Diagnostic accuracy and characteristics of symptomatic versus asymptomatic retained products of conception: A retrospective cohort study

被引:3
作者
Aiob, Ala [1 ,2 ,3 ]
Mikhail, Susana Mustafa [1 ,2 ]
Sgayer, Inshirah [1 ,2 ]
Kalendaryov, Alex [2 ]
Odeh, Marwan [1 ,2 ]
Lowenstein, Lior [1 ,2 ]
Sharon, Avishalom [1 ,2 ]
机构
[1] Galilee Med Ctr, Raya Strauss Wing Obstet & Gynecol, Nahariyya, Israel
[2] Bar Ilan Univ, Azrieli Fac Med, Safed, Israel
[3] Galilee Med Ctr, Dept Obstet & Gynecol, 89 Nahariya Cabri, IL-22100 Nahariyya, Israel
关键词
Retained products of conception; Hysteroscopy; Doppler flow; Endometrial thickness; TERMINATION; SONOGRAPHY; MANAGEMENT; FEATURES; WOMEN;
D O I
10.1016/j.ejogrb.2024.06.032
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the accuracy of diagnosing retained products of conception (RPOC) in symptomatic versus asymptomatic women, and to identify potential divergent ultrasound features between these groups. Methods: This retrospective study included women aged 17-50 years who underwent hysteroscopy for suspected RPOC during 2018-2021. Clinical and sonographic data were analyzed, and multivariable linear regression models employed, to examine correlations between RPOC and sonographic findings, and to compare diagnostic accuracy between symptomatic and asymptomatic women. Results: Of the 225 women included, 123 (54.7 %) were symptomatic and 102 (45.3 %) were asymptomatic. Hysteroscopy complications were more frequent in asymptomatic women. Regarding sonography, statistically significant differences were not found between the groups in endometrial thickness or uterine fluid presence, but positive Doppler flow was more common in asymptomatic than symptomatic women. Endometrial thickness >1.49 cm demonstrated diagnostic utility, with similar sensitivity and specificity in the two groups. Multivariable models revealed significant associations of RPOC presence with endometrial thickness and Doppler flow in symptomatic women. In both groups, hysteroscopy enhanced diagnostic accuracy, with higher positive predictive values and lower false-positive rates compared to ultrasound alone. Conclusion: An endometrial thickness cutoff of 1.49 cm aids diagnosing RPOC. Doppler flow enhances diagnostic value in symptomatic women. Integration of hysteroscopy improves diagnostic accuracy compared to ultrasound alone. Regular sonographic assessment for women with identifiable risk factors assists in RPOC detection irrespective of symptoms.
引用
收藏
页码:278 / 282
页数:5
相关论文
共 50 条
[21]   Postpartum retained products of conception: Retrospective analysis of the association with third stage of labor placental complications [J].
Smorgick, Noam ;
Ayashi, Nagham ;
Levinsohn-Tavor, Orna ;
Wiener, Yifat ;
Betser, Moshe ;
Maymon, Ron .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2019, 234 :108-111
[22]   Risk factors of retained products of conception after miscarriage or termination with gemeprost in the second trimester of pregnancy: a retrospective case-controlled study in Japanese population [J].
Noguchi, Tomoko ;
Shiro, Michihisa ;
Nanjo, Sakiko ;
Mizoguchi, Mika ;
Ota, Nami ;
Mabuchi, Yasushi ;
Yagi, Shigetaka ;
Minami, Sawako ;
Ino, Kazuhiko .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2022, 42 (03) :501-504
[23]   A comparison of reproductive outcomes following hysteroscopic management versus dilatation and curettage of retained products of conception [J].
Ben-Ami, Ido ;
Melcer, Yaakov ;
Smorgick, Noam ;
Schneider, David ;
Pansky, Moty ;
Halperin, Reuvit .
INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2014, 127 (01) :86-89
[24]   Acquired uterine arteriovenous malformation developing in retained products of conception: A diagnostic dilemma [J].
Goyal, Surbhi ;
Goyal, Ankur ;
Mahajan, Surbhi ;
Sharma, Shikha ;
Dev, Geeta .
JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2014, 40 (01) :271-274
[25]   Predictive factors for massive hemorrhage in women with retained products of conception: a prospective study [J].
Sonehara, Reina ;
Nakamura, Tomoko ;
Iwase, Akira ;
Nishida, Kazuki ;
Takikawa, Sachiko ;
Murakami, Mayuko ;
Yoshita, Sayako ;
Muraoka, Ayako ;
Miyake, Natsuki ;
Nakanishi, Natsuki ;
Osuka, Satoko ;
Goto, Maki ;
Kajiyama, Hiroaki .
SCIENTIFIC REPORTS, 2022, 12 (01)
[26]   Medical management of retained products of conception: A prospective observational study [J].
Schulte, Rhea L. ;
Fox, Rachael ;
Anderson, Jessica ;
Young, Nicole ;
Davis, Laura ;
Saxton, Virginia ;
Mooney, Samantha S. .
EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2023, 285 :153-158
[27]   Evaluation of the accuracy of transvaginal sonography for the assessment of retained products of conception after spontaneous abortion [J].
Chung, TKH ;
Cheung, LP ;
Sahota, DS ;
Haines, CJ ;
Chang, AMZ .
GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1998, 45 (03) :190-193
[28]   New prospects for high-intensity focused ultrasound ablation in the treatment of uterine arteriovenous fistula associated with retained products of conception: A retrospective cohort study [J].
Fu, Yunxing ;
Lei, Zengjing ;
Gong, Lin ;
Wang, Xiaoli .
MEDICINE, 2025, 104 (27)
[29]   Management of Symptomatic Vascularized Retained Products of Conception by Proximal Uterine Artery Embolization with Gelatin Sponge Torpedoes [J].
Mathieu, Eliott ;
Riethmuller, Didier ;
Delouche, Aurelie ;
Sicot, Marie ;
Teyssier, Yann ;
Finas, Mathieu ;
Guillaume, Benedicte ;
Thony, Frederic ;
Ferretti, Gilbert ;
Ghelfi, Julien .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 33 (11) :1313-1320
[30]   Retained products of conception - a retrospective analysis of 200 cases of surgical procedures for the diagnosis of residua postpartum [J].
Velebil, Petr ;
Hympanova, Lucie Hajkova ;
Herman, Hynek ;
Emingr, Michal ;
Krepelka, Petr ;
Hanacek, Jiri .
GINEKOLOGIA POLSKA, 2023, 94 (12) :967-971