SIMULATING AGE RELATED RADIAL PULSES USING MAGNETO-RHEOLOGICAL FLUIDS

被引:0
作者
Eaton, Miranda [1 ]
Koo, Jeong-Hoi [1 ]
Yang, Tae-Heon [2 ]
Kim, Young-Min [3 ]
机构
[1] Miami Univ, Dept Mech & Mfg Engn MME, Oxford, OH 45056 USA
[2] Korea Natl Univ Transportat, Dept Elect Engn, Chungju Si, Chungbuk, South Korea
[3] Korea Inst Oriental Med, Digital Hlth Res Div, Daejeon, South Korea
来源
PROCEEDINGS OF ASME 2022 CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, SMASIS2022 | 2022年
关键词
radial pulses; magneto-rheological fluid; pulse simulation; pulse waveforms; ARTERIAL STIFFNESS;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study presents the design and test of a new pulse simulator capable of reproducing a wide range of radial pulses. It proposes to use a Magneto-Rheological (MR) fluid technology to shape radial pulse waveforms. The primary objective of this study is to demonstrate its feasibility of regenerating age-related human radial pulse waveforms using the proposed MR pulse simulator. The overall experimental set up includes a cam system, an MR device, an electromagnet, and sensors (laser displacement and pressure transducer). The cam system generates a base pulse waveform. This base pulse waveform is sent to an MR device which consists of a silicone tube (representing the radial artery) submerged in MR fluid. An electromagnet is placed beneath the MR fluid chamber which applies a specified magnetic field to control the MR fluid. This, in turn, enables the MR fluid to reshape the base pulse waveform to the desired pulse waveform. The mounted sensors collect data and measure the outputs for further analysis. Using this setup, a series of testing will be conducted by varying the input magnetic field with the pulse width modulation (PWM) control. PWM signals can be altered by changing the duty cycle and delay input to the electromagnet. These factors will affect the magnetic field, thus changing the MR fluid surrounding the silicone tube, and shaping the base pulse generated by the cam system. This study will then examine the pulse shaping performance of the MR device by comparing the reproduced radial pulses with those of in vivo radial pulses.
引用
收藏
页数:6
相关论文
共 13 条
[1]  
[Anonymous], Victor Pulse
[2]  
[Anonymous], Pulsatile Blood Pumps
[3]   How to standardize the pulse-taking method of traditional Chinese medicine pulse diagnosis [J].
Chung, Yu-Feng ;
Hu, Chung-Shing ;
Yeh, Cheng-Chang ;
Luo, Ching-Hsing .
COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (04) :342-349
[4]   Application of Magneto-Rheological Fluids for Investigating the Effect of Skin Properties on Arterial Tonometry Measurements [J].
Coon, Adam ;
Yang, Tae-Heon ;
Kim, Young-Mm ;
Kang, Heeshin ;
Koo, Jeong-Hoi .
FRONTIERS IN MATERIALS, 2019, 6
[5]   The fact not to ignore: Mean blood pressure is the main predictor of increased arterial stiffness in patients with systemic rheumatic diseases [J].
Cypiene, Alma ;
Dadoniene, Jolanta ;
Miltiniene, Dalia ;
Rinkuniene, Egidija ;
Rugiene, Rita ;
Stropuviene, Sigita ;
Badariene, Jolita ;
Laucevicius, Aleksandras .
ADVANCES IN MEDICAL SCIENCES, 2017, 62 (02) :223-229
[6]   Is augmentation index a good measure of vascular stiffness in the elderly? [J].
Fantin, Francesco ;
Mattocks, Adriana ;
Bulpitt, Christopher J. ;
Banya, Winston ;
Rakumar, Chakravarthi .
AGE AND AGEING, 2007, 36 (01) :43-48
[7]   Application of magneto-rheological fluids for generating a wide range of radial pulse waveforms [J].
Koo, Jeong-Hoi ;
Tantiyartyanontha, Takdanai ;
Kim, Young-Min ;
Kang, Heeshin ;
Yang, Tae-Heon .
SMART MATERIALS AND STRUCTURES, 2018, 27 (12)
[8]   Augmentation Index, Left Ventricular Contractility, and Wave Reflection [J].
Sharman, James E. ;
Davies, Justin E. ;
Jenkins, Carly ;
Marwick, Thomas H. .
HYPERTENSION, 2009, 54 (05) :1099-1105
[9]   Developing classification indices for Chinese pulse diagnosis [J].
Shu, Jian-Jun ;
Sun, Yuguang .
COMPLEMENTARY THERAPIES IN MEDICINE, 2007, 15 (03) :190-198
[10]   Cuff-less blood pressure measurement with pulse transit time: The importance of rigorous assessment [J].
van Helmond, Noud ;
Plante, Timothy B. .
JOURNAL OF CLINICAL HYPERTENSION, 2021, 23 (01) :71-72