A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid

被引:1
|
作者
Stoikov, Dmitry [1 ]
Shafigullina, Insiya [1 ]
Shurpik, Dmitry [1 ]
Stoikov, Ivan [1 ]
Evtugyn, Gennady [1 ,2 ]
机构
[1] Kazan Fed Univ, AM Butlerov Chem Inst, 18 Kremlevskaya St, Kazan 420008, Russia
[2] Ural Fed Univ, Chem Technol Inst, Analyt Chem Dept, 19 Mira St, Ekaterinburg 620002, Russia
基金
俄罗斯科学基金会;
关键词
flow-through cell; chronoamperometry; uricase biosensor; ferrocene; pillarquinone; uricase determination; hydrogen peroxide determination; HOST-GUEST COMPLEXATION; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL DETERMINATION; NANOCOMPOSITE; OXIDE; NANOSTRUCTURES;
D O I
10.3390/chemosensors12060098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Simple and reliable electrochemical sensors are highly demanded in medicine and pharmacy for the fast determination of metabolites and biomarkers of diseases. In this work, a flow-through biosensor system was developed on the base of a screen-printed carbon electrode modified with pillar[3]arene[2]quinone and ferrocene implemented in carbon black. The modification was performed in a single step and resulted in the formation of a stable layer with good operation characteristics. Uricase was immobilized on the inner walls of a replaceable reactor by carbodiimide binding. A flow-through cell was manufactured by 3D printing from poly(lactic acid). The flow-through system was first optimized on the hydrogen peroxide assay and then used for the determination of 1 nM-0.1 mM uric acid (limit of detection 0.3 nM, 20 measurements per hour). Implementation of ferrocene resulted in a synergetic increase in the cathodic current of H2O2 reduction measured by flow switching in chronoamperometric mode. The developed system was tested on the determination of uric acid in artificial urine and Ringer-Locke solution and showed a recovery rate of 96-112%. In addition, the possibility of determination of H2O2 in commercial disinfectants was shown. Easy assembly, fast and reliable signal and low consumption of the reagents make the system developed attractive for routine clinical analysis of metabolites.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Fabrication of Multifunctional Biosensor for the Determination of Hydrogen Peroxide, Dopamine and Uric Acid
    Tsai, Tsung-Hsuan
    Huang, Yun-Chin
    Chen, Shen-Ming
    Ali, M. Ajmal
    AlHemaid, M. A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6456 - 6468
  • [2] Flow-Through Amperometric Biosensor System Based on Functionalized Aryl Derivative of Phenothiazine and PAMAM-Calix-Dendrimers for the Determination of Uric Acid
    Stoikov, Dmitry
    Ivanov, Alexey
    Shafigullina, Insiya
    Gavrikova, Milena
    Padnya, Pavel
    Shiabiev, Igor
    Stoikov, Ivan
    Evtugyn, Gennady
    BIOSENSORS-BASEL, 2024, 14 (03):
  • [3] CHEMILUMINESCENCE FLOW-THROUGH BIOSENSOR FOR HYDROGEN PEROXIDE BASED ON ENHANCED HRP ACTIVITY BY GOLD NANOPARTICLES
    Lan, Dan
    Li, Baoxin
    BIOLUMINESCENCE AND CHEMILUMINESCENCE, 2009, : 217 - 220
  • [4] Chemiluminescence flow-through biosensor for hydrogen peroxide based on enhanced HRP activity by Au nanoparticles
    Lan, D.
    Li, B.
    LUMINESCENCE, 2008, 23 (02) : 78 - 78
  • [5] Flow-Through Electrochemical Biosensor with a Replaceable Enzyme Reactor and Screen-Printed Electrode for the Determination of Uric Acid and Tyrosine
    Stoikov, Dmitrii
    Ivanov, Alexey
    Shurpik, Dmitriy
    Stoikov, Ivan
    Evtugyn, Gennady
    ANALYTICAL LETTERS, 2022, 55 (08) : 1281 - 1295
  • [6] A REAGENTLESS AMPEROMETRIC BIOSENSOR FOR HYDROGEN-PEROXIDE DETERMINATION BASED ON ASPARAGUS TISSUE AND FERROCENE MEDIATION
    OUNGPIPAT, W
    ALEXANDER, PW
    SOUTHWELLKEELY, P
    ANALYTICA CHIMICA ACTA, 1995, 309 (1-3) : 35 - 45
  • [7] AN ELECTROCHEMICAL DETERMINATION OF URIC-ACID IN SERA BY A FLOW-THROUGH EQUIPMENT WITH AND WITHOUT URICASE
    JANCHEN, M
    GRUNIG, G
    BERTERMANN, K
    ANALYTICAL LETTERS PART B-CLINICAL AND BIOCHEMICAL ANALYSIS, 1985, 18 (15): : 1799 - 1820
  • [8] FLOW-THROUGH BIOSENSOR FOR SEQUENTIAL DETERMINATION OF TOTAL AND PROSTATIC ACID-PHOSPHATASE-ACTIVITY
    SANCHEZCABEZUDO, M
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 23 (01) : 9 - 15
  • [9] Chronic toxicity of hydrogen peroxide to Daphnia magna in a continuous exposure, flow-through test system
    Meinertz, Jeffery R.
    Greseth, Shari L.
    Gaikowski, Mark P.
    Schmidt, Larry J.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2008, 392 (2-3) : 225 - 232
  • [10] Plant tissue-based chemilumineseence flow biosensor for hydrogen peroxide determination in water samples
    Qu, P
    Li, BX
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (10) : 1240 - 1243