performed in a single step and resulted in the formation of a stable layer with good operation characteristics. Uricase was immobilized on the inner walls of a replaceable reactor by carbodiimide binding. A flow-through cell was manufactured by 3D printing from poly(lactic acid). The flow-through system was first optimized on the hydrogen peroxide assay and then used for the determination of 1 nM-0.1 mM uric acid (limit of detection 0.3 nM, 20 measurements per hour). Implementation of ferrocene resulted in a synergetic increase in the cathodic current of H2O2 reduction measured by flow switching in chronoamperometric mode. The developed system was tested on the determination of uric acid in artificial urine and Ringer-Locke solution and showed a recovery rate of 96-112%. In addition, the possibility of determination of H2O2 in commercial disinfectants was shown. Easy assembly, fast and reliable signal and low consumption of the reagents make the system developed attractive for routine clinical analysis of metabolites.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Enzyme Biosensor Based on 3D-Printed Flow-Through Reactor Modified with Thiacalixarene-Functionalized Oligo (Lactic Acids)
    Stoikov, Dmitry
    Kappo, Dominika
    Ivanov, Alexey
    Gorbachuk, Vladimir
    Mostovaya, Olga
    Padnya, Pavel
    Stoikov, Ivan
    Evtugyn, Gennady
    BIOSENSORS-BASEL, 2025, 15 (02):
  • [42] Enzyme-free and wide-range portable colorimetric sensing system for uric acid and hydrogen peroxide based on copper nanoparticles
    Ma, Chiyu
    Kong, Liubing
    Sun, Xianyou
    Zhang, Yanchi
    Wang, Xinyi
    Wei, Xinwei
    Wan, Hao
    Wang, Ping
    TALANTA, 2023, 255
  • [43] Electrochemical Hydrogen Peroxide Generation and Activation Using a Dual-Cathode Flow-Through Treatment System: Enhanced Selectivity for Contaminant Removal by Electrostatic Repulsion
    Duan, Yanghua
    Sedlak, David L.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (31) : 14042 - 14051
  • [44] A peroxidase-tetrathiafulvalene biosensor based on self-assembled monolayer modified Au electrodes for the flow-injection determination of hydrogen peroxide
    Campuzano, S
    Pedrero, M
    Pingarrón, JA
    TALANTA, 2005, 66 (05) : 1310 - 1319
  • [45] Electrochemical Biosensor Based on HRP/Ti3C2/Nafion Film for Determination of Hydrogen Peroxide in Serum Samples of Patients with Acute Myocardial Infarction
    Xu, Wei
    Sakran, Marwan
    Fei, Jianwen
    Li, Xiaoyun
    Weng, Chenyuan
    Yang, Wei
    Zhu, Guomin
    Zhu, Wanying
    Zhou, Xuemin
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (06) : 2767 - 2773
  • [46] Simultaneous determination of ascorbic acid, dopamine, uric acid and hydrogen peroxide based on co-immobilization of PEDOT and FAD using multi-walled carbon nanotubes
    Lin, Kuo Chiang
    Huang, Jia Yan
    Chen, Shen Ming
    ANALYTICAL METHODS, 2014, 6 (20) : 8321 - 8327
  • [47] A multicommuted flow system for fast screening/sequential spectrophotometric determination of dichromate, salicylic acid, hydrogen peroxide and starch in milk samples
    de Souza, Gustavo Campelo S.
    Bezerra da Silva, Paulo A.
    Leoterio, Dilmo Marques da S.
    Silveira Paim, Ana Paula
    Lavorante, Andre F.
    FOOD CONTROL, 2014, 46 : 127 - 135
  • [48] Flow-injection determination of trace hydrogen peroxide or glucose utilizing an amperometric biosensor based on glucose oxidase bound to a reticulated vitreous carbon electrode
    Khayyami, M
    Johansson, G
    Kriz, D
    Xie, B
    Larsson, PO
    Danielsson, B
    TALANTA, 1996, 43 (06) : 957 - 962
  • [49] Quantitative determination of uric acid using paper-based biosensor modified with graphene oxide and 5-amino-1,3,4-thiadiazole-2-thiol
    Chang, Yaw-Jen
    Lee, Ming-Che
    Chien, You-Chiuan
    SLAS TECHNOLOGY, 2022, 27 (01): : 54 - 62
  • [50] A simple and sensitive fluorescence based biosensor for the determination of uric acid using H2O2-sensitive quantum dots/dual enzymes
    Azmi, Nur Ellina
    Ramli, Noor Izaanin
    Abdullah, Jaafar
    Hamid, Mohammad Azmi Abdul
    Sidek, Hamidah
    Abd Rahman, Samsulida
    Ariffin, Nurhayati
    Yusof, Nor Azah
    BIOSENSORS & BIOELECTRONICS, 2015, 67 : 129 - 133