Measuring congestion with a non-invasive monitoring device in heart failure and haemodialysis: CONGEST-HF

被引:2
|
作者
Curtain, James P. [1 ,2 ]
Talebi, Atefeh [1 ]
McIntosh, Alasdair [3 ]
McConnachie, Alex [3 ]
O'Donnell, Joanne [3 ]
Welsh, Paul [1 ]
Osmanska, Joanna [1 ]
Lee, Matthew M. Y. [1 ]
Sonecki, Piotr [4 ]
Akl, Tony [5 ]
Seo, Joohyun [5 ]
Gopinathan, Venugopal [5 ]
Hurwitz, Jed [6 ]
Thiagarajan, Srikanth [5 ]
Pettit, Stephen [7 ]
Kalra, Paul R. [8 ]
Patel, Rajan K. [9 ]
Mark, Patrick B. [1 ]
Lang, Ninian N. [1 ]
McMurray, John J. V. [1 ]
Petrie, Mark C. [1 ]
Gardner, Roy S. [1 ,10 ]
Jhund, Pardeep S. [1 ,11 ]
机构
[1] Univ Glasgow, BHF Cardiovasc Res Ctr, Sch Cardiovasc & Metab Hlth, Glasgow, Scotland
[2] St James Hosp, Dublin, Ireland
[3] Univ Glasgow, Robertson Ctr Biostat, Sch Hlth & Wellbeing, Glasgow, Scotland
[4] Queen Elizabeth Univ Hosp, Dept Cardiol, Glasgow, Scotland
[5] Analog Devices Inc, Wilmington, MA USA
[6] Analog Devices Ltd, Edinburgh, Scotland
[7] Royal Papworth Hosp, Transplant Unit, Cambridge, England
[8] Portsmouth Hosp Univ NHS Trust, Cardiol, Portsmouth, England
[9] Queen Elizabeth Univ Hosp, Glasgow Renal & Transplant Unit, Glasgow, Scotland
[10] Golden Jubilee Natl Hosp, Scottish Natl Adv Heart Failure Serv, Clydebank, Scotland
[11] Univ Glasgow, British Heart Fdn Glasgow Cardiovasc Res Ctr, 126 Univ Pl, Glasgow G12 8TA, Scotland
关键词
Heart failure; Haemodialysis; Right heart catheterization; Congestion; Monitoring; CHRONIC KIDNEY-DISEASE; SPIRONOLACTONE; FINERENONE; SAFETY; EFFICACY; OUTCOMES; REGRESSION; TOPCAT; RISK;
D O I
10.1002/ejhf.3290
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims We examined the effectiveness of a novel cardiopulmonary management wearable sensor (worn for less than 5 mins) at measuring congestion and correlated the device findings with established clinical measures of congestion. Methods and results We enrolled three cohorts of patients: (1) patients with heart failure (HF) receiving intravenous diuretics in hospital; (2) patients established on haemodialysis, and (3) HF patients undergoing right heart catheterization (RHC). The primary outcomes in the respective cohorts were a Spearman correlation between (1) change in weight and change in thoracic impedance (TI) (from enrolment, 24 h after admission to discharge) in patients hospitalized for HF; (2) lung ultrasound B-lines and volume removed during dialysis with device measured TI, and (3) pulmonary capillary wedge pressure (PCWP) and sub-acoustic diastolic, third heart sound (S3) in the patients undergoing RHC. A total of 66 patients were enrolled. In HF patients (n = 25), change in weight was correlated with both change in device TI (Spearman correlation [rsp] = -0.64, p = 0.002) and change in device S3 (rsp = -0.53, p = 0.014). In the haemodialysis cohort (n = 21), B-lines and TI were strongly correlated before (rsp = -0.71, p < 0.001) and after (rsp = -0.77, p < 0.001) dialysis. Volume of fluid removed by dialysis was correlated with change in device TI (rsp = 0.49, p = 0.024). In the RHC cohort (n = 20), PCWP measured at one time point and device S3 were not significantly correlated (rsp = 0.230, p = 0.204). There were no device-related adverse events. Conclusions A non-invasive device was able to detect changes in congestion in patients with HF receiving decongestion therapy and patients having fluid removed at haemodialysis. The cardiopulmonary management device, which measures multiple parameters, is a potentially useful tool to monitor patients with HF to prevent hospitalizations.
引用
收藏
页码:1383 / 1392
页数:10
相关论文
共 50 条
  • [31] Non-Invasive Hemodynamic Assessment of Heart Failure With Preserved Ejection Fraction
    Istratoaie, Sabina
    Frost, Charlotte L.
    Donal, Erwan
    KOREAN CIRCULATION JOURNAL, 2025, 55 (03) : 165 - 184
  • [32] Merits of Non-Invasive Rat Models of Left Ventricular Heart Failure
    Alex P. Carll
    Monte S. Willis
    Robert M. Lust
    Daniel L. Costa
    Aimen K. Farraj
    Cardiovascular Toxicology, 2011, 11 : 91 - 112
  • [33] Non-Invasive Heart Failure Evaluation Using Machine Learning Algorithms
    Victor, Odeh Adeyi
    Chen, Yifan
    Ding, Xiaorong
    SENSORS, 2024, 24 (07)
  • [34] Development of biosensors for non-invasive measurements of heart failure biomarkers in saliva
    Alcacer, Albert
    Streklas, Angelos
    Baraket, Abdoullatif
    Zine, Nadia
    Errachid, Abdelhamid
    Bausells, Joan
    SMART SENSORS, ACTUATORS, AND MEMS VIII, 2017, 10246
  • [35] Patient Perspectives of a Non-Invasive Telemonitoring Tool for Patients with Heart Failure
    Sano, Motohiro
    Okada, Sho
    Majima, Tomoko
    Kobayashi, Yoshio
    SAGE OPEN NURSING, 2022, 8
  • [36] Non-Invasive Lung IMPEDANCE-Guided Preemptive Treatment in Chronic Heart Failure Patients: A Randomized Controlled Trial (IMPEDANCE-HF Trial)
    Shochat, Michael Kleiner
    Shotan, Avraham
    Blondheim, David S.
    Kazatsker, Mark
    Dahan, Iris
    Asif, Aya
    Rozenman, Yoseph
    Kleiner, Ilia
    Weinstein, Jean Marc
    Frimerman, Aaron
    Vasilenko, Lubov
    Meisel, Simcha R.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (09) : 713 - 722
  • [37] Merits of Non-Invasive Rat Models of Left Ventricular Heart Failure
    Carll, Alex P.
    Willis, Monte S.
    Lust, Robert M.
    Costa, Daniel L.
    Farraj, Aimen K.
    CARDIOVASCULAR TOXICOLOGY, 2011, 11 (02) : 91 - 112
  • [38] Assessment of Heart Sounds, Physiologic Changes, and Sleep Performance Using Non-Invasive Monitoring in a Volume Depleted Heart Failure Patient
    Hajduczok, Alexander
    Kumar, Prashanth Shyam
    Ahmed, Mohammad
    Maucione, Carly
    Varadan, Vijay
    Rai, Pratyush
    Ramasamy, Mouli
    Boehmer, John
    CIRCULATION, 2023, 148
  • [39] Non-invasive cardiac kinetic energy distribution: a new marker of heart failure with impaired ejection fraction (KINO-HF)
    De Keyzer, Eva
    Hossein, Amin
    Rabineau, Jeremy
    Morissens, Marielle
    Almorad, Alexandre
    van de Borne, Philippe
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [40] Non-invasive measurement of cardiac output in patients with chronic heart failure
    Leslie, SJ
    McKee, S
    Newby, DE
    Webb, DJ
    Denvir, MA
    BLOOD PRESSURE MONITORING, 2004, 9 (05) : 277 - 280